IEC 61558-2-23-2010
变压器、反应器、供电机组及其它们的组合的安全性.第2-23部分:建筑工地用变压器和供电机组的试验和详细要求

Safety of transformers, reactors, power supply units and combinations thereof - Part 2-23: Particular requirements and tests for transformers and power supply units for construction sites


IEC 61558-2-23-2010 发布历史

This part of IEC 61558 deals with the safety of transformers for construction sites and power supply units incorporating transformers for construction sites. Transformers incorporating electronic circuits are also covered by this standard. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers transformers for construction sites and power supply units incorporating transformers for construction sites. This part is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated transformers, being isolating or safety isolating drytype transformers for the use on construction sites. The windings may be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V a.c., and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. This standard used in combination with Part 2-16 for Switch mode power supply units (SMPS) is also applicable to power supplies with internal operating frequencies higher than 500 Hz. Where the two requirements are in conflict the most severe take precedence The rated output does not exceed: – 25 kVA for single-phase transformers; – 40 kVA for poly-phase transformers. This part is applicable to transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 2 Transformers intended to supply distribution networks are not included in the scope. Isolating transformers and power supply units incorporating isolating transformers for construction sites have a no-load output voltage and a rated output voltage exceeding 50 V a.c. and not exceeding 250 V a.c. Safety isolating transformers and power supply units incorporating safety isolating transformers for construction sites have a no-load output voltage and a rated output voltage not exceeding 50 V a.c. NOTE 3 This standard is applicable to transformers for the supply of electricity in locations as specified in IEC 60364-7-704. The latter also specifies the protection by using an earthed midpoint or starpoint of the output winding. Transformers and power supply units covered by this part are used in applications where it is required by the installation rules or by the appliance specification for protection purposes. When the transformers or power supply units are incorporated into low voltage switchgear and controlgear assemblies for construction sites as specified in IEC 60439-4, the additional requirements of IEC 60439-4 will apply to the assembly. NOTE 4 For transformers filled with liquid dielectric or pulverised material, such as sand, additional requirements are under consideration. NOTE 5 Attention is drawn to the following: – measures to protect the enclosure and the components inside the enclosure against external influences like fungus, vermin, termites, solar-radiation and icing should also be considered; – the different conditions for transportation, storage, and operation of the transformers and power supply units should also be considered; – additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers and power supply units intended for use in special environments such as tropical environment. NOTE 6 Future technological development of transformers may necessitate a need to increase the upper limit of the frequencies, until then this standard may be used as a guidance document.

IEC 61558-2-23-2010由国际电工委员会 IX-IEC 发布于 2010-08。

IEC 61558-2-23-2010 在中国标准分类中归属于: K41 变压器,在国际标准分类中归属于: 29.180 变压器、电抗器、电感器。

IEC 61558-2-23-2010的历代版本如下:

  • 2000年05月01日 IEC 61558-2-23-2000 Securite Des Transformateurs@ Blocs D?Alimentation Et Dispositifs Analogues - Partie 2-23: Regles Particulieres Pour Les Transformateurs Pour Chantiers (Edition 1.0)
  • 2010年08月01日 IEC 61558-2-23-2010 Sécurité des transformateurs@ bobines d’inductance@ blocs d'alimentation et des combinaisons de ces élements – Partie 2-23: Règles particulières et essais pour les transformateurs et les blocs d'alimentation pour chantiers (Edition 2.0)

IEC 61558-2-23-2010



标准号
IEC 61558-2-23-2010
发布日期
2010年08月
实施日期
废止日期
中国标准分类号
K41
国际标准分类号
29.180
发布单位
国际电工委员会
适用范围
This part of IEC 61558 deals with the safety of transformers for construction sites and power supply units incorporating transformers for construction sites. Transformers incorporating electronic circuits are also covered by this standard. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers transformers for construction sites and power supply units incorporating transformers for construction sites. This part is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated transformers, being isolating or safety isolating drytype transformers for the use on construction sites. The windings may be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V a.c., and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. This standard used in combination with Part 2-16 for Switch mode power supply units (SMPS) is also applicable to power supplies with internal operating frequencies higher than 500 Hz. Where the two requirements are in conflict the most severe take precedence The rated output does not exceed: – 25 kVA for single-phase transformers; – 40 kVA for poly-phase transformers. This part is applicable to transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 2 Transformers intended to supply distribution networks are not included in the scope. Isolating transformers and power supply units incorporating isolating transformers for construction sites have a no-load output voltage and a rated output voltage exceeding 50 V a.c. and not exceeding 250 V a.c. Safety isolating transformers and power supply units incorporating safety isolating transformers for construction sites have a no-load output voltage and a rated output voltage not exceeding 50 V a.c. NOTE 3 This standard is applicable to transformers for the supply of electricity in locations as specified in IEC 60364-7-704. The latter also specifies the protection by using an earthed midpoint or starpoint of the output winding. Transformers and power supply units covered by this part are used in applications where it is required by the installation rules or by the appliance specification for protection purposes. When the transformers or power supply units are incorporated into low voltage switchgear and controlgear assemblies for construction sites as specified in IEC 60439-4, the additional requirements of IEC 60439-4 will apply to the assembly. NOTE 4 For transformers filled with liquid dielectric or pulverised material, such as sand, additional requirements are under consideration. NOTE 5 Attention is drawn to the following: – measures to protect the enclosure and the components inside the enclosure against external influences like fungus, vermin, termites, solar-radiation and icing should also be considered; – the different conditions for transportation, storage, and operation of the transformers and power supply units should also be considered; – additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers and power supply units intended for use in special environments such as tropical environment. NOTE 6 Future technological development of transformers may necessitate a need to increase the upper limit of the frequencies, until then this standard may be used as a guidance document.

