IEC 62533-2010
辐射防护装置.放射性物质的光子探测用高敏感度手持装置

Radiation protection instrumentation - Highly sensitive hand-held instruments for photon detection of radioactive material


IEC 62533-2010 发布历史

This International Standard applies to hand-held instruments used for the detection and localization of radioactive photon emitting materials. These instruments are highly sensitive meaning that they are designed to detect slight variations in the range of usual photon background caused mainly by illicit trafficking or inadvertent movement of radioactive material. Compared to pocket devices (see IEC 62401), this highly sensitive instrument allows the scanning of larger volume items such as vehicles or containers. They may also be used in fixed or temporarily fixed unattended mode to monitor check points or critical areas. These instruments also provide an indication of the ambient dose equivalent rate from photon radiation. However, this standard does not apply to the performance of radiation protection instrumentation which is covered in IEC 60846-1 and IEC 61526. These instruments may provide additional functions as described below without including all features of specialized portable identification devices as defined by IEC 62327: ? rejecting natural background variation encountered when used in movement; ? sorting alarms of interest from naturally occurring radioactive material (NORM) or medical radionuclides originated alarms; ? provide source categorization data (including limited photon spectra) to a remote location. The object of this standard is to establish performance requirements including physical characteristics, general test conditions, radiation characteristics, electrical safety, and environmental conditions. This standard provides examples of acceptable test methods to determine if an instrument meets the requirements of this standard. The results of tests performed provide information to users on the capability of radiation detection instruments for reliably detecting photon sources. Obtaining operating performance that meets or exceeds the specifications as stated in this standard depends upon properly establishing appropriate operating parameters, maintaining calibration, implementing a suitable response testing and maintenance program, providing proper training for operating personnel and developing operating procedures that address the instrument limitations and capabilities.

IEC 62533-2010由国际电工委员会 IX-IEC 发布于 2010-06。

IEC 62533-2010 在中国标准分类中归属于: F84 辐射防护仪器,在国际标准分类中归属于: 13.280 辐射防护,17.240 辐射测量。

IEC 62533-2010的历代版本如下:

  • 2010年06月 IEC 62533-2010 辐射防护装置.放射性物质的光子探测用高敏感度手持装置

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC 62533-2010 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
IEC 62533-2010
发布日期
2010年06月
实施日期
废止日期
中国标准分类号
F84
国际标准分类号
13.280;17.240
发布单位
IX-IEC
适用范围
This International Standard applies to hand-held instruments used for the detection and localization of radioactive photon emitting materials. These instruments are highly sensitive meaning that they are designed to detect slight variations in the range of usual photon background caused mainly by illicit trafficking or inadvertent movement of radioactive material. Compared to pocket devices (see IEC 62401), this highly sensitive instrument allows the scanning of larger volume items such as vehicles or containers. They may also be used in fixed or temporarily fixed unattended mode to monitor check points or critical areas. These instruments also provide an indication of the ambient dose equivalent rate from photon radiation. However, this standard does not apply to the performance of radiation protection instrumentation which is covered in IEC 60846-1 and IEC 61526. These instruments may provide additional functions as described below without including all features of specialized portable identification devices as defined by IEC 62327: ? rejecting natural background variation encountered when used in movement; ? sorting alarms of interest from naturally occurring radioactive material (NORM) or medical radionuclides originated alarms; ? provide source categorization data (including limited photon spectra) to a remote location. The object of this standard is to establish performance requirements including physical characteristics, general test conditions, radiation characteristics, electrical safety, and environmental conditions. This standard provides examples of acceptable test methods to determine if an instrument meets the requirements of this standard. The results of tests performed provide information to users on the capability of radiation detection instruments for reliably detecting photon sources. Obtaining operating performance that meets or exceeds the specifications as stated in this standard depends upon properly establishing appropriate operating parameters, maintaining calibration, implementing a suitable response testing and maintenance program, providing proper training for operating personnel and developing operating procedures that address the instrument limitations and capabilities.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号