17.120.20 明渠中流量的测量 标准查询与下载



共找到 565 条与 明渠中流量的测量 相关的标准,共 38

This International Standard specifies methods of determining the position of hydrometric boats with respect to known points on the banks of rivers or estuaries. It applies to conventional surveying techniques and, in recognition of the availability of more sophisticated equipment, describes the principles of operation of currently available electronic positioning equipment. This International Standard does not cover the requirements for position fixing that occur in large scale hydrographic surveys such as those conducted on oceans.

Liquid flow measurement in open channels -- Position fixing equipment for hydrometric boats

ICS
17.120.20
CCS
发布
2015-09-03
实施

This International Standard specifies the functional requirements of instrumentation for measuring the level of water surface (stage), primarily for the purpose of determining flow rates. This International Standard is supplemented by an annex providing guidance on the types of water level measurement devices currently available and the measurement uncertainty associated with them (see Annex A).

Hydrometry -- Water level measuring devices

ICS
17.120.20
CCS
发布
2015-09-03
实施

This International Standard deals with the method and techniques for the sampling of suspended sediment and estimation of sediment transport rates in natural and man-made channels influenced by tidal action.

Hydrometric determinations -- Measurement of suspended sediment transport in tidal channels

ICS
17.120.20
CCS
发布
2015-09-03
实施

This International Standard specifies methods for determining stage-fall-discharge relationships for a stream reach where variable backwater occurs either intermittently or continuously. Two gauging stations, a base reference gauge and an auxiliary gauge are required for gauge height measurements. A number of discharge measurements are required in order to calibrate the rating to the accuracy required by this International Standard. The preparation of rating curves is not described in detail in this International Standard. NOTE For a more detailed description of preparing rating curves, see the methods described in ISO 1100-2

Measurement of liquid flow in open channels -- Stage-fall-discharge relationships

ICS
17.120.20
CCS
发布
2015-09-03
实施

This International Standard gives guidelines for selection of a particular type of flow-gauging structure for measurement of liquid flow in open channels. It sets out the factors, and summarizes the parameters which may influence such a selection. NOTE In general, a flow-gauging structure is used when high accuracy is required for continuous records of flow.

Hydrometric determinations -- Flow measurements in open channels using structures -- Guidelines for selection of structure

ICS
17.120.20
CCS
发布
2015-09-03
实施

Estimation of sediment deposition in reservoirs using one dimensional simulation models

ICS
17.120.20
CCS
发布
2015-08-15
实施

Hydrometry. Methods of measurement of bedload discharge

ICS
17.120.20
CCS
P12
发布
2015-06-30
实施
2015-06-30

Hydrometry - Methods of measurement of bedload discharge

ICS
17.120.20
CCS
发布
2015-06-01
实施

Hydrometry - Cableway systems for stream gauging (ISO 4375:2014); German version EN ISO 4375:2014

ICS
17.120.20
CCS
N12
发布
2015-03
实施

La présente Norme internationale définit les exigences applicables aux équipements, points d'ancrage, supports et accessoires destinés à des systèmes de suspension par câbles aériens pour le jaugeage en rivière. La présente Norme internationale couvre aussi bien les systèmes entièrement mis en oeuvre depuis la berge d'un fleuve que les systèmes mis en oeuvre à partir d'un chariot suspendu pour le personnel (également appelé "télécabine"). La présente Norme internationale couvre uniquement les systèmes de téléphérique utilisés pour réaliser des mesurages hydrométriques. Si l'installation du téléphérique est nécessaire pour être certifiée comme équipement de

Hydrometry - Cableway systems for stream gauging

ICS
17.120.20
CCS
N12
发布
2015-01-10
实施
2015-01-10

Liquid flow measurement in open channels-Rotating element current-meters

ICS
17.120.20
CCS
A42;N12
发布
2014/12/3
实施
2014/12/3

Liquid flow measurement in open channels-Calibration of rotating-element current-meters in straight open tanks

ICS
17.120.20
CCS
A53;N12
发布
2014/12/3
实施
2014/12/3

Liquid flow measurement in open channels-Direct depth sounding and suspension equipment

ICS
17.120.20
CCS
N12
发布
2014/12/3
实施
2014/12/3

This part of ISO 9555 deals with the use of fluorescent tracers in discharge measurements by the dilution method. Apparatus and methods of general application are set out in ISO 9555-1 and are not repeated here, with the exception of those relating specifically to fluorescent tracers. The use of fluorescent tracers is attractive because of the small amounts of tracer needed to make a discharge measurement. Certain fluorescent tracers can be measured at concentrations of less than 1 μg/l. Fluorescent tracers are easy to handle and their concentrations can be readily determined.