IEC 61558-2-23-2010系列标准

IEC 61558-1 (REDLINE + STANDARD)-2017 IEC 61558-1 AMD 1-2009 电力变压器、电源、电抗器及类似设备的安全性.第1部分:一般要求和试验.修改件1 IEC 61558-1 CORR 1-2008 Safety of power transformers@ power supplies@ reactors and similar products – Part 1: General requirements and tests (Edition 2.0) IEC 61558-1 CORR 2-2010 CORRIGENDUM 2 Sécurité des transformateurs@ alimentations@ bobines d'inductance et produits analogues – Partie 1: Exigences générales et essais (Edition 2.1) IEC 61558-1 Corrigendum 1-2008 电力变压器、电源、电抗器和类似产品的安全性.第1部分:一般要求和试验.勘误1 IEC 61558-1 Corrigendum 2-2010 电力变压器、电源装置、电抗器及类似设备的安全性.第1部分:一般要求和试验.技术勘误2 IEC 61558-1 Corrigendum 3-2011 电力变压器,电源,电抗器及类似设备的安全性.第1部分:试验和一般要求 IEC 61558-1 Edition 1.1-1998 电力变压器、供电设备及类似设备的安全.第1部分:一般要求和试验.第1次修订 IEC 61558-1 Edition 2.1-2009 电力变压器、电源、电抗器及类似设备的安全性.第1部分:一般要求和试验 IEC 61558-1 INT 1-2003 电力变压器、电源装置及类似设备的安全.第1部分:一般要求和试验.注释单1 IEC 61558-1-2017 RLV 变压器、电抗器、电源装置及其组合的安全第1部分:一般要求和试验 IEC 61558-1-2005/AMD1-2009 修改件1.电力变压器、电源、电抗器和类似产品的安全.第1部分:一般要求和试验 IEC 61558-2-1-2021 IEC 61558-2-10-2014 变压器, 电抗器, 电源组件及其组合的安全性. 第2-10部分: 高绝缘水平分离变压器和输出电压超过1000 V的分离变压器的详细要求和试验 IEC 61558-2-12-2011 电力变压器,电源装置及类似设备的安全性.第2-12部分:恒压用恒变压器和供电机组的试验和详细要求 IEC 61558-2-13-2022 RLV 变压器、电抗器、电源装置及其组合的安全.第2-13部分:通用自耦变压器和包含自耦变压器的电源装置的特殊要求和试验 IEC 61558-2-14-2022 RLV 变压器、电抗器、电源装置及其组合件的安全第2-14部分:通用可变变压器和包含可变变压器的电源装置的特殊要求和试验 IEC 61558-2-15-2022 RLV 变压器、电抗器、电源装置及其组合的安全第2-15部分:医疗场所供电用医疗IT系统隔离变压器的特殊要求和试验 IEC 61558-2-16 AMD 1-2013 电力变压器、反应器、供电机组及其组合的安全性.第2-16部分:开关电源装置用开关电源装置和变压器的详细要求和试验 IEC 61558-2-16 Edition 1.1-2013 电压小于1100 V用变压器、电抗器、电源装置及类似设备的安全性.第2-16部分:开关电源装置和开关电源装置用变压器的详细要求和试验 IEC 61558-2-16-2021 IEC 61558-2-16-2021 IEC 61558-2-16-2009/AMD1-2013 修改件1.电源电压高达1100 V的变压器、电抗器、电源装置和类似产品的安全.第2-16部分:开关式电源装置和开关式电源装置用变压器的特殊要求和试验 IEC 61558-2-17-1997 电力变压器、电源装置及类似设备的安全 第2-17部分:开关模式电源变压器的特殊要求 IEC 61558-2-19-2000 电力变压器、电源装置及类似设备的安全 第2-19部分:扰动衰减变压器的特殊要求 IEC 61558-2-2-2022 RLV 变压器、电抗器、电源装置及其组合的安全.第2-2部分:控制变压器和包含控制变压器的电源装置的特殊要求和试验 IEC 61558-2-20-2010 电力变压器、电源装置及类似设备的安全性.第2-20部分:小型电抗器试验详细要求 IEC 61558-2-26-2013 电力变压器、反应器、供电机组及其组合的安全性.第2-26部分:全部用于节约能源和其他用途的变压器和供电机组的详细要求和试验 IEC 61558-2-3-2010 变压器、反应器、供电机组和其组合产品安全性.第2-3部分:气体燃烧器和燃油器用点火变压器试验和详细要求 IEC 61558-2-4-2021 RLV 变压器、电抗器、电源装置及其组合的安全第2-4部分:一般应用的隔离变压器和包含隔离变压器的电源装置的特殊要求和试验 IEC 61558-2-5-2010 变压器、反应器、供电机组及其组合的安全性.第2-5部分:剃须刀变压器和其电源装置的试验和详细要求 IEC 61558-2-6-2021 RLV 变压器、电抗器、电源装置及其组合的安全第2-6部分:一般应用的安全隔离变压器和包含安全隔离变压器的电源装置的特殊要求和试验 IEC 61558-2-7-2007 电力变压器、电源、电抗器和类似产品的安全.第2-7部分:玩具用变压器和电源的特殊要求和试验 IEC 61558-2-8-2010 变压器、反应器、供电机组及其组合的安全性.第2-8部分:变压器和供电机组的详细要求和试验 IEC 61558-2-9-2010 电力变压器、反应器、供电机组及其组合的安全性.第2-9部分:Ⅲ类手用钨丝灯变压器和供电机组的详细要求和试验 IEC 61558-5-7-2007