封闭管道中流体流量的测量 流体脉动对流量测量仪器影响的指南

Measurement of fluid flow in closed conduits - Guidelines on the effects of flow pulsations on flow-measurement instruments


ISO/TR 3313-1998 发布历史

This Technical Report defines pulsating flow, compares it with steady flow, indicates how it can be detected, and describes the effects it has on orifice plates, nozzles or Venturi tubes, turbine and vortex flowmeters when these devices are being used to measure fluid flow in a pipe. These particular flowmeter types feature in this Technical Report because they are amongst those types most susceptible to pulsation effects. Methods for correcting the flowmeter output signal for errors produced by these effects are described for those flowmeter types for which this is possible. When correction is not possible, measures to avoid or reduce the problem are indicated. Such measures include the installation of pulsation damping devices and/or choice of a flowmeter type which is less susceptible to pulsation effects. This Technical Report applies to flow in which the pulsations are generated at a single source which is situated either upstream or downstream of the primary element of the flowmeter. Its applicability is restricted to conditions where the flow direction does not reverse in the measuring section but there is no restriction on the waveform of the flow pulsation. The recommendations within this Technical Report apply to both liquid and gas flows although with the latter the validity may be restricted to gas flows in which the density changes in the measuring section are small as indicated for the particular type of flowmeter under discussion.

ISO/TR 3313-1998由国际标准化组织 IX-ISO 发布于 1998-08。

ISO/TR 3313-1998 在中国标准分类中归属于: A42 物理学与力学,在国际标准分类中归属于: 17.120.10 封闭管道中流量的测量。

ISO/TR 3313-1998的历代版本如下:

  • 1992年07月 ISO/TR 3313-1992 用节流孔板、喷嘴和杜利管法测量管道中的脉动流量
  • 1998年08月 ISO/TR 3313-1998 封闭管道中流体流量的测量 流体脉动对流量测量仪器影响的指南
  • 1970年01月 ISO/TR 3313-2018 封闭管道中流体流量的测量 流体脉动对流量测量仪器影响的指南

ISO/TR 3313-1998 封闭管道中流体流量的测量 流体脉动对流量测量仪器影响的指南 于 2018-0301 变更为 ISO/TR 3313-2018 封闭管道中流体流量的测量 流体脉动对流量测量仪器影响的指南。

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ISO/TR 3313-1998 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ISO/TR 3313-1998
发布日期
1998年08月
实施日期
废止日期
中国标准分类号
A42
国际标准分类号
17.120.10
发布单位
IX-ISO
代替标准
ISO/TR 3313-2018
适用范围
This Technical Report defines pulsating flow, compares it with steady flow, indicates how it can be detected, and describes the effects it has on orifice plates, nozzles or Venturi tubes, turbine and vortex flowmeters when these devices are being used to measure fluid flow in a pipe. These particular flowmeter types feature in this Technical Report because they are amongst those types most susceptible to pulsation effects. Methods for correcting the flowmeter output signal for errors produced by these effects are described for those flowmeter types for which this is possible. When correction is not possible, measures to avoid or reduce the problem are indicated. Such measures include the installation of pulsation damping devices and/or choice of a flowmeter type which is less susceptible to pulsation effects. This Technical Report applies to flow in which the pulsations are generated at a single source which is situated either upstream or downstream of the primary element of the flowmeter. Its applicability is restricted to conditions where the flow direction does not reverse in the measuring section but there is no restriction on the waveform of the flow pulsation. The recommendations within this Technical Report apply to both liquid and gas flows although with the latter the validity may be restricted to gas flows in which the density changes in the measuring section are small as indicated for the particular type of flowmeter under discussion.

谁引用了ISO/TR 3313-1998 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号