ASTM E481-16由美国材料与试验协会 US-ASTM 发布于 2016。
ASTM E481-16在国际标准分类中归属于: 17.240 辐射测量。
3.1 This test method uses one monitor (cobalt) with a nearly 1/v absorption cross-section curve and a second monitor (silver) with a large resonance peak so that its resonance integral is large compared to the thermal cross section. The pertinent data for these two reactions are given in Table 1. The equations are based on the Westcott formalism ((2, 3) and Practice E261) and determine a Westcott 2200 m/s neutron fluence rate nv0 and the Westcott epithermal index parameter . References (4, 5, and 6) contain a general discussion of the two-reaction test method. In this test method, the absolute activities of both cobalt and silver monitors are determined. This differs from the test method in the references wherein only one absolute activity is determined.
(A) The numbers in parenthesis following given values are the uncertainty in the last digit(s) of the value; 0.729 (8) means 0.729 ± 0.008, 70.8(1) means 70.8 ± 0.1.(B) A 2200 m/s cross section (E = 0.0253 eV, T = 20°C) was taken from the sources indicated in Ref (9).(C) Cross section uncertainty data is taken from Ref (7) , the cross section comes from the other reference.(D) Calculated using Eq 10.(E) Cross section uncertainty comes from covariance data provided in the cross section source. The other reference indicates the source of the cross section.(F) In Fig. 1, Θ = 4ErkT/AΓ 2 = 0.2 corresponds to the value for 109Ag for T = 293 K, ∑r = N0σr, max. σr, max=29999 barn at 5.19 eV (