1 Scope
This document specifies flame and electrothermal atomic absorption spectrometric methods
for the determination of the time-weighted average mass concentration of particulate
lead and lead compounds in workplace air.
These methods are typically applicable to personal sampling of the inhalable fraction
of airborne particles, as defined in ISO 7708, and to static (area) sampling. It can be applied to other health-related fractions
as required.
The sample dissolution procedure specifies hot plate or microwave assisted digestion, or ultrasonic extraction
(see 11.2). The use of an alternative, more vigorous dissolution procedure is necessary when
it is desired to extract lead from compounds present in the test atmosphere that are
insoluble using the dissolution procedures described herein (see Clause 5).
The flame atomic absorption method is applicable to the determination of masses of
approximately 1 µg to 200 µg of lead per sample, without dilution [ 1 ] . The electrothermal atomic absorption method is applicable to the determination of
masses of approximately 0,01 µg to 0,5 µg of lead per sample, without dilution [ 1 ] .
The ultrasonic extraction procedure has been validated for the determination of masses
of approximately 20 µg to 100 µg of lead per sample, for laboratory-generated lead
fume air filter samples [ 2 ] .
The concentration range for lead in air for which this procedure is applicable is
determined in part by the sampling procedure selected by the user (see 10.1).