29.060 电线和电缆 标准查询与下载



共找到 649 条与 电线和电缆 相关的标准,共 44

Inverter power cable

ICS
29.060
CCS
K12
发布
2016-03-18
实施
2016-06-18

Rated voltage 0.6/1kV (Um=1.2kV) flame-retardant and fire-resistant 125℃ irradiated XLPE insulated low-smoke halogen-free power cable

ICS
29.060
CCS
K12
发布
2016-03-18
实施
2016-06-18

Plastic Insulated Intrinsically Safe Control Cable

ICS
29.060
CCS
K12
发布
2016-03-18
实施
2016-06-18

Rated voltage 10kV steel conductor aluminum stranded conductor XLPE insulated overhead cable

ICS
29.060
CCS
K12
发布
2016-03-18
实施
2016-06-18

Self-heating heating cable

ICS
29.060
CCS
K12
发布
2016-03-18
实施
2016-06-18

Rated voltage 450750V and below radiation modified rubber compound insulated wire

ICS
29.060
CCS
K13
发布
2016-03-18
实施
2016-06-18

Rated voltage 0.61kV and below agricultural direct buried multi-core plastic insulated cables

ICS
29.060
CCS
K12
发布
2016-03-18
实施
2016-06-18

Rated voltage 1kV and below Steel core aluminum stranded core XLPE insulated overhead cable

ICS
29.060
CCS
K12
发布
2016-03-18
实施
2016-06-18

1.1 This standard describes the apparatus, test methods, and formulas to be used in carrying out the tests and calculations required by wire and cable standards. 1.2 Specific acceptance requirements are found in individual product standards. 1.3 Where a test method indicates a “specified” test parameter or condition, the parameter or condition is found in the individual product standard.

Wire and cable test methods

ICS
29.060
CCS
发布
2015-12-01
实施

Copper clad aluminum conductor plastic insulated computer cable

ICS
29.060
CCS
K 12
发布
2015-05-15
实施
2015-08-15

Ceramic silicone rubber insulated high temperature fireproof wire with rated voltage 450/750V and below

ICS
29.060
CCS
K 13
发布
2015-05-15
实施
2015-08-15

Inorganic mineral insulated flexible fireproof cables with rated voltage 0.6/1kV and below

ICS
29.060
CCS
K 12
发布
2015-05-15
实施
2015-08-15

Copper clad aluminum conductor plastic insulated control cable

ICS
29.060
CCS
K 12
发布
2015-05-15
实施
2015-08-15

This International Standard applies to cable reels for a.c. only, provided with a non-detachable flexible cable with a rated voltage above 50 V and not exceeding 250 V for single-phase cable reels and above 50 V and not exceeding 440 V for all other cable reels, and a rated current not exceeding 16 A. They are intended for household, commercial and light industrial and similar purposes, either indoors or outdoors, with particular reference to safety in normal use.

Electrical accessories - Cable reels for household and similar purposes

ICS
29.060
CCS
发布
2014-12-25
实施

This International Standard applies to cable reels provided with a non-detachable flexible cable with a rated operating voltage not exceeding 690 V a.c./d.c. and 500 Hz with a rated current not exceeding 63 A, primarily intended for industrial use, either indoors or outdoors, for use with accessories complying with IEC 60309-1 or IEC 60309-2. This standard applies to: – portable cable reels equipped with one plug or appliance-inlet and at least one socketoutlet, each complying with IEC 60309-1 or IEC 60309-2; – fixed cable reels equipped with at least one socket-outlet complying with IEC 60309-1 or IEC 60309-2; – cable reels suitable for use at ambient temperature normally within the range of –25 °C to +40 °C. The use of this equipment on construction sites and for agricultural, commercial and domestic appliances are not precluded. This standard also applies to cable reels intended to be used in extra-low voltage installations. In locations where special conditions prevail, for example, on board ships, vehicles and the like, or where explosions are liable to occur, additional requirements may be necessary. NOTE – Additional requirements for cable reels for currents higher than 63 A are under consideration.

