CAN/CSA-C22.2 No.60730-2-5-2014(R2019)

Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for automatic electrical burner control systems (Bi-national standard with ANSI Z21.20-2014 and UL 60730-2-5)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CAN/CSA-C22.2 No.60730-2-5-2014(R2019) 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CAN/CSA-C22.2 No.60730-2-5-2014(R2019)
发布
2014年
发布单位
SCC
当前最新
CAN/CSA-C22.2 No.60730-2-5-2014(R2019)
 
 
代替标准
CSA/ANSI Z21.20:22 • CSA C22.2 No. 60730-2-5:22
被代替标准
ANSI Z21.20-07/CSA C22.2 NO. 199-07(R2011)
适用范围
1 Scope and normative references This clause of part 1 is applicable except as follows: 1.1 Replacement: This part of IEC 60730 applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles for household and similar use including heating, air conditioning and similar use. This part 2-5 is applicable to a complete burner control system and to a separate programming unit. This part 2-5 is also applicable to a separate electronic high-voltage ignition source and to a separate flame detector. Separate ignition devices (electrodes, pilot burners, etc.) are not covered by this part 2-5 unless they are submitted as part of a burner control system. Requirements for separate ignition transformers are contained in IEC 60989 . 1.1DV.1 D2 Modification of 1.1 by adding the following text to the note: Separate ignition devices (electrodes, pilot burners, etc.) are covered by this part 2-5 (Refer to Annex DVKK). Requirements for separate ignition transformers are covered in Standard for Specialty Transformers, UL 506, and CSA C22.2 No. 13, Standard for Luminous Tube Signs, Oil and Gas Burner Ignition Equipment, Cold-Cathode Interior Lighting. Throughout this part 2-5, where it can be used unambiguously, the word ²system² means ²burner control system² and ²systems² means ²burner control systems². Systems utilizing thermoelectric flame supervision are not covered by this part 2-5. 1.1DV.2 D2 Modification of 1.1 by adding the following text: Devices such as thermoelectric flame supervision, pilot burners, oxygen depletion safety shut-off systems (ODS), thermoelectric safety shut-off devices, fast-acting thermocouples, and other components are covered in Annex DVKK. 1.1.1 This part 2-5 applies to the inherent safety, to the manufacturer's declared operating values, operating times and operating sequences where such are associated with burner safety and to the testing of automatic electrical burner control systems used in, on, or in association with, burners. Requirements for specific operating values, operating times and operating sequences are given in the standards for appliances and equipment. Systems for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this part 2-5. This part 2-5 applies to systems using NTC or PTC thermistors, additional requirements for which are contained in Annex J. This part 2-5 does not apply to systems designed exclusively for industrial applications. 1.1.1DV D2 Modification of 1.1.1 by adding the following text: This part 2-5 does apply to systems designed exclusively for industrial applications. 1.1.2 This part 2-5 applies to manual controls when such are electrically and/or mechanically integral with automatic controls. Requirements for manual switches not forming part of an automatic control are contained in IEC 61058-1. Throughout this part 2-5, the word ²equipment² means ²appliance and equipment². 1.2 Replacement: This part 2-5 applies to systems with a rated voltage not exceeding 660 V and with a rated current not exceeding 63 A. 1.2DV DR Modification of 1.2 by adding the following text: The maximum control output voltage is 600 V. The maximum current is unlimited. The primary input circuit of a system shall be a two-wire, one-side-grounded system, having a voltage rating of not more than a nominal 120 volts. A switch or protective device shall be in the circuit electrically connected to the ungrounded supply conductor. 1.3 Replacement: This part 2-5 does not take into account the response value of an automatic action of a control, if such a response value is dependent upon the method of mounting the control in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer applies. This part 2-5 includes systems responsive to flame properties. 1.4 Replacement: This part 2-5 applies also to systems incorporating electronic devices, requirements for which are contained in Annex H.

CAN/CSA-C22.2 No.60730-2-5-2014(R2019)相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号