60966-2-5-2016 Radio frequency and coaxial cable assemblies – Part 2-5: Detail specification for cable assemblies for radio and TV receivers – Frequency range 0 MHz to 1 000 MHz@ IEC 61169-2 connectors (Edition 4.0)
Cordons coaxiaux et cordons pour fréquences radioélectriques – Partie 2-5: Spécification particulière pour cordons de connexion de récepteurs radio ou TV – Plage de fréquences de 0 MHz à 1 000 MHz@ connecteurs IEC 61169-2 (Edition 4.0)
Radio frequency and coaxial cable assemblies – Part 2-5: Detail specification for cable assemblies for radio and TV receivers – Frequency range 0 MHz to 1 000 MHz@ IEC 61169-2 connectors (Edition 4.0) 是非强制性国家标准,您可以免费下载前三页
INTRODUCTION This part of IEC 60966 is a detail specification which applies to flexible coaxial cables described in the IEC 61196 series. It relates to cable assemblies for radio and TV receivers@ and in particular to the cable assemblies subfamily 9@52 (see IEC 61169-2). These cable assemblies are used as described in IEC 60728-4. This part of IEC 60966 gives subfamily requirements and severities which shall be applied. Under qualification approval@ the qualification will be conducted in accordance with 12.2 of IEC 60966-2-1:2008 taking into account the specified variants. Only the tests whose results might depend on the variants will be repeated. Under capability approval@ the qualification will be conducted on the relating CQCs (capability qualifying components) as defined in 12.3 of IEC 60966-2-1:2008 and described in the CM (capability manual). Unless otherwise specified in the CM@ only lot-by-lot tests from groups Ba and Eb will be conducted on delivered products@ all other tests will be performed on CQCs as defined in 12.3 of IEC 60966-2-1:2008 and described in the CM.