13.230 防爆 标准查询与下载



共找到 375 条与 防爆 相关的标准,共 25

Explosives atmospheres - Explosion prevention and protection - Part 1 : basic concepts and methodology.

ICS
13.230
CCS
C67
发布
2011-10-01
实施
2011-10-14

This European Standard specifies methods for the identification and assessment of hazardous situations leading to explosion and the design and construction measures apporpriate for the required safety.This is achieved by:--risk assessment;--risk reduction.

Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology; German version EN 1127-1:2011

ICS
13.230
CCS
C67
发布
2011-10
实施
2011-10-01

This European Standard specifies requirements for the design and construction of non-electrical equipment,intended for use in potentially explosive atmospheres, protected by the type of protection Constructional Safety C.

Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'; German version EN 13463-5:2011

ICS
13.230
CCS
K35
发布
2011-10
实施
2011-10-01

Determination of maximum explosion pressure and the maximum rate of pressure rise of gases and vapours; German version EN 15967:2011

ICS
13.230
CCS
C67
发布
2011-10
实施
2011-10-01

This European Standard specifies the requirements for flameless explosion venting devices used to protest enclosures against the major effects of internal explosions arising from the rapid burning of suspended dust.

Flameless explosion venting devices; German version EN 16009:2011

ICS
13.230
CCS
C67
发布
2011-10
实施

An explosion diverter is used to divert explosions propagating through ducts,thus preventing flame jet ignition and pressure piling in connected protected enclosures.

Explosion diverters; German version EN 16020:2011

ICS
13.230
CCS
C67
发布
2011-10
实施

An explosion diverter is used to divert explosions propagating through ducts, thus preventing flame jet ignition and pressure piling in connected protected enclosures. It will reduce the risk of flame transmission.This European Standard describes the basic design of a pipe-in-pipe diverter and specifies the testing requirements and the application of explosion diverters. This European Standard covers:- a test method for assessing the efficacy of explosion diverters;- design rules for a type of pipe-in-pipe diverter;- demands to venting device on diverter;- installation requirements;- maintenance requirements;- marking.This European Standard considers dust/a

Explosion diverters

ICS
13.230
CCS
发布
2011-09-30
实施
2011-09-30

The European Standard test method is designed to produce measurements of explosion pressure and the maximum explosion pressure, the rate of explosion pressure rise and the maximum rate of explosion pressure rise of a quiescent flammable gas/air/inert mixture in closed volume at ambient temperature and pressure. In this European Standard, the term """"gas"""" includes vapours but not mists. Detonation and decomposition phenomena are not considered in this European Standard.The pressures and rates of pressure rise measured by the procedures specified in this European Standard are not applicable to flameproof enclosures, that is enclosures intended to withstan

Determination of maximum explosion pressure and the maximum rate of pressure rise of gases and vapours

ICS
13.230
CCS
发布
2011-09-30
实施
2011-09-30

Determination of maximum explosion pressure and the maximum rate of pressure rise of gases and vapours.

