61000-4-5-2005
Compatibilité électromagnétique (CEM) – Partie 4-5: Techniques d'essai et de mesure – Essai d'immunité aux ondes de choc (Edition 2.0)

Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test (Edition 2.0)


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:61000-4-5-2005 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 61000-4-5-2005 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
61000-4-5-2005
发布日期
2005年11月01日
实施日期
2014年05月17日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
IEC - International Electrotechnical Commission
引用标准
104
适用范围
This part of IEC 61000 relates to the immunity requirements@ test methods@ and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to surges. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. NOTE As described in IEC Guide 107@ this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107@ the IEC product committees are responsible for determining whether this immunity test standard should be applied or not@ and if applied@ they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products.This standard defines: ?C a range of test levels; ?C test equipment; ?C test setups; ?C test procedures. The task of the described laboratory test is to find the reaction of the EUT under specified operational conditions@ to surge voltages caused by switching and lightning effects at certain threat levels. It is not intended to test the capability of the EUT's insulation to withstand high-voltage stress. Direct injections of lightning currents@ i.e@ direct lightning strikes@ are not considered in this standard.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号