PD CEN/TR 10350-2013
钢铁材料化学分析.使用标准物质检查一种分析方法精确度的内部实验室程序

Analysis of steels and irons - Internal laboratory procedure for checking the accuracy of an analytical method by using Certified Reference Materials


PD CEN/TR 10350-2013 发布历史

The present statistical procedure describes how to check results for absence of bias by comparison of these analytical results with those obtained during the certification of CRMs. If the resulting data confirm the absence of bias, the method may be considered accurate when applied to all steels and irons whose composition ranges are adequately covered or bounded by the CRMs used. The resulting data give also an estimate of the repeatability and/or the intermediate precision ("intralaboratory reproducibility") for the CRMs used. The comparison of these analytical data with the repeatability data obtained during the certification may also be performed depending on the strict purpose of the method under consideration. For the purpose of this Technical Report, the use of existing CRMs is essential for the assessment of the trueness, but it may be only indicative for the other statistical data.

PD CEN/TR 10350-2013由欧洲标准化委员会 IX-CEN 发布于 2013-02-01,并于 2013-02-01 实施。

PD CEN/TR 10350-2013 在中国标准分类中归属于: H11 钢铁与铁合金分析方法,在国际标准分类中归属于: 77.040.30 金属材料化学分析。

PD CEN/TR 10350-2013的历代版本如下:

  • 2009年 PD CEN/TR 10350-2009 钢铁制品分析.使用认证参考资料检查分析方法的准确度的内部实验室程序
  • 2013年02月01日 PD CEN/TR 10350-2013 钢铁材料化学分析.使用标准物质检查一种分析方法精确度的内部实验室程序

PD CEN/TR 10350-2013



标准号
PD CEN/TR 10350-2013
发布日期
2013年02月01日
实施日期
2013年02月01日
废止日期
中国标准分类号
H11
国际标准分类号
77.040.30
发布单位
欧洲标准化委员会
适用范围
The present statistical procedure describes how to check results for absence of bias by comparison of these analytical results with those obtained during the certification of CRMs. If the resulting data confirm the absence of bias, the method may be considered accurate when applied to all steels and irons whose composition ranges are adequately covered or bounded by the CRMs used. The resulting data give also an estimate of the repeatability and/or the intermediate precision ("intralaboratory reproducibility") for the CRMs used. The comparison of these analytical data with the repeatability data obtained during the certification may also be performed depending on the strict purpose of the method under consideration. For the purpose of this Technical Report, the use of existing CRMs is essential for the assessment of the trueness, but it may be only indicative for the other statistical data.