共找到 345 条与 放大镜与显微镜 相关的标准,共 23 页
This standard applies to any intraocular lens (IOL) whose primary indication is the modification of the refractive power of a phakic eye. It does not include IOLs used to correct presbyopia or astigmatism. This standard addresses the vocabulary, optical
Phakic Intraocular Lenses
この規格は,光学顕微鏡における対物レンズ,接眼レンズなど結像要素の一連の倍率値について規定する。
Microscopes -- Magnification
この規格は,観察用の単眼鏡筒及び双眼鏡筒を除く顕微鏡結像射出口用のCマウント接続ねじの寸法及び一次像面位置について規定する。
Microscopes -- Interfacing connection type C
この規格は,顕微鏡の製造業者が顕微鏡使用者に提供すべき最低限の仕様項目について規定する。なお,必す(須)の項目には(m),推奨する項目には(r)を,それぞれの項目の前に記す。
Microscopes -- Information provided to the user
This part of ISO 10934 specifies terms and definitions to be used in the field of advanced light microscopy.
Optics and optical instruments - Vocabulary for microscopy - Part 2: Advanced techniques in light microscopy
This part of ISO 11884 specifies minimun requirements for high performance stereomicroscopes.It is not applicable to operation microscopes.
Optics and photonics - Minimum requirements for stereomicroscopes - Part 2: High performance microscopes
ISO 14880-2:2006 specifies methods for testing wavefront aberrations for microlenses within microlens arrays. It is applicable to microlens arrays with very small lenses formed inside or on one or more surfaces of a common substrate.
Optics and photonics - Microlens arrays - Test methods for wavefront aberrations
Optics and phonotics - Microlens arrays - Part 4 : test methods for geometrical properties.
This standard specifies methods for testing geometrical properties of microlenses in microlens arrays. It is applicable to microlens arrays with very small lenses formed on one or more surfaces of a common substrate and to graded index microlenses.
Optics and photonics - Microlens arrays - Part 4: Test methods for geometrical properties (ISO 14880-4:2006) English version of DIN EN ISO 14880-4:2006-08
This standard specifies methods for testing optical properties, other than wavefront aberrations, of microlenses in microlens arrays. It is applcable to microlens arrays with very small lenses formed on one or more surfaces of a common substrate and to graded index microlenses.
Optics and photonics - Microlens arrays - Part 3: Test methods for optical properties other than wavefront aberrations (ISO 14880-3:2006) English version of DIN EN ISO 14880-3:2006-08
ISO 14880-3:2006 specifies methods for testing optical properties, other than wavefront aberrations, of microlenses in microlens arrays. It is applicable to microlens arrays with very small lenses formed on one or more surfaces of a common substrate and to graded index microlenses.
Optics and photonics - Microlens arrays - Test methods for optical properties other than wavefront aberrations
ISO 14880-4:2006 specifies methods for testing geometrical properties of microlenses in microlens arrays. It is applicable to microlens arrays with very small lenses formed on one or more surfaces of a common substrate and to graded index microlenses.
Optics and photonics - Microlens arrays - Test methods for geometrical properties
This International Standard describes the characteristics of immersion liquids used in microscopy. It classifies immersion liquids according to their field of application and specifies requirements and test methods for each type. This International Standard further specifies a system of designation for immersion liquids, the information to be included on container labels and the information to be supplied in technical data sheets.
Optics and photonics - Microscopes - Immersion liquids for light microscopy
이 규격은 현미경의 대물렌즈를 노즈피스에 연결하는 나사의 한 유형인 RMS 나사산의 치 수
Optics and optical instruments-Microscopes-Screw threads for objectives and related nosepieces-Part 1:Screw thread type RMS(4/5 in×1/36 in)
이 규격은 전 제조업체에 의해 제조되는 현미경에 장착되는 보조 광학 및 보상기의 상호 교
Optics and optical instruments-Microscopes-Dimensions of tube slide and tube slot connections
이 규격은 기계적인 경통 길이가 160 mm이거나 이와 동일한 현미경의 대물렌즈 및 접안
Optics and optical instruments Microscopes - Imaging distances related to mechanical reference planes - Part 1 Tube length 160 mm
이 규격은 광학 현미경의 상(image) 구성 요소들의 배율에 대한 일련의 값을 규정하고
Optics and optical instruments Microscopes Magnification
이 규격은 현미경의 대물렌즈를 노즈피스에 연결하는 RMS 나사산 이외의 다른 유형인 M25
Optics and optical instruments-Screw threads for microscope objectives and related nosepieces-Part 2:Screw thread type M25×0.75 mm
이 규격은 무한보정 광학계가 장착된 현미경의 대물렌즈와 접안렌즈의 상거리 및 “정상” 경
Optics and optical instruments-Microscopes:Imaging distances related to mechanical reference planes-Part 2:Infinity-corrected optical systems
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号