VDI/VDE 2617 Blatt 7-2008
三坐标测量机的精度 参数及其校核 三坐标测量机测量不确定度的仿真估算

Accuracy of coordinate measuring machines - Parameters and their checking - Estimation of measurement uncertainty of coordinate measuring machines by means of simulation


VDI/VDE 2617 Blatt 7-2008




购买全文,请联系:


标准号
VDI/VDE 2617 Blatt 7-2008
发布
2008年
发布单位
德国机械工程师协会
 
 
引用标准
DIN EN ISO 10360-1:2003 DIN EN ISO 10360-2:2006 DIN EN ISO 10360-3:2000 DIN EN ISO 10360-4:2003 DIN EN ISO 10360-5:2001 DIN EN ISO 10360-6:2002 DIN EN ISO 10360-7:2008 DIN EN ISO 10360-8:2011 DIN EN ISO 10360-9:2010 DIN EN ISO 1101:2006 DIN EN ISO 14253-1
被代替标准
VDI/VDE 2617 Blatt 7-2006
适用范围
This guideline describes the basic conditions for the determination of the uncertainty of measurements taken on CMMs by means of simulation taking into account measuring instrument, measuring object, measurement task, measurement strategy and ambient conditions. The guideline aims at harmonising the basic procedure without narrowing down the options for technical realisation. Measures allowing to make the procedure more transparent to the user are recommended, and ways for the user to verify the procedure are described.

VDI/VDE 2617 Blatt 7-2008相似标准


推荐

坐标测量机大致分类

精度称为精密型或计量型,主要在计量室使用。  低、中、高精度坐标测量机大体上可这样划分:低精度测量机单轴最大测量不确定大体在1×10¯4L左右,而空间最大测量不确定为(2-3)×10¯4L,其中L为最大量程;中等精度坐标测量机,其单轴与空间最大测量不确定分别约为1×10¯5L和(2-3)×10¯5L;精密型则分别小于1×10¯6L和(2-3)×10¯6L。...

坐标测量机误差分析

坐标测量机误差源纷繁复杂,很难将它们一一检测分离出来并加以修正,一般只修正那些对坐标测量机精度影响比较大误差源和那些比较容易分离误差源。目前研究最多坐标测量机机构误差。生产实践中使用坐标测量机绝大多数是正交坐标坐标测量机,对于一般坐标测量机而言,机构误差主要是指直线运动部件误差,包括定位误差、直线运动误差、角运动误差、以及垂直误差。...

影响坐标测量机精度因素

4.测量机械部分变化  测量机工作状测量机在长时间使用后,尤其是在环境比较差,温度波动情况比较大情况下,机械部分会有所变化,如:垂直变差,横粱长度长测量机附助腿端测量精度差等问题。此时就要进行测量机大修和精度校验。5.被测量形状误差及基准  因为坐标测量机测量原理是先采点,然后软件对所采点进行拟和计算误差。所以测量机测量时对零件形状误差有一定要求。...