Measurement of liquid flow in open channels -- Tracer dilution methods for the measurement of steady flow -- Part 4: Fluorescent tracers

ICS
17.120.20
CCS
发布
2014-12-25
实施

This part of ISO 9555 concerns principles of the constant rate injection method and the sudden injection method (integration method), and the principles of injection, sampling and analysis which apply for all types of tracer. It is important to note that the tracers used and their concentrations should be compatible with the legislation of each country regarding the occasional and short-duration discharges of foreign substances into natural waters. They should also take into account possible short-term or long-term influences on flora and fauna, both natural and domestic. In the absence of appropriate regulations, the World Health Organization's (WHO) Guidelines for drinking water quality should serve as a guide, taking account of the brief nature of the measurement and of the use that is to be made of water receiving the injected tracer.

Measurement of liquid flow in open channels -- Tracer dilution methods for the measurement of steady flow -- Part 1: General

ICS
17.120.20
CCS
发布
2014-12-25
实施

This part of ISO 9555 deals with the use of chemical tracers in discharge measurements by the dilution method. Apparatus and methods of general application are set out in ISO 9555-1 and are not repeated here, with the exception of those relating specifically to chemical tracers. Chemical tracers have several advantages as follows. a) As with fluorescent tracers, the handling of the tracer follows normal chemical laboratory practice, and no special equipment (e.g. radiation shielding) is required. Care is still required, however, when handling concentrated tracer, to avoid contamination of samples and, with some tracers, for reasons of chemical toxicity. b) In general, chemical tracers are widely available commercially, and may be stored indefinitely. c) Analysis may be possible using laboratory facilities currently used for water quality determination. d) In general, chemical tracers are photochemically stable. The disadvantages of chemical tracers are as follows: a) Their detection limits are relatively high and therefore a larger quantity of tracer is required for each gauging than in the case of radioactive or fluorescent tracers. For practical reasons this may restrict their application to small discharges. However, for certain tracers, reconcentration techniques can permit the measurement of large discharges (of the order of 1 000 m3/s) where conditions of mixing and tracer loss are acceptable. b) With the exception of the conductivity method for sodium choride, the determination ranges of laboratory analysis methods are limited, so dilution of river samples may be necessary before analysis. This limitation means that the constant-rate injection method is preferable for chemical tracers (excepting the conductivity method) since determination of the peak concentrations resulting from a sudden injection would be difficult. c) Natural background levels, particularly of conductivity (resulting from dissolved solids in natural waters), may be high and variable, and this necessitates the use of a larger amount of tracer than would be apparent from a consideration of detection limits only. d) It is not possible to use a carrier, as in the case of radioactive tracers, and losses by adsorption may be serious in some cases.

Measurement of liquid flow in open channels -- Tracer dilution methods for the measurement of steady flow -- Part 3: Chemical tracers

ICS
17.120.20
CCS
发布
2014-12-25
实施

Hydrometric determinations Flow measurements in open channels using structures Guidelines for selection of structure

ICS
17.120.20
CCS
P12
发布
2014/12/24
实施
2014/12/24

Hydrometric determinations — Liquid flow in open channels and partly filled pipes — Guidelines for the application of Doppler-based flow measurements

ICS
17.120.20
CCS
发布
2014-12-24
实施

Liquid flow measurement in open channels by weirs and flumes — V-shaped broad-crested weirs

ICS
17.120.20
CCS
P12
发布
2014-12-24
实施
2014/12/24

Measurement of liquid velocity in open channels — Design, selection and use of electromagnetic current meters

ICS
17.120.20
CCS
N12
发布
2014-12-24
实施
2014/12/24



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号