60079-7-2017
"Explosive atmospheres – Part 7: Equipment protection by increased safety ""e"" (Edition 5.1; Consolidated Reprint)"

Atmosphères explosives – Partie 7: Protection du matériel par sécurité augmentée ?e? (Edition 5.1; Consolidated Reprint)


60079-7-2017 发布历史

This part of IEC 60079 specifies the requirements for the design@ construction@ testing and marking of electrical equipment and Ex Components with type of protection increased safety ??e?? intended for use in explosive gas atmospheres. Electrical equipment and Ex Components of type of protection increased safety ??e?? are either: a) Level of Protection ??eb?? (EPL ??Mb?? or ??Gb??); or b) Level of Protection ??ec?? (EPL ??Gc??) Level of Protection ??eb?? applies to equipment or Ex Components@ including their connections@ conductors@ windings@ lamps@ and batteries; but not including semiconductors or electrolytic capacitors. NOTE 1 The use of electronic components@ such as semiconductors or electrolytic capacitors@ is excluded from Level of Protection ??eb?? as expected malfunctions could result in excessive temperatures or arcs and sparks if the internal separation distances were not applied. It is not generally practical to maintain those separation distances and maintain the function of the electronic component. Level of Protection ??ec?? applies to equipment or Ex Components@ including their connections@ conductors@ windings@ lamps@ and batteries; and also including semiconductors and electrolytic capacitors. NOTE 2 The use of electronic components@ such as semiconductors or electrolytic capacitors@ is permitted in Level of Protection ??ec?? as these are evaluated under both normal conditions and regular expected occurrences@ and are not likely to result in excessive temperatures or arcs and sparks. As the requirements for separation distances are not applied to the internal construction@ commercially available electronic components are generally suitable if the external separation distances comply. The requirements of this standard apply to both Levels of Protection unless otherwise stated. For Level of Protection ??eb??@ this standard applies to electrical equipment where the rated voltage does not exceed 11 kV r.m.s.@ a.c. or d.c. For Level of Protection ??ec??@ this standard applies to electrical equipment where the rated voltage does not exceed 15 kV r.m.s.@ a.c. or d.c. NOTE 3 Short circuit currents flowing through increased safety connections of mains circuits are not considered to create a significant risk of ignition of an explosive gas atmosphere due to movement of connections as a result of mechanical stresses created by the short circuit current. Normal industrial standards require that the effects of short time high currents on the security of connections be considered. The presence of the explosive gas atmosphere does not adversely affect the security of the connection. NOTE 4 Any short term thermal excursions that occur as a result of electrical current excursions above normal rated currents@ such as those that occur during the starting of motors@ are not considered to create a significant risk of ignition of an explosive gas atmosphere due to the relatively short duration of the event and the convection that occurs during the event. NOTE 5 High-voltage connections and associated wiring (above 1 kV) can be susceptible to increased partial discharge activity that could be a source of ignition. Increased spacings to earthed surfaces or other connections and provision of suitable high-voltage stress relief for the terminations are typically provided. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0@ the requirement of this standard takes precedence.

60079-7-2017由IEC - International Electrotechnical Commission 发布于 2017-08-01,并于 2017-08-08 实施。

60079-7-2017 发布之时,引用了标准

  • 496 *2017-09-05 更新

* 在 60079-7-2017 发布之后有更新,请注意新发布标准的变化。

60079-7-2017的历代版本如下:

  • 1969年01月01日 60079-7-1969 "Electrical Apparatus for Explosive Gas Atmospheres Part 7: Construction and test of electrical apparatus@ type of protection ""E"" (Edition 1.0)"
  • 1990年01月01日 60079-7-1990
  • 2001年11月01日 60079-7-2001 Materiel Electrique Pour Atmospheres Explosives Gazeuses - Partie 7: Securite Augmentee ((E)) (Edition 3.0)
  • 2002年12月02日 60079-7-2002
  • 2006年07月01日 60079-7-2006 "Atmosphères explosives – Partie 7: Protection de l'équipement par sécurité augmentée ""e"" (Edition 4.0)"
  • 2007年03月09日 60079-7-2007
  • 2008年10月15日 60079-7-2008
  • 2015年06月01日 60079-7-2015
  • 2017年08月01日 60079-7-2017 "Explosive atmospheres – Part 7: Equipment protection by increased safety ""e"" (Edition 5.1; Consolidated Reprint)"

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 60079-7-2017 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
60079-7-2017
发布日期
2017年08月01日
实施日期
2017年08月08日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
496
适用范围
This part of IEC 60079 specifies the requirements for the design@ construction@ testing and marking of electrical equipment and Ex Components with type of protection increased safety ??e?? intended for use in explosive gas atmospheres. Electrical equipment and Ex Components of type of protection increased safety ??e?? are either: a) Level of Protection ??eb?? (EPL ??Mb?? or ??Gb??); or b) Level of Protection ??ec?? (EPL ??Gc??) Level of Protection ??eb?? applies to equipment or Ex Components@ including their connections@ conductors@ windings@ lamps@ and batteries; but not including semiconductors or electrolytic capacitors. NOTE 1 The use of electronic components@ such as semiconductors or electrolytic capacitors@ is excluded from Level of Protection ??eb?? as expected malfunctions could result in excessive temperatures or arcs and sparks if the internal separation distances were not applied. It is not generally practical to maintain those separation distances and maintain the function of the electronic component. Level of Protection ??ec?? applies to equipment or Ex Components@ including their connections@ conductors@ windings@ lamps@ and batteries; and also including semiconductors and electrolytic capacitors. NOTE 2 The use of electronic components@ such as semiconductors or electrolytic capacitors@ is permitted in Level of Protection ??ec?? as these are evaluated under both normal conditions and regular expected occurrences@ and are not likely to result in excessive temperatures or arcs and sparks. As the requirements for separation distances are not applied to the internal construction@ commercially available electronic components are generally suitable if the external separation distances comply. The requirements of this standard apply to both Levels of Protection unless otherwise stated. For Level of Protection ??eb??@ this standard applies to electrical equipment where the rated voltage does not exceed 11 kV r.m.s.@ a.c. or d.c. For Level of Protection ??ec??@ this standard applies to electrical equipment where the rated voltage does not exceed 15 kV r.m.s.@ a.c. or d.c. NOTE 3 Short circuit currents flowing through increased safety connections of mains circuits are not considered to create a significant risk of ignition of an explosive gas atmosphere due to movement of connections as a result of mechanical stresses created by the short circuit current. Normal industrial standards require that the effects of short time high currents on the security of connections be considered. The presence of the explosive gas atmosphere does not adversely affect the security of the connection. NOTE 4 Any short term thermal excursions that occur as a result of electrical current excursions above normal rated currents@ such as those that occur during the starting of motors@ are not considered to create a significant risk of ignition of an explosive gas atmosphere due to the relatively short duration of the event and the convection that occurs during the event. NOTE 5 High-voltage connections and associated wiring (above 1 kV) can be susceptible to increased partial discharge activity that could be a source of ignition. Increased spacings to earthed surfaces or other connections and provision of suitable high-voltage stress relief for the terminations are typically provided. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0@ the requirement of this standard takes precedence.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号