80601-2-30-2018 Medical electrical equipment – Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers (Edition 2.0)
Appareils électromédicaux – Partie 2-30: Exigences particulières pour la sécurité de base et les performances essentielles des sphygmomanomètres non invasifs automatiques (Edition 2.0)
Medical electrical equipment – Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers (Edition 2.0) 是非强制性国家标准,您可以免费下载前三页
Clause 1 of the general standard2 applies@ except as follows: Replacement: This part of the 80601 International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of AUTOMATED SPHYGMOMANOMETERS@ hereafter referred to as ME EQUIPMENT@ which by means of an inflatable CUFF@ are used for non-continuous indirect estimation of the BLOOD PRESSURE without arterial puncture. NOTE 1 Equipment that performs indirect DETERMINATION of the BLOOD PRESSURE without arterial puncture does not directly measure the BLOOD PRESSURE. It only estimates the BLOOD PRESSURE. This document specifies requirements for the BASIC SAFETY and ESSENTIAL PERFORMANCE for this ME EQUIPMENT and its ACCESSORIES@ including the requirements for the accuracy of a DETERMINATION. This document covers automatic electrically-powered ME EQUIPMENT used for the intermittent@ indirect estimation of the BLOOD PRESSURE without arterial puncture@ including BLOOD PRESSURE monitors for the HOME HEALTHCARE ENVIRONMENT. Requirements for indirect estimation of the BLOOD PRESSURE without arterial puncture ME EQUIPMENT with an electrically-powered PRESSURE TRANSDUCER and/or displays used in conjunction with a stethoscope or other manual methods for determining BLOOD PRESSURE (NON-AUTOMATED SPHYGMOMANOMETERS) are specified in document ISO 81060-1 [2]. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only@ or to ME SYSTEMS only@ the title and content of that clause or subclause will say so. If that is not the case@ the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS@ as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in 201.11 and 201.105.3.3@ as well as 7.2.13 and 8.4.1 of IEC 60601-1:2005. NOTE 2 See also 4.2 of IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012. 2 The general standard is IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012@ Medical electrical equipment ?C Part 1: General requirements for basic safety and essential performance.