BS EN 60947-7-2:2009
低压开关设备和控制设备.第7-2部分:辅助设备.铜导线用保护导线接线端子排

Low-voltage switchgear and controlgear - Part 7-2:Ancillary equipment - Protective conductor terminal blocks for copper conductors


标准号
BS EN 60947-7-2:2009
发布
2009年
发布单位
英国标准学会
当前最新
BS EN 60947-7-2:2009
 
 
引用标准
IEC 60439-1 AMD 1-2004 IEC 60439-1-1999 IEC 60715 AMD 1-1995 IEC 60715-1981 IEC 60947-1-2007 IEC 60947-7-1
被代替标准
06/30157054 DC-2006 BS EN 60947-7-2:2002
适用范围
This part of IEC 60947 specifies requirements for protective conductor terminal blocks with PE function up to 120 mm (250 kcmil) and for protective conductor terminal blocks with PEN function equal to and above 10 mm (AWG 8) with screw-type or screwless-type clamping units, primarily intended for industrial applications. Protective conductor terminal blocks are used to form the electrical and mechanical connection between copper conductors and the fixing support. lt is applicable to protective conductor terminal blocks for the connection of round copper conductors with or without special preparation having a cross-section between 0,2 mm and 120 mm (AWG 24 and 250 kcmil), intended to be used in circuits of a rated voltage not exceeding 1 000 V a.c. up to 1 000 Hz or 1 500 V d.c., most commonly in conjunction with terminal blocks according to IEC 60947-7-1. This standard may be used as guide for − protective conductor terminal blocks requiring the fixing of special devices to the conductors, for example quick connect terminations or wrapped connections, etc.; – protective conductor terminal blocks providing direct contact to the conductors by means of edges or points penetrating the insulation, for example insulation displacement connections, etc. Where applicable in this standard, the term “clamping unit” has been used instead of the term “terminal”. This is taken into account in case of reference to IEC 60947-1.

BS EN 60947-7-2:2009相似标准


推荐

KSY—12—16(A)电炉温度控制

3) 三相电源输入线及控制器输出与电炉的连接应用导线截面积不小于6mm²的芯绝缘线。   4) 电源中性线N4mm²的芯绝缘线,行程开关连接线应用导线截面积不小于1.0mm²的芯绝缘线。   5) 设备应可靠地接地,防止设备漏电,确保使用安全。   6) 热电偶的接线:电炉在出厂时配有黑色温度补偿导线。...

何为电气原理图接线图?

3、接线图中的导线有单根导线导线组(或线扎)、电缆等之分,可用连续线中断线来表示。凡导线走向相同的可以合并,线束来表示,到达接线端子板或电器元件的连接点时再分别画出。在用线束表示导线组、电缆等时可用加粗的线条表示,在不引起误解的情况下也可采用部分加粗。另外,导线及套管、穿线管的型号、根数规格应标注清楚。   ...

电气原理图的绘制原则与识别方法(一)

2、各电器元器件的位置、文字符号必须电气原理图中的标注一致,同一个电器元件的各部件(如同一个接触器的触点、线圈等)必须画在一起,各电器元件的位置应与实际安装位置一致。  3、不在同一安装板或电气柜上的电器元件或信号的电气连接一般应通过端子连接,并按照电气原理图中的接线编号连接。  4、走向相同、功能相同的多根导线可用单线或线束表示。...

石油化工仪表接地设计规范

2  保护接地2.0.1  用电仪表、自控设备的金属外壳正常不带电的金属部分,由于绝缘破坏而有可能带危险电压时,均应作保护接地。    它们包括:仪表盘、仪表柜、仪表箱、PLC及DCS机柜、操作站及辅助设备、供电盘、供电箱、接线盒、电缆槽、电缆托盘、穿线管、铠装电缆的铠装护层等。2.0.2  24V或低于24V供电的现场仪表、变送器、就地开关等,若无特殊要求时,可不作保护接地。...