Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmission with frequencies up to 250 MHz
This part of IEC 60603 covers 8-way, unshielded, free and fixed connectors, references
dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-
7, and specifies electrical transmission requirements for frequencies up to 250 MHz. These
connectors are typically used as category 6 connectors in class E cabling systems specified in
ISO/IEC 11801.
These connectors are intermateable and interoperable with other IEC 60603-7 series
connectors as defined in Clause 2 of IEC 60603-7.
These connectors are backward compatible with other IEC 60603-7 series connectors.