29.030 磁性材料 标准查询与下载



共找到 405 条与 磁性材料 相关的标准,共 27

Pulsed field magnetometry

ICS
29.030
CCS
发布
2005-02-23
实施
2005-02-25

4.1 This test method evaluates the performance of flat-rolled magnetic materials over a wide frequency range of ac excitation with and without incremental dc bias, as used on transformers, motors, and other laminated core devices. 4.2 This test method is suitable for design, specification acceptance, service evaluation, and research. 4.3 The application of test results obtained with this test method to the design or evaluation of a particular magnetic device must recognize the influence of the magnetic circuitry upon its performance. Some specific items to consider are size, shape, holes, welding, staking, bolting, bracketing, shorting between laminations, ac waveform, adjacent magnetic fields, and stress. 1.1 This test method covers the determination of the magnetic properties of flat-rolled magnetic materials using Epstein test specimens with double-lap joints in the 25-cm Epstein frame. It covers determination of core loss, rms and peak exciting current, exciting power, magnetic field strength, and permeability. This test method is commonly used to test grain-oriented and nonoriented electrical steels but may also be used to test nickel-iron, cobalt-iron, and other flat-rolled magnetic materials. 1.2 This test method shall be used in conjunction with Practice A34/A34M and Test Method A343/A343M. 1.3 Tests under this test method may be conducted with either normal ac magnetization or with ac magnetization and superimposed dc bias (incremental magnetization). 1.4 In general, this test method has the following limitations: 1.4.1 Frequency—The range of this test method normally covers frequencies from 100 to 108201;000 Hz. With proper equipment, the test method may be extended above 108201;000 Hz. When tests are limited to the use of power sources having frequencies below 100 Hz, they shall use the procedures of Test Method A343/A343M. 1.4.2 Magnetic Flux Density  (may also be referred to as Flux Density)—The range of magnetic flux density for this test method is governed by the test specimen properties and by the available instruments and other equipment components. Normally, for many materials, the magnetic flux density range is from 1 to 15 kG [0.1 to 1.5 T]. 1.4.3 Core Loss and Exciting Power—These measurements are normally limited to test conditions that do not cause a test specimen temperature rise in excess of 50°C or exceed 100 W/lb [220 W/kg]. 1.4.4 Excitation—Either rms or peak values of exciting current may be measured at any test point that does not ......

Standard Test Method for Alternating Current Magnetic Properties of Materials Using the Wattmeter-Ammeter-Voltmeter Method, 100 to 10&x2009;000 Hz and 25-cm Epstein Frame

ICS
29.030
CCS
H21
发布
2005
实施

Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials

ICS
29.030
CCS
发布
2004-07-14
实施

Specifies minimum values for the principal magnetic properties of, and dimensional tolerances for, technically important magnetically hard materials (permanent magnets). For information purposes only, the standard provides values for the densities of the

Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials

ICS
29.030
CCS
H53
发布
2004-07
实施

This standard is Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials; Amendment 1.

Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials; Amendment 1

ICS
29.030
CCS
H53
发布
2004-05
实施

Magnetic materials - Method of measurement of the coercivity of magnetic materials in an open circuit

ICS
29.030
CCS
发布
2004-04-20
实施
2004-04-20

Magnetic materials - Specification for sintered soft magnetic materials

ICS
29.030
CCS
发布
2004-04-20
实施
2004-04-20

Establishes a classification of surface insulations for electrical steel sheet, strip and laminations according to their general composition, relative insulating ability and function. These surface insulations are either oxide layers or applied coatings.

Magnetic materials - Part 1-1: Classification - Surface insulations of electrical steel sheet, strip and laminations

ICS
29.030
CCS
H53
发布
2004-04
实施
2004-04-22

Magnetic materials - Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties.

ICS
29.030
CCS
H71
发布
2004-03-01
实施
2004-03-20

4.1 Materials Evaluation—Small single sheet testers were developed to supplement the testing of Epstein specimens for various applications. They are especially appropriate for determining the magnetic properties of samples when insufficient material is available for preparation of an Epstein specimen. Although the small specimen size is attractive, the precision of the small sheet testers is not expected to be as good as that of the test method Test Method A343/A343M. Small sheet testers are frequently used to measure the properties of both fully processed and semiprocessed nonoriented and magnetic lamination steels. Specimens of semiprocessed steels are normally subjected to an appropriate quality development anneal prior to testing. Small sheet testers may also be used to evaluate oriented electrical steels in either the as sheared or stress-relief annealed condition. 1.1 This guide covers procedures for interpreting the specific core loss and peak permeability determined using small single-sheet test systems. It is limited to single-sheet test systems that require a test specimen or coupon be cut from the material being tested and are designed such that the entire width of that test specimen is magnetized during testing. 1.2 This guide is primarily intended for measurements of the magnetic properties of flat-rolled electrical steels at frequencies of 50 Hz or 60 Hz under sinusoidal flux conditions. 1.3 This guide includes procedures to provide correlation with the 25-cm Epstein test method (Test Method A343/A343M). 1.4 The range of magnetic flux densities is governed by the properties of the test specimens and the instruments and test power source. Nonoriented electrical steels may be tested at magnetic flux densities up to about 16-kG [1.6T] for core loss. The maximum magnetic field strength for peak permeability testing is limited by the current carrying capacity of the magnetizing winding and the test power source. Single sheet testers are typically capable of testing at magnetic field strengths up to 50 Oe [4000 A/m] or more. 1.5 Within this guide, a small single sheet tester (small SST) is defined as a magnetic tester designed to test flat, rectangular sheet-type specimens. Typical specimens for these testers are square (or nearly so). The design of the small SST test fixture may be small enough to accommodate specimens about 5 by 5 cm or may be large enough to accommodate specimens about 36 by 36 cm. Specimens for a particular SST must be appropriate for the particular test fixture. 1.6 This guide covers two alternative test methods: Method 1 and Method 2. 1.6.1 Method 1 is an extension of Method 1 of Test Method A804/A804M, which describes a test fixture having two windings that encircle the test specimen and two low-reluctance, low-core loss ferromagnetic yokes that serve as flux return paths. The dimensions of the test fixture for Method 1 are not fixed but rather may be designed and built for any nominal specimen dimension within the limits given in

