61000-6-2-2005
Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for industrial environments (Edition 2.0)

Compatibilité électromagnétique (CEM) – Partie 6-2: Normes génériques – Immunité pour les environnements industriels (Edition 2.0)


61000-6-2-2005 发布历史

This part of IEC 61000 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in industrial environments@ as described below. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified.This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists.This standard applies to apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant@ and intended to operate in or in proximity to industrial locations@ as described below. This standard applies also to apparatus which is battery operated and intended to be used in industrial locations.The environments encompassed by this standard are industrial@ both indoor and outdoor.Industrial locations are in addition characterised by the existence of one or more of the following:?C industrial@ scientific and medical (ISM) apparatus (as defined in CISPR 11);?C heavy inductive or capacitive loads are frequently switched;?C currents and associated magnetic fields are high.The object of this standard is to define immunity test requirements for apparatus defined in the scope in relation to continuous and transient@ conducted and radiated disturbances@ including electrostatic discharges.The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at industrial locations. The levels do not@ however@ cover extreme cases@ which may occur at any location@ but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard@ but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements.NOTE 1 Information on other disturbance phenomena is given in IEC 61000-4-1.Test requirements are specified for each port considered.NOTE 2 Safety considerations are not covered by this standard.NOTE 3 In special cases@ situations will arise where the level of disturbances may exceed the levels specified in this standard e.g. where an apparatus is installed in proximity to ISM equipment as defined in CISPR 11 or where a hand-held transmitter is used in close proximity to an apparatus. In these instances@ special mitigation measures may have to be employed.NOTE 4 The industrial environment may be changed by special mitigation measures. Where such measures can be shown to produce an electromagnetic environment equivalent to the residential@ commercial or light-industrial environment@ then the generic standard for this environment@ or the relevant product standard@ should be applied.

61000-6-2-2005由IEC - International Electrotechnical Commission 发布于 2005-01-01,并于 2016-08-12 实施。

61000-6-2-2005的历代版本如下:

  • 1999年01月01日 61000-6-2-1999 Electromagnetic Compatibility (EMC) - Part 6-2: Generic Standards - Immunity for Industrial Environments (Edition 1.0)
  • 2005年01月01日 61000-6-2-2005 Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for industrial environments (Edition 2.0)

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 61000-6-2-2005 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
61000-6-2-2005
发布日期
2005年01月01日
实施日期
2016年08月12日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
38
适用范围
This part of IEC 61000 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in industrial environments@ as described below. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified.This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists.This standard applies to apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant@ and intended to operate in or in proximity to industrial locations@ as described below. This standard applies also to apparatus which is battery operated and intended to be used in industrial locations.The environments encompassed by this standard are industrial@ both indoor and outdoor.Industrial locations are in addition characterised by the existence of one or more of the following:?C industrial@ scientific and medical (ISM) apparatus (as defined in CISPR 11);?C heavy inductive or capacitive loads are frequently switched;?C currents and associated magnetic fields are high.The object of this standard is to define immunity test requirements for apparatus defined in the scope in relation to continuous and transient@ conducted and radiated disturbances@ including electrostatic discharges.The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at industrial locations. The levels do not@ however@ cover extreme cases@ which may occur at any location@ but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard@ but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements.NOTE 1 Information on other disturbance phenomena is given in IEC 61000-4-1.Test requirements are specified for each port considered.NOTE 2 Safety considerations are not covered by this standard.NOTE 3 In special cases@ situations will arise where the level of disturbances may exceed the levels specified in this standard e.g. where an apparatus is installed in proximity to ISM equipment as defined in CISPR 11 or where a hand-held transmitter is used in close proximity to an apparatus. In these instances@ special mitigation measures may have to be employed.NOTE 4 The industrial environment may be changed by special mitigation measures. Where such measures can be shown to produce an electromagnetic environment equivalent to the residential@ commercial or light-industrial environment@ then the generic standard for this environment@ or the relevant product standard@ should be applied.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号