ICS
13.230
CCS
C67
发布
2011-09-01
实施
2011-09-30

This European Standard specifies methods for the identification and assessment of hazardous situations leading to explosion and the design and construction measures appropriate for the required safety. This is achieved by:  risk assessment;  risk reduction. The safety of equipment, protective systems and components can be achieved by eliminating hazards and/or limiting the risk, i.e. by: a) appropriate design (without using safeguarding); b) safeguarding; c) information for use; d) any other preventive measures. Measures in accordance with a) (prevention) and b) (protection) against explosions are dealt with in Clause 6, measures according to c) against explosions are dealt with in Clause 7. Measures in accordance with d) are not specified in this European Standard. They are dealt with in EN ISO 12100:2010, Clause 6. The preventive and protective measures described in this European Standard will not provide the required level of safety unless the equipment, protective systems and components are operated within their intended use and are installed and maintained according to the relevant codes of practice or requirements. This standard specifies general design and construction methods to help designers and manufacturers in achieving explosion safety in the design of equipment, protective systems and components. This European Standard is applicable to any equipment, protective systems and components intended to be used in potentially explosive atmospheres, under atmospheric conditions. These atmospheres can arise from flammable materials processed, used or released by the equipment, protective systems and components or from materials in the vicinity of the equipment, protective systems and components and/or from the materials of construction of the equipment, protective systems and components. This European Standard is applicable to equipment, protective systems and components at all stages of its use. This European Standard is only applicable to equipment group II which is intended for use in other places than underground parts of mines and those parts of surface installations of such mines endangered by firedamp and/or flammable dust. This European Standard is not applicable to: 1) medical devices intended for use in a medical environment; 2) equipment, protective systems and components where the explosion hazard results exclusively from the presence of explosive substances or unstable chemical substances; 3) equipment, protective systems and components where the explosion can occur by reaction of substances with other oxidizers than atmospheric oxygen or by other hazardous reactions or by other than atmospheric conditions; 4) equipment intended for use in domestic and non-commercial environments where potentially explosive atmospheres may only rarely be created, solely as a result of the accidental leakage of fuel gas; 5) personal protective equipment covered by Directive 89/686/EEC; 6) seagoing vessels and mobile offshore units together with equipment on board such vessels or units; 7) means of transport, i.e. vehicles and their trailers intended solely for transporting passengers by air or by road, rail or water networks, as well as means of transport insofar as such means are designed for transporting goods by air, by public road or rail networks or by water; vehicles intended for use in a potentially explosive atmosphere shall not be excluded; 8) the design and construction of systems containing desired, controlled combustion processes, unless they can act as ignition sources in potentially explosive atmospheres.

Explosive atmospheres. Explosion prevention and protection. Basic concepts and methodology

ICS
13.230
CCS
C67
发布
2011-08-31
实施
2011-08-31

An explosion diverter is used to divert explosions propagating through ducts, thus preventing flame jet ignition and pressure piling in connected protected enclosures. It will reduce the risk of flame transmission. This European Standard describes the basic design of a pipe-in-pipe diverter and specifies the testing requirements and the application of explosion diverters. This European Standard covers:  a test method for assessing the efficacy of explosion diverters;  design rules for a type of pipe-in-pipe diverter;  demands to venting device on diverter;  installation requirements;  maintenance requirements;  marking. This European Standard considers dust/air explosive atmospheres only.

Explosion diverters

ICS
13.230
CCS
C67
发布
2011-08-31
实施
2011-08-31

Technical specification for electrical explosion-proof safety testing in hazardous locations

ICS
13.230
CCS
C67
发布
2011-08-11
实施
2011-08-11

1.1 This European Standard specifies the requirements for the design and construction of non-electrical equipment, intended for use in potentially explosive atmospheres, protected by the type of protection Constructional Safety """"c"""".1.2 This European Standard supplements the requirements in EN 13463-1, the contents of which also apply in full to equipment constructed in accordance with this European Standard.1.3 The type of ignition protection described in the standard can be used either on its own or in combination with other types of ignition protection to meet the requirements for equipment of Group I, category M2 or Group II, categories 1 and 2 dep

Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'

ICS
13.230
CCS
发布
2011-08-05
实施
2011-08-05

This European Standard specifies the requirements for flameless explosion venting devices used to protect enclosures against the major effects of internal explosions arising from the rapid burning of suspended dust, vapour or gas contained within. It includes the requirements for the design, inspection, testing, marking, documentation, and packaging. This standard is applicable to flameless explosion venting devices which are put on the market as autonomous protective systems.Explosion venting devices are protective systems comprised of a pressure sensitive membrane fixed to and forming part of the structure that it protects. They are designed to intervene