Industrial cable reels

ICS
29.060
CCS
发布
2014-12-25
实施

This International Standard specifies the electrical and mechanical characteristics of concentric lay, overhead conductors of wires formed or shaped before, during or after stranding, made of combinations of any of the following metal wires: a) hard aluminium as per IEC 60889 designated A1; b) hard aluminium as per IEC 60889 designated A1F wire shaped before stranding; c) hard aluminium alloy as per IEC 60104 designated A2 or A3; d) hard aluminium alloy as per IEC 60104 designated A2F or A3F shaped before stranding; e) regular strength steel, designated S1A or S1B, where A and B are zinc coating classes, corresponding respectively to classes 1 and 2; f) high strength steel, designated S2A or S2B; g) extra high strength steel, designated S3A; h) aluminium clad steel, designated SA. The following are examples of some possible conductor designations. Other combinations are also permitted. • A1F, A2F, A3F • A1F/S1A, A1F/S1B, A1F/S2A, A1F/S2B, A1F/S3A • A1F/A1, A1F/A2, A1F/A3 • A1F/SA, A2F/SA, A3F/SA Other possible conductor types not included above are not specifically excluded.

Overhead electrical conductors - Formed wire, concentric lay, stranded conductors

ICS
29.060
CCS
发布
2014-12-25
实施

本标准规定了额定电压0.6/1 kV及以下金属护套无机矿物绝缘电缆及终端的术语和定义、分类、代号、规格和标记、一般规定、要求、试验方法、检验规则、标志和标签、包装、运输和贮存。本标准适用于额定电压0.6/1 kV及以下布线用金属护套无机矿物绝缘电缆及终端。

Metal sheath inorganic mineral insulated cables and their terminations with a rated voltage not exceeding 0.6/1 kV

ICS
29.060
CCS
K12
发布
2014-09-11
实施
2015-02-01

Carbon fiber flexible heating wire

ICS
29.060
CCS
K 12
发布
2014-09-02
实施
2014-10-01

Scope 1.1 This Standard specifies the requirements for single-conductor and multiple-conductor thermoset-insulated wires and cables rated 600 V, 1000 V, 2000 V, and 5000 V, for use in accordance with the rules of the Canadian Electrical Code (CEC), Part I, CSA C22.1, in Canada, Standard for Electrical Installations, NOM-001-SEDE, in Mexico, and the National Electrical Code (NEC), NFPA-70, in the United States of America. See Annex A for the complete list of types covered by this Standard and the specific electrical codes for which they are intended, and Annex B for a summary of construction and test requirements for these types. 1.2 Table 1 provides a summary of the maximum conductor temperature, voltage ratings, and the number of insulated conductors for the types to which this Standard applies. 1.3 This Standard also specifies the requirements for submersible pump cables, with or without jackets, in Clause 7. No type-letter designations are assigned to these cables. 1.4 Products within this Standard might have applications not covered by the electrical codes listed in Clause 1.1.

Thermoset-insulated wires and cables (Tri-national standard, with UL 44 and ANCE NMX-J-451-2014)

ICS
29.060
CCS
发布
2014-04-01
实施

Scope 1.1 This Standard specifies the requirements for 600 V, single-conductor, thermoplastic-insulated wires and cables, for use as follows: a) In Canada, in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I; b) In Mexico, in accordance with NOM-001-SEDE, Standard for Electrical Installations; and c) In the United States, in accordance with ANSI/NFPA 70, National Electrical Code (NEC). Note: See Annex A for the complete list of wire types covered by this Standard and the specific electrical codes for which they are intended. 1.2 This Standard also specifies the requirements for submersible-pump cables, with or without jackets (see Clause 7). No type-letter designations are assigned to these cables. 1.3 In Mexico, the requirements for multiple-conductor thermoplastic-insulated and -jacketed cables rated 600 V are specified in Annex B. In Canada and the United States, requirements for multiple-conductor thermoplastic-insulated and -jacketed cables rated 600 V are covered in other standards. 1.4 Products for which this Standard provides requirements might have applications not described in the electrical codes listed in Clause 1.1.

Thermoplastic insulated wires and cables (Tri-national standard, with UL 83 and NMX-J-010-ANCE-2010)

ICS
29.060
CCS
发布
2014-04-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved