Independent gas-fired convection heaters (Incorporates Amendment A1: 2003)

ICS
97.100.20
CCS
发布
2000
实施

This European Standard defines, for the purpose of type examination, the requirements, the test methods and the marking of non-domestic flueless space heaters (including greenhouse heaters and diffusive catalytic combustion heaters), having a nominal heat input not exceeding 10 kW (Hs) burning 3rd family gases at nominal operating pressure not exceeding 50 mbar, referred to in the body of the text as "appliances". It covers the following types of appliance: a) fixed heaters designed for installation up to 2,5 m burning commercial butane, commercial propane, or their mixtures; b) portable or mobile heaters burning commercial butane and/or commercial propane including those that incorporate a compartment for a transportable refillable liquefied petroleum gas cylinder. NOTE 1: Appliances having a nominal heat input not exceeding 4,2 kW and intended for use in domestic premises are covered by EN 449. There are no specific thermal efficiency requirements appropriate to these types of appliances as: c) all the heat produced by the combustion process is released into the space to be heated; d) the requirements with regard to the combustion performance, which is a safety matter, ensure the effective burning of the fuel gas. It does not apply to appliances which incorporate a fan for either the assistance of combustion or the circulation of convected air. Neither does it cover appliances incorporating full sequence automatic controls. Requirements for appliances given in this Standard assume that the supply of gas will be controlled by a pressure regulator giving an outlet pressure as indicated in Table A.1. Requirements for controls, given herein, relate to controls fitted as part of, or supplied with, particular appliances; they do not necessarily provide a complete specification for controls intended for general use. NOTE 2: Catalytic heaters are not considered suitable for use in areas having chemicals present which are likely to prevent the correct operation of the catalytic pad. This Standard does not cover cylinders for liquefied petroleum gases or their associated regulators.

Specification for dedicated liquefied petroluem gas appliances - Flueless non-domestic space heaters not exceeding 10 kW

ICS
97.100.20
CCS
Q83
发布
1999-12-15
实施
1999-12-15

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube heaters incorporated into a multi-burner system (called system E and referred to in the body of the text as the 'system') with each burner unit under the control of an automatic burner control system. This standard is applicable to Type B22 and Type B23 systems (see 4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This standard is not applicable to: — systems designed for use in domestic dwellings; — outdoor systems; — systems in which the heat input of an individual burner unit exceeds 120 kW (based on the net calorific value of the appropriate reference test gas); — systems having a draught diverter incorporated between the exhaust fan and the flue duct; — systems having fully pre-mixed gas and air burners in which: — either the gas and all the combustion air are brought together just before the level of the combustion zone; — or the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone. This European Standard is applicable to systems which are intended to be type tested. Requirements for systems which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - System E, safety

ICS
97.100.20
CCS
Q83
发布
1999-12-15
实施
1999-12-15

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube heaters incorporated into a multi-burner system (called system D and referred to in the body of the text as the "system") with each burner unit under the control of an automatic burner control system. This standard is applicable to Type B22 systems (see 4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means. This standard is not applicable to: — systems designed for use in domestic dwellings; — outdoor systems; — systems in which the heat input of an individual burner unit exceeds 120 kW (based on the net calorific value of the appropriate reference test gas); — systems having a draught diverter; — systems having fully pre-mixed gas and air burners in which: either the gas and all the combustion air are brought together just before the level of the combustion zone; or the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone. This European Standard is applicable to systems which are intended to be type tested. Requirements for systems which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - System D, safety

ICS
97.100.20
CCS
Q83
发布
1999-12-15
实施
1999-12-15

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas fired overhead radiant tube heaters incorporating a single burner system under the control of an automatic burner control system, referred to in the body of the text as "appliances". This standard is applicable to Type A2, A3, B12, B13, B22 and B23 appliances intended for use in other than domestic dwellings, in which the supply of combustion air and/or the evacuation of the products of combustion is achieved by mechanical means located upstream of the draught diverter, if provided. This standard is not applicable to: —appliances designed for use in domestic dwellings; —outdoor appliances; —appliances of heat input in excess of 120 kW (based on the net calorific value of the appropriate reference test gas); —appliances having fully pre-mixed gas and air burners in which: —either the gas and all the combustion air are brought together just before the level of the combustion zone; —or the pre-mixing of the gas and all combustion air is carried out in a part of the burner upstream of the combustion zone. This standard is applicable to appliances which are intended to by type tested. Requirements for appliances which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Single burner gas-fired overhead radiant-tube heaters - Safety

