This part of IEC 61967 specifies a method to measure the conducted electromagentic emission (EME) of integrated circuits by direct radion frequency (RF) current measurement with a 1 ohm resitive probe and RF voltage measurement using a 150 ohm coupling network. These methods quarantee a high degree of repeatability and correlation of EME measurements.