IEC 60331-1-2018
电缆在着火条件下的试验.电路完整性.第1部分:额定电压高达(和包括)0.6/1.0 KV,全径大于20 mm的电缆在温度不低于830°C的冲击火焰下的试验方法

Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm


IEC 60331-1-2018 发布历史

This part of IEC 60331 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. This document is applicable to cables of rated voltage not exceeding 600 V/1000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables. It is intended for use when testing cables of greater than 20 mm overall diameter. Cables of smaller diameter are intended to be tested using the apparatus, procedure and requirements of IEC 60331-2. This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1. Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used. Annex A provides the method of verification of the burner and control system used for the test. Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this document. CAUTION - The test given in this standard may involve the use of dangerous voltages and temperatures. Suitable precautions should be taken against the risk of shock, burning, fire and explosion that may be involved, and against any noxious fumes that may be produced.

IEC 60331-1-2018由国际电工委员会 IX-IEC 发布于 2018-0301。

IEC 60331-1-2018 在中国标准分类中归属于: K13 电缆及其附件,在国际标准分类中归属于: 13.220.40 材料和制品的可燃性和燃烧性能,29.020 电气工程综合,29.060.20 电缆。

IEC 60331-1-2018 发布之时,引用了标准

  • IEC 60269-3-2010 低压熔断器.第3部分:非熟练人员使用的熔断器(主要是家用和类似用途的熔断器)的补充要求.A型至F型熔断器的标准系统样例*2010-05-01 更新
  • IEC 60584-1-2013 热电偶.第1部分:3.0版本:电动势(EMF)规格和公差*2013-08-01 更新

* 在 IEC 60331-1-2018 发布之后有更新,请注意新发布标准的变化。

IEC 60331-1-2018的历代版本如下:

  • 2009年05月 IEC 60331-1-2009 电缆在着火条件下的试验.电路完整性.第1部分:额定电压高达(和包括)0.6/1.0 KV,全径大于20 mm的电缆在温度不低于830°C的冲击火焰下的试验方法
  • 1970年01月 IEC 60331-1-2018 电缆在着火条件下的试验.电路完整性.第1部分:额定电压高达(和包括)0.6/1.0 KV,全径大于20 mm的电缆在温度不低于830°C的冲击火焰下的试验方法

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC 60331-1-2018 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
IEC 60331-1-2018
发布日期
1970年01月
实施日期
废止日期
中国标准分类号
K13
国际标准分类号
13.220.40;29.020;29.060.20
发布单位
IX-IEC
引用标准
IEC 60269-3-2010 IEC 60584-1-2013
被代替标准
IEC 20/1781A/FDIS-2018 IEC 60331-1-2009
适用范围
This part of IEC 60331 specifies the test method for cables which are required to maintain circuit integrity when subject to fire and mechanical shock under specified conditions. This document is applicable to cables of rated voltage not exceeding 600 V/1000 V, including those of rated voltage below 80 V, metallic data and telecom cables and optical fibre cables. It is intended for use when testing cables of greater than 20 mm overall diameter. Cables of smaller diameter are intended to be tested using the apparatus, procedure and requirements of IEC 60331-2. This document includes details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to electric power and control cables with rated voltage up to and including 600 V/1000 V. Details for the specific point of failure, continuity checking arrangement, test sample, test procedure and test report relevant to metallic data and telecom cables and optical fibre cables are not given by IEC 60331-1. Although the scope is restricted to cables with rated voltage up to and including 0,6/1,0 kV, the procedure can be used, with the agreement of the manufacturer and the purchaser, for cables with rated voltage up to and including 1,8/3 (3,3) kV, provided that suitable fuses are used. Annex A provides the method of verification of the burner and control system used for the test. Requirements are stated for an identification that may optionally be marked on the cable to signify compliance with this document. CAUTION - The test given in this standard may involve the use of dangerous voltages and temperatures. Suitable precautions should be taken against the risk of shock, burning, fire and explosion that may be involved, and against any noxious fumes that may be produced.

IEC 60331-1-2018系列标准

IEC 60331-11 AMD 1-2009 电缆在着火条件下的试验.电路完整性.第11部分:仪器.火焰温度等于高于750°C时的孤立火焰.修改件1 IEC 60331-11 Edition 1.1-2009 电缆在着火条件下的试验.电路完整性.第11部分:仪器.火焰温度等于高于750 °C时的孤立火焰 IEC 60331-11-1999/AMD1-2009 修改件1.着火条件下电缆的试验.电路完整性.第11部分:仪器.在至少750°C的火焰温度下单独着火 IEC 60331-11-1999/AMD1-2009 修改件1.着火条件下电缆的试验.电路完整性.第11部分:仪器.在至少750°C的火焰温度下单独着火 IEC 60331-12-2002 着火条件下电缆的试验.电路完整性.第12部分:仪器.至少在830鳦条件下冲击燃烧 IEC 60331-3:2018 RLV 着火条件下电缆的试验.电路完整性.第3部分:在金属外壳中试验的额定电压0.6/1.0 kV及以下电缆在至少830°C温度下冲击着火的试验方法 IEC 60331-2-2018 着火条件下电缆的试验.电路完整性.第2部分:额定电压高达和包括0.6/1.0 KV,全径不超过20 mm的电缆在温度不低于830°C的冲击火焰下的试验方法 IEC 60331-21-1999 着火条件下电缆的试验 电路完整性 第21部分:程序和要求 额定电压0.6/1.0kV及以下的电缆 IEC 60331-23-1999 着火条件下电缆的试验 电路完整性 第23部分:程序和要求 电数据电缆 IEC 60331-25-1999 着火条件下电缆的试验 电路完整性 第25部分:程序和要求 光缆 IEC 60331-3-2018 着火条件下电缆的试验.电路完整性.第3部分:电缆在至少830℃温度下冲击着火的试验方法 额定电压小于等于0.6/1.0 kV 在金属外壳中进行试验 IEC 60331-31-2002 着火条件下电缆的试验.电路完整性.第31部分:冲击着火的程序和要求.额定电压高达(和包括)0,6/1,0 KV的电缆