GSO IEC 62893-1:2022
额定电压0.6/1 kV及以下电动汽车充电电缆 第1部分:一般要求

Charging cables for electric vehicles for rated voltages up to and including 0,6/1 kV - Part 1: General requirements


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO IEC 62893-1:2022 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO IEC 62893-1:2022
发布
2022年
发布单位
GSO
当前最新
GSO IEC 62893-1:2022
 
 
适用范围
IEC 62893-1:2017+A1:2020 specifies construction, dimensions and test requirements for cables with extruded insulation and sheath having a voltage rating of up to and including 0,6/1 kV AC or up to and including 1 500 V DC for flexible applications under harsh conditions for the power supply between the electricity supply point of the charging station and the electric vehicle (EV). The EV charging cable is intended to supply power and, if needed, communication (for details see the IEC 62196 series and IEC 61851-1) to an EV or plug-in hybrid vehicle (PHEV). The charging cables are applicable for charging modes 1 to 4 of IEC 61851-1. Ordinary duty cables with rated voltage 300/500 V are only permitted for charging mode 1 of IEC 61851-1. Maximum conductor temperature for the cables in this part of IEC 62893 is 90 ºC. The particular types of cables are specified in IEC 62893-3 (modes 1 to 3 for AC charging) and in the future IEC 62893-4 (mode 4 for DC charging). These parts are collectively referred to hereafter as “the particular specifications”. The test methods specified are given in IEC 62893-2, IEC 60245-2, IEC 60332-1-2, IEC 62821-1:2015, Annex B, and in the relevant parts of IEC 60811, as listed in the normative references. This consolidated version consists of the first edition (2017) and its amendment 1 (2020). Therefore, no need to order amendment in addition to this publication.

GSO IEC 62893-1:2022相似标准


推荐

电线电缆完整性燃烧试验机符合的标准

1、GB/T19216.11-2003/IEC60331-11:1999《在火焰条件下电缆和光缆的线路完整性试验11部分:试验装置---火焰温度不低于750℃的单独供火》设计。2、GB/T19216.21-2003/IEC60331-21:1999《在火焰条件下电缆和光缆的线路完整性试验21部分:试验步骤和要求----额定电压0.6/1.0kv以下电缆》。...

直流高压发生器在特殊场合使用时候如何设定电压

它广泛用于电气设备直流耐压试验和泄漏电流试验,并且特别设置了测试氧化锌避雷器1mA下的电压U1mA0.75U1mA下的泄漏电流功能。仪器一般满足工频情况下220KV电压等级以下电缆直流耐压试验的,但有些特殊场合下,有些电缆、电气的额定电压等级是有特殊要求的,比如我国煤炭行业井下电缆、电气的电压就与地面额定压不同,只有6KV,那么遇到这种情况,如何为直流高压发生器设定试验电压呢?...

直流高压发生器在特殊场合使用时如何设定电压

它广泛用于电气设备直流耐压试验和泄漏电流试验,并且特别设置了测试氧化锌避雷器1mA下的电压U1mA0.75U1mA下的泄漏电流功能。仪器一般满足工频情况下220KV电压等级以下电缆直流耐压试验的,但有些特殊场合下,有些电缆、电气的额定电压等级是有特殊要求的,比如我国煤炭行业井下电缆、电气的电压就与地面额定压不同,只有6KV,那么遇到这种情况,如何为直流高压发生器设定试验电压呢?...

直流高压发生器在特殊场合使用时该如何设定电压

以交联聚乙烯电缆为例,上述的6KV电缆,所需要的直流试验电压为25KV,持续时间5分钟。  一般试验,需要从40%的足额试验电压开始缓慢提升电压至足额电压,持续5min。如果是不满一年的新电缆线路,停电只一个月的。可以做50%规定试验电压,持续1min,停电一年的需要按照一般性试验要求做。  具体不同电缆的试验电压和加压时间规定,具体的试验要求,在电力电缆预防性试验规程中都有详细说明。  ...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号