Standard Guide for Measuring Power Frequency Magnetic Properties of Flat-Rolled Electrical Steels Using Small Single Sheet Testers

ICS
29.030
CCS
发布
2004
实施

This test method is suitable for specification acceptance, design purposes, service evaluation, regulatory statutes, manufacturing control, and research and development. Because of the restrictions on the specimen shape and size, this test method is most often used to evaluate semifinished product before fabrication of parts.1.1 These test methods cover three procedures for determination of the permeability [relative permeability] of materials having a permeability not exceeding 4.0. 1.2 The test methods covered are as follows: 1.2.1 Test Method 1 is suitable for materials with permeabilities between 1.0 and 4.0. 1.2.2 Test Method 2 is suitable for measuring the permeability of paramagnetic materials having a permeability less than 1.05. 1.2.3 Test Method 3 is a suitable means of measuring the permeability of a material as "less than" or "greater than" that of calibrated standard inserts designated for use in a Low-Mu Permeability Indicator. 1.3 The values stated in either customary (absolute (or practical) cgs-emu and inch-pound) units or SI units are to be regarded separately as standard. Within this test method, the SI units are shown in brackets except for the sections concerning calculations where there are separate sections for the respective unit systems. The values stated in each system are not exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with this specification. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Test Methods for Permeability of Feebly Magnetic Materials

ICS
29.030
CCS
L19
发布
2004
实施

This part of IEC 60404 specifies methods for the measurement of a.c. magnetic properties of materials in the frequency range 20 Hz to 200 kHz other than electrical steels and soft ferrites. The materials covered by this part of IEC 60404 include those speciality alloys listed in IEC 60404-8-6, amorphous and nanocrystalline materials, pressed and sintered and metal injection moulded parts such as are listed in IEC 60404-8-9, cast parts and magnetically soft composite materials. The object of this part is to define the general principles and the technical details of the measurement of the magnetic properties of magnetically soft materials by means of ring met

Magnetic materials - Part 6: Methods of measurement of the magnetic properties of magnetically soft metallic and powder materials at frequencies in the range 20 Hz to 200 kHz by the use of ring specimens

ICS
29.030
CCS
发布
2003-11-07
实施
2003-09-26

This document applies to magnetic materials having a coercivity up to 500 kA/m. Special precautions to take in measuring coercivities below 40 A/m and above 160 kA/m are given in annex A.

Magnetic materials - Method of measurement of the coercivity of magnetic materials in an open magnetic circuit; German version EN 10330:2003

ICS
29.030
CCS
L19
发布
2003-09
实施
2003-09-01

This document specifies some magnetic and mechanical properties of sintered soft magnetic metals which are used for components made by a powder metallurgical process only.

Magnetic materials - Specification for sintered soft magnetic materials; German version EN 10331:2003

ICS
29.030
CCS
H72
发布
2003-09
实施
2003-09-01

Magnetic materials - Method of measurement of the coercivity of magnetic materials in an open circuit.

ICS
29.030
CCS
L19
发布
2003-08-01
实施
2003-08-20

This standard specifies some magnetic and mechanical properties of sintered soft magnetic metals which are used for components made by a powder metallurgical process only.

Magnetic materials - Specification for sintered soft magnetic materials

ICS
29.030
CCS
发布
2003-06-10
实施
2003-05-15

Standard Terminology of Symbols and Definitions Relating to Magnetic Testing

ICS
29.030
CCS
发布
2003-06-10
实施

This standard specifies the method of measurement of the coercivity of magnetic materials in an open magnetic circuit. It applies to magnetic materials having a coercivity up to 500 kA/m. Special precautions to take in measuring coercivities below 40 A/m and above 160 kA/m are given in annex A

Magnetic materials - Method of measurement of the coercivity of magnetic materials in an open circuit

ICS
29.030
CCS
发布
2003-06-10
实施
2003-05-15

This European standard specifies the method of measurement of the magnetic flux density, magnetic polarization and the magnetic field strength and also the determination of the demagnetization curve and recoil line of permanent magnet materials, such as those specified in IEC 60404-8-1, the properties of which are presumed homogeneous throughout their volume. The performance of a magnetic system is not only dependent on the properties of the permanent magnet material but also on the dimensions of the system, the air-gap and other elements of the magnetic circuit. The methods described in this standard refer to the measurement on the magnetic properties in a closed magnetic circuit simulating a ring.

Magnetic materials - Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties

ICS
29.030
CCS
H53
发布
2003-05-28
实施
2003-05-28

This European Standard specifies the method of measurement of the coercivity of magnetic materials in an open magnetic circuit. It applies to magnetic materials having a coercivity up to 500 kA/m. Special precautions to take in measuring coercivities below 40 A/m and above 160 kA/m are given in annex A.

Magnetic materials - Method of measurement of the coercivity of magnetic materials in an open circuit

ICS
29.030
CCS
H53
发布
2003-05-02
实施
2003-05-02



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved