GSO IEC/TR 61641:2014
封闭式低压切割、连接和控制设备组件内部故障电弧条件下的试验手册

Enclosed low-voltage switchgear and controlgear assemblies - Guide for testing under conditions of arcing due to internal fault


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO IEC/TR 61641:2014 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO IEC/TR 61641:2014
发布
2014年
发布单位
GSO
当前最新
GSO IEC/TR 61641:2014
 
 
适用范围
This technical report gives guidance on the method of testing of ASSEMBLIES under conditions of arcing in air due to an internal fault. The purpose of this test is to assess the ability of the ASSEMBLY to limit the risk of personal injury, damage of ASSEMBLIES and its suitability for further service as a result of an internal arcing fault. The test procedure given in this technical report applies only: – to enclosed, floor-standing or wall-mounted low-voltage switchgear and controlgear assemblies according to IEC 61439-2 (power switchgear and controlgear assemblies – PSC ASSEMBLIES); NOTE This technical report can be used as a reference for arc fault tests of other products, but adaptations of the test procedures and acceptance criteria can apply taking into account the specifics of such other ASSEMBLIES or products. – to situations when doors and covers of the ASSEMBLY are closed and correctly secured. When tests under different or more severe conditions are agreed between the user and the manufacturer, this technical report can be used as a guide. The test procedure given in this technical report takes into consideration: – the effects of the internal overpressure acting on covers, doors, etc.; – the thermal effects of the arc or its roots on the enclosures and of ejected hot gases and glowing particles. The test procedure given in this technical report does not cover: – other effects which can constitute a risk, such as toxic gases and loud noises; – conditions during maintenance work, open doors or similar; – access to the top and bottom of the ASSEMBLY. This is a voluntary test made at the discretion of the manufacturer.

GSO IEC/TR 61641:2014相似标准


推荐

针焰试验参数及适用

   针焰试验仪适用于照明、低压电器、家用电器、机床电器、电机、电动工具、电子仪器、电工仪表、电气连接件、辅件等电工电子设备及其部件、组件研究、生产质检部门;    也适用于绝缘材料、工程塑料或其它固体可燃材料行业。   ...

液相自动进样器

2重新启动部件之前,需要对外接设备泄漏故障进行维修。3检查外接仪器是否满足关机条件。4检查真空脱气器出现故障原因。请参阅脱气机或包含内置脱气机 1260泵《服务手册》。Remote TimeoutError ID: 0070遥控超时1 连接到遥控线上某台仪器处于未就绪状态。2 遥控电缆出现故障3 显示未就绪状态仪器中存在有故障元件。...

gcs是什么意思

④  设计紧凑:以较小空间容纳较多功能单元。  ⑤  结构件通用性强、组装灵活,以E=25mm为模数,结构及抽出式单元可以任意组合,以满足系统设计需要。  ⑥  母线用高强度阻燃型、高绝缘强度塑料功能板保护,具有抗故障电弧性能,使运行维修安全可靠。  ⑦  各种大小抽屉机械联锁机构符合标准规定,有连接试验、分离三个明显位置,安全可靠。  ...

干货 | 通用质量特性(“六性”)工作开展 ——定性指标的分析与验证

三态总线控制线应是外部可达;5)大反馈环回路、长逻辑通道、长计数器(超过8位)最好应在输入与输出连接器处或通过外部控制逻辑信号来断开;6)测试点应能提供控制输入与输出或信号输出以断开反馈环回路、计数器通道。4.5.8.测试观测性要求1)应提供测试点、数据通路电路,使测试系统能够观测被测单元内部故障状态,用于故障检测隔离。...