ICS
97.100.20
CCS
Q83
发布
1999-12-15
实施
1999-12-15

This European Standard specifies the requirements and test methods for the construction, safety, classification and marking of non-domestic gas-fired overhead radiant tube systems incorporating two or more burner units with each burner under the control of an automatic burner control system, and operated by a single fan providing a single flue outlet, called system H and referred to in the body of the text as the "system". This standard is applicable to Type B22 systems (see 4.3) intended for use in other than domestic dwellings, in which the supply of combustion air and the evacuation of the products of combustion is achieved by mechanical means. This standard is applicable only to such systems that have fully pre-mixed gas/air burners. This standard is not applicable to: —systems designed for use in domestic dwellings; —outdoor systems; —systems in which the heat input of an individual burner unit exceeds 120 kW (based on the net calorific value of the appropriate reference test gas); —systems having a draught diverter. This European Standard is applicable to systems which are intended to be type tested. Requirements for systems which are not intended to be type tested would need to be subject to further consideration. Requirements concerning the rational use of energy have not been included in this European Standard.

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - System H, safety

ICS
97.100.20
CCS
Q83
发布
1999-10-15
实施
1999-10-15

Specification for dedicated liquefied petroleum gas appliances - Mobile and portable non-domestic forced convection direct fired air heaters

ICS
97.100.20
CCS
发布
1999-10-01
实施
1999-10-01

1.1 Scope 1.1.1 This standard applies to newly produced, direct gas-fired industrial air heaters of the non-recirculating type, hereinafter referred to as heaters, whose purpose is to offset building heat loss. All air to the heater shall be ducted directly from outdoors and the products of combustion generated by the heater are released into the air stream being heated. Heaters covered by this standard are intended for use in industrial and commercial applications. Heaters covered by this standard are not intended for use in any area containing sleeping quarters. The installation shall conform with local codes, or in the absence of local codes, in accordance with the National Fuel Gas Code, ANSI Z223.1, or the CAN/CGA B149, Installation Codes. This standard applies to heaters designed for heated discharge air temperature of 160°F (71°C) or less. This standard is intended to cover only complete packaged heaters with integral air moving components, i.e., those which are designed by, cataloged by and built on a repetitive basis by the manufacturer. 1.1.2 If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.3 Items unique to the U.S. are shown in Exhibit A. 1.1.4 Items unique to Canada are shown in Exhibit B. 1.1.5 Exhibit C contains a list of standards specifically referenced in this standard, and sources from which these referenced standards may be obtained.

Non-Recirculating Direct Gas-Fired Industrial Air Heaters

ICS
97.100.20
CCS
发布
1999-10-01
实施

Specification for dedicated liquefied petroleum gas appliances - Flueless non-domestic space heaters not exceeding 10 kW (Incorporates Amendment A1: 2004)

ICS
97.100.20
CCS
发布
1999-09-01
实施

Multi-burner gas-fired overhead radiant tube heater systems for non-domestic use - Part 4 : system H, safety.

ICS
97.100.20
CCS
J98
发布
1999-08-01
实施
1999-08-05

1.1 Scope 1.1.1 These requirements apply to manually lighted, natural gas, decorative gas appliances for installation in solid-fuel burning fireplaces, (see Part IV, Definitions), hereinafter referred to as appliances, for use with natural gas only, at a maximum input rating of 90,000 Btu/hr (except as noted in 1.7, Piezo-Electric Ignitors), which are constructed entirely of new, unused parts and materials. These appliances do not incorporate a pilot burner or an automatic gas ignition system. The main burner(s) is intended to be lighted by hand each time the appliance is used. The construction of manually lighted, natural gas, decorative gas appliances for installation in solid-fuel burning fireplaces is covered under Part I. The performance of manually lighted, natural gas, decorative appliances for installation in solid-fuel burning fireplaces is covered under Part II. 1.1.2 Manually lighted, natural gas, decorative appliances for installation in solid-fuel burning fireplaces shall not be thermostatica lly controlled. 1.1.3 This standard does not cover unvented room heaters. 1.1.4 The use of the term appliance henceforth in this standard is in reference to a manually lighted, natural gas, decorative gas appliance for installation in a solid-fuel burning fireplace. 1.1.5 If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.6 Exhibit B (List of Reference Standards) contains a list of standards specifically referenced in this standard and sources f rom which they may be obtained. It is the responsibility of the user of this Standard to determine which referenced standard applies based on the requirements of the authority having jurisdiction at the location of the installation.