Flameless explosion venting devices

ICS
13.230
CCS
发布
2011-08-05
实施
2011-08-05

This European Standard specifies the requirements for flameless explosion venting devices used to protect enclosures against the major effects of internal explosions arising from the rapid burning of suspended dust, vapour or gas contained within. It includes the requirements for the design, inspection, testing, marking, documentation, and packaging. This standard is applicable to flameless explosion venting devices which are put on the market as autonomous protective systems. Explosion venting devices are protective systems comprised of a pressure sensitive membrane fixed to, and forming part of, the structure that it protects. They are designed to intervene in the event of an explosion at a predetermined pressure, to immediately open a vent area sufficient to ensure that the maximum pressure attained by an explosion within the enclosure does not exceed the maximum pressure the structure is designed to withstand. Flameless explosion venting devices typically consist of an explosion venting device in combination with a flame quenching element to avoid the transmission of flames into the surroundings. They are used to allow explosion venting in situations where otherwise the hazards of flames and pressure resulting from the venting would harm personnel or damage structures. The application and specification of explosion venting devices is outlined for dust explosion protection in EN 14491 and for gas explosion protection in EN 14994. This European Standard covers the flameless explosion venting of dust, vapour and gas explosions. This European Standard does not cover details for the avoidance of ignition sources from detection devices or other parts of the flameless explosion venting devices.

Flameless explosion venting devices

ICS
13.230
CCS
C67
发布
2011-07-31
实施
2011-07-31

本标准规定了爆炸性环境用防爆电梯防爆性能检验的方法。 本标准适用于防爆客梯、防爆货梯、防爆液压客梯和防爆液压货梯。 本标准不适用于煤矿和炸药制造、加工场所。

Inspection regulations for explosion-proof safety performance of explosion-proof elevators

ICS
13.230
CCS
C67
发布
2011-07-14
实施
2011-10-01

本标准规定了爆炸性环境用防爆起重机械防爆性能检验的方法。 本标准适用于防爆起重机械包括防爆桥式起重机、防爆梁式起重机和防爆钢丝绳电动葫芦。 本标准不适用于煤矿和炸药制造、加工场所。

Inspection regulations for explosion-proof safety performance of explosion-proof lifting machinery

ICS
13.230
CCS
C67
发布
2011-07-14
实施
2011-10-01

This European Standard specifies the requirements for the design and construction of non-electrical equipment, intended for use in potentially explosive atmospheres, protected by the type of protection Constructional Safety 'c'.This European Standard supplements the requirements in EN 13463-1, the contents of which also apply in full to equipment constructed in accordance withThis European Standard. The type of ignition protection described in the standard can be used either on its own or in combination with other types of ignition protection to meet the requirements for equipment of Group I, category M2 or Group II, categories 1 and 2 depending on the ignition hazard assessment in EN 13463-1. Type of ignition protection 'c' is not applicable for Group I for M1. These requirements are specified in EN 50303. NOTE Most category 3 equipment, only needs to meet the requirements of EN 13463-1, but some category 3 equipment may have to meet the requirements of this European Standard for some of the ignition sources identified in the ignition hazard assessment.

Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'

ICS
13.230
CCS
发布
2011-07-01
实施

This European Standard specifies methods for the identification and assessment of hazardous situations leading to explosion and the design and construction measures appropriate for the required safety.

Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology

ICS
13.230
CCS
发布
2011-07-01
实施

An explosion diverter is used to divert explosions propagating through ducts, thus preventing flame jet ignition and pressure piling in connected protected enclosures. It will reduce the risk of flame transmission.This European Standard describes the basic design of a pipe-in-pipe diverter and specifies the testing requirements and the application of explosion diverters.This European Standard covers: a test method for assessing the efficacy of explosion diverters; design rules for a type of pipe-in-pipe diverter; demands to venting device on diverter; installation requirements; maintenance requirements; marking.This European Standard considers dust/air explosive atmospheres only.

Explosion diverters

ICS
13.230
CCS
发布
2011-07-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号