This European Standard specifies the definitions and requirements for buried manholes and inspection chambers installed to a maximum depth of 6 m from ground level to the invert of the main chamber and manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE). These products are intended for use in pedestrian or vehicular traffic areas and underground installations conforming to the general requirements given in EN 476 and are used outside the building structure (application area code "U"). They are therefore marked accordingly with a "U". Such products are also deemed to meet the requirements of EN 13598-1 for application area U without the need for further testing. If additionally marked application area D then these products must additionally be tested to show compliance to the elevated temperature cycling requirement of Clause 10 of EN 13598-1. This European Standard is only applicable to those chamber / manhole items where the manufacturer has clearly stated in the documentation how the components shall be assembled to create a complete manhole or inspection chamber. The inspection chambers covered by this European Standard comprise the following: -- inspection chambers providing access to the drainage or sewerage system by means of inspection and cleaning equipment. -- chambers, designated as manholes providing man access to the drainage or sewerage system. The inspection chamber / manhole can be manufactured by various methods e.g. injection moulding, rotational moulding, low-pressure moulding or fabricated from components made in accordance with other standards. The jointing of components can be achieved using: -- elastomeric ring seal joints; -- adhesive joints for PVC-U; -- welded joints for PVC-U, PP and PE; -- extrusion welding; -- mechanical jointing. NOTE Both manholes and inspection chambers can be site assembled from different components, but can also be manufactured as a single unit. In either case, the following functional parts can be recognized: a) base (always present) In case of a one-piece chamber or manhole, the base part ends at a distance of 300 mm measured from the top of the main channel; b) riser (depth dependent); c) telescopic part (design dependent); d) cone (dependent on the design of near surface components and their recommended installation); e) other near surface components.
DIN EN 13598-2-2009由德国标准化学会 DE-DIN 发布于 2009-04,于 2010-05 废止。
DIN EN 13598-2-2009 在中国标准分类中归属于: Q81 供水、排水器材设备,在国际标准分类中归属于: 93.030 外部污水排放系统。
非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 DIN EN 13598-2-2009 前三页,或者稍后再访问。
点击下载后,生成下载文件时间比较长,请耐心等待......
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号