Railway applications —
Railway rolling stock
power and control
cables having special
fire performance —
Part 3-1: Cables with crosslinked
elastomeric insulation with reduced
dimensions — Single core cables
EN 50264-3-1 specifies requirements for, and constructions and dimensions of, single core cables of the
following types and voltage ratings:
? 0,6/1 kV unscreened, unsheathed (1 mm2 to 400 mm2);
? 1,8/3 kV unscreened, unsheathed (1,5 mm2 to 400 mm2);
? 1,8/3 kV unscreened, sheathed (1,5 mm2 to 400 mm2);
? 3,6/6 kV unscreened, sheathed (2,5 mm2 to 400 mm2).
All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free
sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is
encountered. The requirements provide for a continuous conductor temperature not exceeding 90° C and a
maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s.
Under fire conditions the cables exhibit special performance characteristics in respect of maximum
permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases.
EN 50264-3-1 should be read in conjunction with Part 1 “General requirements”.