飞机氧气系统中燃烧危险评估指南

Guide for Evaluating Combustion Hazards in Aircraft Oxygen Systems


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 SAE AIR 825/13-2003 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
SAE AIR 825/13-2003
发布日期
2003年01月01日
实施日期
废止日期
中国标准分类号
V44
国际标准分类号
49.095
发布单位
US-SAE
引用标准
ASTM D 2863-2000 ASTM G 63-1999 ASTM G 88-1990 ASTM G 93-1996 ASTM G 93-2003 ASTM G 94-1992 ASTM G 128-1995 ASTM G 128-2002 SAE AIR 1169 SAE AIR 4071-1997 SAE ARP 1176-1999
适用范围
This guide is intended to promote safe designs, operations and maintenance on aircraft and ground support oxygen systems. This is also a summary of some work by the ASTM G 4 Committee related to oxygen fire investigations and design concerns to reduce the risk of an oxygen fire. There have been many recent technological advances and additional test data is available for evaluating and controlling combustion hazards in oxygen equipment. Standards that use this new information are rapidly evolving. A guide is needed to assist organizations and persons not completely familiar with this process to provide oxygen systems with minimum risks of combustion. This guide does not necessarily address all the detailed issues and provide all data that will be needed. For a complete analysis, supplemental publications need to be consulted. This guide does discuss the basics of oxygen systems fire hazards. The hazard analysis process is discussed and a simple example to explain this process. Also, this guide does not address the overall system safety issues normally evaluated in aircraft programs. This guide does provide some important background and observations about combustion in oxygen systems. Information is given describing how to accomplish a hazard analysis. Furthermore, background is provided to explain critical locations in oxygen systems that need to be evaluated and other locations that do not require hazard analysis. It is important to note that any effort that requires a comprehensive and effective hazard analysis should use the complete information in the documents referenced herein. In general, the need for a hazard analysis applies primarily to gaseous oxygen equipment at 50 psi and higher pressures. LOX equipment does have hazards concerns as well and is usually treated similarly to GOX equipment at 500 psi. It should be noted that there are other phenomena associated with LOX equipment that must be considered. An example is that LOX can combine with hydrocarbons to form a gel, which explodes under impact. On the other hand, since LOX is a very cold liquid it tends to quench most possible ignition sources that could cause promoted ignition. When examining oxygen equipment at lower pressures the primary concern is the increased ignition and fire concern with combustible non-metals.

SAE AIR 825/13-2003系列标准


谁引用了SAE AIR 825/13-2003 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号