Manually Lighted, Natural Gas, Decorative Gas Appliances for Installation in Solid-Fuel Burning Appliances

ICS
97.100.20
CCS
发布
1999-02-23
实施

Decorative fuel-effect gas appliances (Incorporates Amendments A1: 2003 and A2: 2004)

ICS
97.100.20
CCS
发布
1999
实施

This standard defines, for the purpose of type examination, the construction, the safety characteristics, the test methods and the marking of mobile and portable non-domestic forced convection direct fired air heaters with a rated heat input not exceeding 180 kW (Hs) and burning third family gases, referred to in the body of the text as "appliances". This standard covers the following type of mobile and portable non-domestic forced convection direct fired air heaters of type A3 (see CR 1749) fitted with an integral burner intended for use in other than residential dwellings: a) low gas pressure appliances operating at pressures up to and including 50 mbar burning commercial butane and/or commercial propane; b) medium gas pressure appliances operating at pressures above 50 mbar and up to 4,0 bar burning commercial butane and/or commercial propane. It does not apply to appliances which are intended to be fixed or permanently installed, or to appliances which incorporate liquid feed burners. Requirements for appliances given in this standard assume that the supply of gas from the gas cylinder will be governed by a pressure regulator. These appliances are not equipped with an appliance governor. Requirements for controls, given herein, relate to controls fitted as part of, or supplied with, particular appliances; they do not necessarily provide a complete specification for controls intended for general use. This standard does not cover cylinders for liquefied petroleum gases or their associated regulators. There are no specific thermal efficiency requirements appropriate to these types of appliances as: c) all the heat produced by the combustion process is released into the space to be heated; d) the requirements with regard to the combustion performance, which is a safety matter, ensure the effective burning of the fuel gas.

Specification for dedicated liquefied petroleum gas appliances - Mobile and portable non-domestic forced convection direct fired air heaters

ICS
97.100.20
CCS
Q82
发布
1998-12-15
实施
1998-12-15

This standard specifies the additional requirements and test methods for gas-fired air heaters which are so designed that water vapour condenses from combustion products. On this subject it extends the European Standards EN 778 and EN 1319 for domestic, and EN 621 and EN 1020 for non-domestic air heaters. This standard applies to gas-fired air heaters with or without a fan in the combustion circuit in one of the following constructional types: —an integral air heater with at least one condensing heat exchanger; —a non-condensing air heater with an integrated additional condensing heat exchanger; —a non-condensing air heater, with an integrated additional condensing heat exchanger for the recovery of heat from combustion products and from ventilation air if appropriate. This European Standard covers type-testing only.

Domestic and non-domestic gas-fired air heaters - Supplementary requirements for condensing air heaters

ICS
97.100.20
CCS
Q83
发布
1998-11-15
实施
1998-11-15

Domestic and non-domestic gas-fired air heaters. Supplementary requirements for condensing air heaters.

