BS 6230-2005
商业和工业环境取暖(二类和三类家用煤气)用燃气强制对流式空气加热器的安装规范

Specification for installation of gas-fired forced convection air heaters for commercial and industrial space heating (2nd and 3rd family gases)


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:BS 6230-2005 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS 6230-2005 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
BS 6230-2005
发布日期
2005年10月11日
实施日期
2005年10月11日
废止日期
2011-07-31
中国标准分类号
Q83
国际标准分类号
97.100.20
发布单位
GB-BSI
代替标准
BS 6230-2011
适用范围
This British Standard specifies the installation requirements for direct and indirect gas-fired forced convection air heaters for space heating that are designed for commercial or industrial applications and to which the Gas Appliances (Safety) Regulations 1995 [1] apply. This standard applies to the installation of appliances that are designed to utilize gases of Group H of the second family (e.g. natural gas), gases of group P of the third family (e.g. propane) as well as gases of group B of the third family (e.g. butane) when supplied under the conditions of the third family pressure couple (see BS EN 437:2003). NOTE 1 This standard does not specifically cover LPG/air for which additional requirements might be necessary. This standard applies to the installation of direct gas-fired air heaters within the scope of BS EN 525:1998 and to indirect gas-fired forced convection air heaters within the scope of BS EN 621:1998, BS EN 1020:1998 and, where appropriate, BS EN 1196:1998. These standards cover air heaters having a net heat input not exceeding 300 kW. This standard also applies to the installation of direct gas-fired air heaters within the scope of BS 5990:1990 and to indirect gas-fired forced convection air heaters within the scope of BS 5991:1989. These standards cover air heaters having a gross heat input greater than 330 kW but not exceeding 2 MW (1.8 MW net). NOTE 2 For the purposes of this standard, installation includes design, inspection and commissioning. It is recognized that each of the tasks can be performed at the same time by different persons. NOTE 3 The ratio of gross to net heat input is approximately 1.11:1 for Group H (natural gas), 1.09:1 for group P (propane) and 1.08:1 for group B (butane). NOTE 4 The ventilation rates in cm2/kW of heat input given in this standard are based on the net calorific value. This standard also applies to air heaters designed to supply make-up air, door curtain heaters and transportable air heaters. It also covers installation of heaters in areas where petroleum or other flammable heavier-than-air vapours can be present (see 5.1.2). It does not include the safety requirements for installation where flammable dusts, toxic gases or flammable lighter-than-air gases might be present in significant quantities. NOTE 5 In such cases it is essential that liaison takes place with the Health and Safety Executive. This standard does not apply to the installation of air heaters to which the Gas Appliances (Safety) Regulations 1995 [1] do not apply, or that are designed for use in domestic premises.

谁引用了BS 6230-2005 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号