IEC/TR3 61000-3-6-1996
电磁兼容性(EMC) 第3部分:限值 第6节:中高压电力系统中畸变负荷发射限值的评估 基础EMC出版物

Electromagnetic compatibility (EMC) - Part 3: Limits - Section 6: Assessment of emission limits for distorting loads in MV and HV power systems - Basic EMC publication


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC/TR3 61000-3-6-1996 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC/TR3 61000-3-6-1996 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 




购买全文,请联系:


标准号
IEC/TR3 61000-3-6-1996
发布日期
1996年10月
实施日期
废止日期
2008-02
中国标准分类号
L06
国际标准分类号
33.100.01
发布单位
IX-IEC
代替标准
IEC/TR 61000-3-6-2008
适用范围
This technical report outlines principles which are intended to be used as the basis for determining the requirements for connecting large distorting loads (producing harmonics and/or interharmonics) to public power systems. The primary objective is to provide guidance for engineering practices which will ensure adequate service quality for all connected consumers. Since the guidelines outlined in this report are necessarily based on certain simplifying assumptions, there is no guarantee that this approach will always provide the optimum solution for all harmonic problems. The recommended approach should be used with flexibility and judgment as far as engineering is concerned, when applying the given assessment procedures in full or in part. The final decision regarding the connection of distorting installations will always rest with the utility. Problems related to harmonics fall into two basic categories: - The harmonic currents are injected into the supply network by converters and other harmonic sources. Both harmonic currents and resulting voltages can be considered as conducted phenomena. The objective of this report is to limit actual harmonic voltages on supply systems to levels (compatibility levels) that will not result in adverse effects on sensitive equipment. Since the harmonic voltages result from harmonic currents and impedances, this involves limiting the harmonic currents injected into the system. - The harmonic currents in the range 50 Hz to 5 kHz may induce interference into communication systems. This phenomenon is more pronounced at higher order harmonic frequencies because of increased coupling between the circuits and because of the higher sensitivity of the communication circuits in the audible range. This report primarily focuses on controlling or limiting harmonic voltages and their effects, but a clause is included to address communication interference. NOTES 1 The load is to be understood as the complete consumer's installation. 2 This report uses the following terms for system voltage: - low voltage (LV) refers to Un < 1 kV; - medium voltage (MV) refers to 1 kV < Un < 35 kV; - high voltage (HV) refers to 35 kV < Un < 230 kV; - extra high voltage (EHV) refers to 230 kV < Un. In the context of this report, the function of the network is more important than its nominal voltage. For example, a HV system used for distribution may be given a "planning level" (see clause 3) which is situated between those of MV and HV systems.

IEC/TR3 61000-3-6-1996系列标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号