IEC 61466-2 Edition 1.2-2018
额定电压超过1000V的架空线用复合绝缘子串组合件.第2部分:尺寸和电特性

Composite string insulator units for overhead lines with a nominal voltage greater than 1000 V - Part 2: Dimensional and electrical characteristics


IEC 61466-2 Edition 1.2-2018 发布历史

This part of IEC 61466 is applicable to composite string insulators units with a specified mechanical load (SML) of 40 kN and 70 kN to 600 kN for AC overhead distribution lines with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz. It also applies to insulators of similar design used in substations or on electric traction lines for railway applications. This standard applies to string insulator units of composite type with couplings fittings in accordance with IEC 61466-1. This standard prescribes specified specifies values for electrical and dimensional characteristics of for composite string insulators units for overhead distribution lines with a highest minimum lightning impulse withstand voltage (BIL) level of 325 kV up to 3100 kV and a specified mechanical load (SML) of 40 kN and 70 kN to 600 kN. NOTE General definitions and methods of testing are given in IEC 61109.

IEC 61466-2 Edition 1.2-2018由国际电工委员会 IX-IEC 发布于 2018-0501。

IEC 61466-2 Edition 1.2-2018 在中国标准分类中归属于: K48 绝缘子,在国际标准分类中归属于: 29.080.10 绝缘子。

IEC 61466-2 Edition 1.2-2018 发布之时,引用了标准

  • IEC 60071-1-1993 绝缘配合 第1部分:定义、原则和规则*1993-12-01 更新
  • IEC 60071-2-1976 绝缘配合.第2部分:应用导则*1976-07-30 更新
  • IEC/TS 60815-3-2008 污染条件下用高压绝缘子的选择和定尺寸.第3部分:交流系统用聚合体绝缘子*2008-10-01 更新
  • IEC 61109-1992 标称电压大于1000V的交流架空线路用复合绝缘子 定义、试验方法和验收准则*1992-03-01 更新
  • IEC 61466-1-1997 标称电压1000V以上的架空线路用复合绝缘子串单元 第1部分:标准强度等级和端配件*1997-02-01 更新

* 在 IEC 61466-2 Edition 1.2-2018 发布之后有更新,请注意新发布标准的变化。

IEC 61466-2 Edition 1.2-2018的历代版本如下:

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC 61466-2 Edition 1.2-2018 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
IEC 61466-2 Edition 1.2-2018
发布日期
1970年01月
实施日期
废止日期
中国标准分类号
K48
国际标准分类号
29.080.10;29.240.20
发布单位
IX-IEC
引用标准
IEC 60071-1-1993 IEC 60071-2-1976 IEC/TS 60815-3-2008 IEC 61109-1992 IEC 61466-1-1997
适用范围
This part of IEC 61466 is applicable to composite string insulators units with a specified mechanical load (SML) of 40 kN and 70 kN to 600 kN for AC overhead distribution lines with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz. It also applies to insulators of similar design used in substations or on electric traction lines for railway applications. This standard applies to string insulator units of composite type with couplings fittings in accordance with IEC 61466-1. This standard prescribes specified specifies values for electrical and dimensional characteristics of for composite string insulators units for overhead distribution lines with a highest minimum lightning impulse withstand voltage (BIL) level of 325 kV up to 3100 kV and a specified mechanical load (SML) of 40 kN and 70 kN to 600 kN. NOTE General definitions and methods of testing are given in IEC 61109.