IEC 62236-5:2018
铁路应用《电磁兼容性》第5部分:固定供电装置和设备的辐射和抗扰度(3.0版)

Railway applications – Electromagnetic compatibility – Part 5: Emission and immunity of fixed power supply installations and apparatus (Edition 3.0)


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:IEC 62236-5:2018 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

IEC 62236-5:2018



标准号
IEC 62236-5:2018
发布
2018年
发布单位
IEC - International Electrotechnical Commission
当前最新
IEC 62236-5:2018
 
 
适用范围
This part of IEC 62236 applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations for power supply. This includes the power feed to the apparatus@ the apparatus itself with its protective control circuits@ trackside items such as switching stations@ power autotransformers@ booster transformers@ substation power switchgear and power switchgear to other longitudinal and local supplies. Filters operating at railway system voltage (for example@ for harmonic suppression or power factor correction) are not included in this document since each site has special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required@ these will appear in the specification for the equipment. If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators@ e.g. transponder systems)@ then the radiated emission requirements in this document are not intended to be applicable to the intentional transmission from a radiotransmitter as defined by the ITU. The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified. Emission and immunity limits are given for items of apparatus which are situated: a) within the boundary of a substation which delivers electric power to a railway; b) beside the track for the purpose of controlling or regulating the railway power supply@ including power factor correction; c) along the track for the purpose of supplying electrical power to the railway other than by means of the conductors used for contact current collection@ and associated return conductors. Included are high voltage feeder systems within the boundary of the railway which supply substations at which the voltage is reduced to the railway system voltage; d) beside the track for controlling or regulating electric power supplies to ancillary railway uses. This category includes power supplies to marshalling yards@ maintenance depots and stations; e) various other non-traction power supplies from railway sources which are shared with railway traction. The immunity levels given in this document apply for: ?C vital equipment such as protection devices; ?C equipment having connections to the traction power conductors; ?C apparatus inside the 3 m zone; ?C ports of apparatus inside the 10 m zone with connection inside the 3 m zone; ?C ports of apparatus inside the 10 m zone with cable length > 30 m. Apparatus and systems which are in an environment which can be described as residential@ commercial or light industry@ even when placed within the physical boundary of the railway substation@ comply with IEC 61000-6-1 for immunity and IEC 61000-6-3 for emission requirements. Excluded from the immunity requirements of this document is power supply apparatus which is intrinsically immune to the tests defined in Table 1 to Table 6 of this document. NOTE An example is an 18 MVA 230 kV to 25 kV power supply transformer. These specific provisions are used in conjunction with the general provisions in IEC 62236-1.

IEC 62236-5:2018相似标准


推荐


谁引用了IEC 62236-5:2018 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号