UL 1604-1994
2类1级、2级和3级危险场所用电气设备

UL Standard for Safety Electrical Equipment for Use in Class I and II, Division 2, and Class III Hazardous (Classified) Locations Third Edition;Reprinted With Revisions Through and Including 2/3/2004


UL 1604-1994 发布历史

1.1 These requirements apply to equipment, circuits, or components intended for use in Class I, Groups A, B, C, and D, Division 2, hazardous (classified) locations; Class II, Groups F and G, Division 2, hazardous (classified) locations; and Class III, Divisions 1 and 2, hazardous (classified) locations as defined in Article 500 of the National Electrical Code, NFPA 70. 1.2 The equipment shall be capable of being installed in accordance with the requirements in the National Electrical Code, NFPA 70.Battery-powered portable equipment need not comply with this requirement 1.3 The requirements cover Class I, Division 2 electrical equipment, or parts of such equipment, in which the circuits and components under intended operating conditions are incapable of causing ignition of the specified flammable gas- or vapor-air mixture. 1.4 These requirements cover Class II, Division 2, and Class III, Division 1 and Division 2 equipment that is constructed to reduce or exclude the entrance of dust. 1.5 These requirements apply only to equipment for use under the following atmospheric conditions.a)An ambient temperature of 5 to 40℃ (41 to 104℉),b)An oxygen concentration not greater than 21 percent, and c)A nominal barometric pressure of one atmosphere.1.6 These requirements cover portable battery-powered equipment, other than flashlights and lanterns, for Class I and Class II, Division 2, and Class III, Divisions 1 and 2 hazardous (classified) locations. 1.6.1 These requirements also cover equipment, circuits, or components intended for installation and use in Class I, Zone 2, Groups IIA, IIB, and IIC hazardous (classified) locations. 1.7 These requirements do not cover electric lighting fixtures for use in Division 2 hazardous (classified) locations which are covered in the Standard for Electric Lighting Fixtures for Use in Hazardous (Classified) Locations, UL 844. 1.8 These requirements do not cover electric motors, electric heaters, heat tracing cables and similar heat-producing devices, or equipment with cathode ray tubes, for use in Division 2 locations. Such products are covered under separate requirements. 1.9 These requirements do not cover explosion-proof, dust-ignition-proof, or intrinsically-safe methods of protection for electrical equipment or parts thereof. Such methods of protection are considered acceptable for Division 2 hazardous locations. The requirements are covered in other standards. 1.10 A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.

UL 1604-1994由美国保险商实验所 US-UL 发布于 1994-04-28。

UL 1604-1994 在中国标准分类中归属于: K35 防爆电器,在国际标准分类中归属于: 29.260.20 易爆环境用电气设备。

UL 1604-1994的历代版本如下:

  • 2012年 UL 1604 BULLETIN-2012 用于 I 类和 II 类 Division 2 和 III 类危险(分类)场所的安全电气设备的 UL 标准
  • 2005年 UL 1604 BULLETINS-2005 用于 I 类和 II Division 2 和 III 类危险(分类)场所的安全电气设备的 UL 标准(12/12/2005(2p);08/01/2005(2p))
  • 2003年 UL 1604 BULLETINS-2003
  • 1994年 UL 1604-1994 2类1级、2级和3级危险场所用电气设备
标准号
UL 1604-1994
发布
1994年
发布单位
美国保险商实验所
替代标准
UL 1604 BULLETINS-2003
当前最新
UL 1604 BULLETIN-2012
 
 
适用范围
1.1 These requirements apply to equipment, circuits, or components intended for use in Class I, Groups A, B, C, and D, Division 2, hazardous (classified) locations; Class II, Groups F and G, Division 2, hazardous (classified) locations; and Class III, Divisions 1 and 2, hazardous (classified) locations as defined in Article 500 of the National Electrical Code, NFPA 70. 1.2 The equipment shall be capable of being installed in accordance with the requirements in the National Electrical Code, NFPA 70.Battery-powered portable equipment need not comply with this requirement 1.3 The requirements cover Class I, Division 2 electrical equipment, or parts of such equipment, in which the circuits and components under intended operating conditions are incapable of causing ignition of the specified flammable gas- or vapor-air mixture. 1.4 These requirements cover Class II, Division 2, and Class III, Division 1 and Division 2 equipment that is constructed to reduce or exclude the entrance of dust. 1.5 These requirements apply only to equipment for use under the following atmospheric conditions.a)An ambient temperature of 5 to 40℃ (41 to 104℉),b)An oxygen concentration not greater than 21 percent, and c)A nominal barometric pressure of one atmosphere.1.6 These requirements cover portable battery-powered equipment, other than flashlights and lanterns, for Class I and Class II, Division 2, and Class III, Divisions 1 and 2 hazardous (classified) locations. 1.6.1 These requirements also cover equipment, circuits, or components intended for installation and use in Class I, Zone 2, Groups IIA, IIB, and IIC hazardous (classified) locations. 1.7 These requirements do not cover electric lighting fixtures for use in Division 2 hazardous (classified) locations which are covered in the Standard for Electric Lighting Fixtures for Use in Hazardous (Classified) Locations, UL 844. 1.8 These requirements do not cover electric motors, electric heaters, heat tracing cables and similar heat-producing devices, or equipment with cathode ray tubes, for use in Division 2 locations. Such products are covered under separate requirements. 1.9 These requirements do not cover explosion-proof, dust-ignition-proof, or intrinsically-safe methods of protection for electrical equipment or parts thereof. Such methods of protection are considered acceptable for Division 2 hazardous locations. The requirements are covered in other standards. 1.10 A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire or of electric shock or injury to persons shall be evaluated using appropriate additional component and end-product requirements to maintain the level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this standard does not comply with this standard. Revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.