ICS
97.100.20
CCS
J98
发布
1998-09-01
实施
1998-09-20

1.1 SCOPE 1.1.1 This standard applies to newly produced vented gas fireplace heaters (See Part IV, Definitions), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials: a. For use with natural gas; b. For use with propane; c. Direct vent appliances for manufactured (mobile) home OEm installation or aftermarket installation convertible for use with natural gas and propane when provision is made for simple conversion from one gas to the other (See 1.2.4-a); d. Direct vent appliances for manufactured (mobile) home aftermarket installation only for use with natural gas and propane. (See 1.2.4-b); e. Direct vent appliances for recreational vehicle installation for use with propane gases only. (See 1.2.4-c); and f. Direct vent appliances for recreational vehicle installation only convertible for use with natural gas and propane gases when provision is made for the simple conversion from one gas to the other. (See 1.2.4-c) The construction of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Part I (Construction). The performance of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Part II (Performance). 1.1.2 Exhibit A, (Automatic Intermittent Pilot Ignition Systems for Field Installation), includes provisions for newly produced (optional) automatic intermittent pilot ignition systems (See Part IV, Definitions), constructed entirely of new, unused parts and materials, to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance. 1.1.3 If a value for measurement given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. 1.1.4 This standard covers the thermal efficiency and related markings of only those appliances whose efficiencies are not regulated in the U.S.A. by the Energy Policy and Conservation Act of 1975 and the National Energy Conservation Policy Act of 1978* or covered in Canada by Exhibit B, Items Unique to Canada. 1.1.5 Exhibit B, Items Unique to Canada, contains provisions that are unique to Canada. 1.1.6 Exhibit C, Items Unique to the United States, contains provisions that are unique to the United States. 1.1.7 This standard also applies to appliances with draft hoods which are factory equipped with automatic vent damper devices (See Part IV, Definitions), hereinafter referred to as vent damper devices. 1.1.8 Special construction provisions applicable to vented gas fireplace heaters designed for use with an optional design-certified conversion kit are outlined under Exhibit D, (Optional) Provisions for Listed Gas Appliance Conversion Kits. 1.1.9 Exhibit E, (List of Reference Standards), contains a list of standards specifically referenced in this standard, and sources from which they may be obtained. * At the time of this printing, the above acts regulate the thermal efficiency (heating capacity) of vented appliances. For information, contact the U.S. Department of Energy, Conservation and Solar Applications, Consumer Products Efficiency Branch, 20 Massachusetts Avenue, N.W., Washington, DC 20545.

Vented Gas Fireplace Heaters

ICS
97.100.20
CCS
发布
1998-06-30
实施

This European Standard specifies the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters having a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This includes appliances having forced draught burners. This European Standard applies to Type B12, B13, B14, B22, B23, C12, C13, C32, C33, C62 and C63 appliances with a heat input not exceeding 300 kW (based on net calorific value) intended for use in other than single unit residential dwellings. It also applies to appliances intended for outdoor installation. Provision of the heated air may be by means of ducting or may be directly into the heated space. For Type B22 appliances, this European Standard only applies to appliances having automatic ignition. For Type C62 and C63 appliances, this European Standard only applies when such appliances are intended for final installation in a similar manner to Type C3 appliances. This standard does not apply to: - appliances intended for use in a single unit residential dwelling; - appliances of the condensing type; - appliances with atmospheric burners without a fan to assist the transportation of combustion air and/or flue gases; - dual purpose air conditioning appliances (heating and cooling); - appliances where the air is heated by an intermediate fluid; - appliances fitted with manual or automatic flue dampers; - portable or transportable forced convection appliances; - appliances having multiple heating units with a single draught diverter; - appliances fitted with more than one flue outlet. This European Standard is applicable to appliances which are intended to be type tested. NOTE Requirements for appliances which are not type tested would need to be subject to further consideration.

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, incorporating a fan to assist transportation of combustion air and/or combustion products

ICS
97.100.20
CCS
Q83
发布
1998-06-15
实施
1998-06-15

This standard defines, forThe purpose of type examination,The construction,The safety characteristics,The test methods andThe marking of mobile and portable non-domestic forced convection direct fired air heaters with a rated heat input not exceeding 180 kW (Hs) and burning third family gases, referred to inThe body of the text as "appliances".

Specification for dedicated liquefied petroleum gas appliances - Mobile and portable non-domestic forced convection direct fired air heaters

ICS
97.100.20
CCS
发布
1998-06-01
实施

Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW, without a fan to assist transportation of combustion air and/or combustion products.

ICS
97.100.20
CCS
Q83
发布
1998-05-01
实施
1998-05-20

Non-domestic gas-fired forced convection air heaters for space heating not exceeding ? net heat input of 300 kW, incorporating an fan to assist transportation of combustion air and/or combustion products.

ICS
97.100.20
CCS
J98
发布
1998-04-01
实施
1998-04-05