SAE ARP 900B-2011
低温过滤器评估方法

Methods for Evaluating Cryogenic Filters


SAE ARP 900B-2011 发布历史

The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 L/min) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system from those recommended in this document. The test methods presented herein do not encompass testing of cryogenic bypass relief valves, differential pressure indicators, gages, or components other than a basic filter housing and element.

SAE ARP 900B-2011由美国机动车工程师协会 US-SAE 发布于 2011-12-19。

SAE ARP 900B-2011 在中国标准分类中归属于: V38 液压、冷气系统及其附件,在国际标准分类中归属于: 49.080 航空航天用流体系统和零部件。

SAE ARP 900B-2011的历代版本如下:

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 SAE ARP 900B-2011 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
SAE ARP 900B-2011
发布日期
2011年12月19日
实施日期
废止日期
中国标准分类号
V38
国际标准分类号
49.080
发布单位
US-SAE
引用标准
MIL-STD-810-2008 SAE ARP 598 SAE ARP 901-1968
被代替标准
SAE ARP 900A-1992
适用范围
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 L/min) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system from those recommended in this document. The test methods presented herein do not encompass testing of cryogenic bypass relief valves, differential pressure indicators, gages, or components other than a basic filter housing and element.

SAE ARP 900B-2011 中可能用到的仪器设备





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号