BS EN 777-3:2009
非家用多燃烧器的燃气高架辐射管加热器系统.第3部分:系统F安全

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 3: System F — Safety


标准号
BS EN 777-3:2009
发布
2009年
发布单位
英国标准学会
当前最新
BS EN 777-3:2009
 
 
引用标准
EN 10226-1:2004 EN 10226-2:2005 EN 126:2004 EN 161:2007 EN 257 EN 298:2003 EN 437:2003 EN 60335-1:2002 EN 60335-2-102:2006 EN 60529:1992 EN 60584-1:1995 EN 60584-2:1993 EN 88-1:2007 EN ISO 228-1:2003 EN ISO 3166-1:2006 EN ISO 6976:2005 ISO ISO 7005-1:1992
被代替标准
BS EN 777-3:2000
适用范围
This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube heaters incorporated into a multi-burner system (called system F and referred to in the body of the text as the “system”) with each burner unit under the control of an automatic burner control system. This standard is applicable to Type B52x and Type B53x systems (see 4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This standard is not applicable to: a) systems designed for use in domestic dwellings; b) outdoor systems; c) systems of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference test gas); d) systems having a draught diverter incorporated between the exhaust fan and the flue duct; e) systems having fully pre-mixed gas and air burners in which: 1) either the gas and all the combustion air are brought together just before the level of the combustion zone; or 2) the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone; f) systems that are designed for continuous condensation within the flue system under normal operating conditions; g) systems having combustion products evacuation ducts that are non-metallic. This standard is applicable to systems which are intended to be type tested. It also includes requirements concerning the evaluation of conformity, including factory production control, but these requirements only apply to POCEDs and their associated terminals. NOTE Requirements for systems which are not intended to be type tested would need to be subject to further consideration.

BS EN 777-3:2009相似标准


推荐

原子吸收光谱法--AAS仪器篇

可以测定共振吸收线位于真空紫外区非金属元素I、P、S等。f. 石墨炉原子化法所用设备比较复杂,成本比较高。但石墨炉原子化器在工作中比火焰原子化系统安全。g. 石墨炉产生总能量比火焰小,因此基体干扰较严 重,测量精密度比火焰原子化法差。石墨炉基本结构包括:石墨(杯)、炉体(保护气系统)、电源等三部分组成。工作是经历干燥、灰化、原子化和净化等四个阶段,即完成一次分析过程。1. ...

锥形量热仪供应信息

这个仪器被称为锥形量热仪,名字来源于截短了锥形加热器形状,加热器用100 kW/m2 热流辐射测试样品。  ...

FTT单体燃烧测试仪(SBI)

同样地,购买本设备用户将获得 FTT 双锥量热仪重要部分,之后购买锥形量热仪时可以节省大量费用。【烟气测量系统】• 符合 DIN 50055 标准白光光源和滤镜• 硅光电二极探测器和透光率电压输出• SBI 支撑托架• 全套校准滤光片• 通过软件进行分析【燃烧器、燃烧机组和控制器】• 两个无充气砂箱燃烧器和一个点火系统。• 用于安全供气监测UV燃烧器火焰探测器单元。...

原子吸收分光光度计各个部分作用

可消除光源不稳定性造成误差。可见,原子吸收分光光度计一般由光源,原子化器,单色器,检测器等四部分组成。一、光源1.作用:提供待测元素特征谱线——共振线。获得较高灵敏度和准确度。光源应满足如下要求:①. 辐射共振线半宽度明显小于吸收线半宽度---—锐线光源(Δν≤2×10-3nm);   ②. 共振辐射强度足够大,以保证有足够信噪比;   ③. 稳定性好,背景小 。...


BS EN 777-3:2009 中可能用到的仪器设备


谁引用了BS EN 777-3:2009 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved