赛默飞Thermo PepSwift Columns离子色谱IC柱

赛默飞Thermo PepSwift Columns离子色谱IC柱

产品参数

货号 规格 操作
更多货号咨询>>
关闭

服务地域:全国

属性:产地:美国; 品牌:赛默飞 ;货期:现货

上海希言科学仪器有限公司

普通会员 普通会员
推荐产品推荐产品
产品描述产品描述

Monolithic Columns for Fast, High-Resolution Protein and Peptide Analysis

PepSwift monolithic columns are specially designed for fast separation and identification of proteins and peptides using nano and capillary LC coupled to MS. PepSwift columns are based on a polystyrene divinylbenzene copolymer bed. The bed structure of the column offers a high-quality alternative to traditional microparticulate sorbents, providing important advantages for high-sensitivity proteomics applications.

  • Polymeric monolithic stationary phases

  • High-speed protein/peptide separations (< 10 min)

  • High separation efficiency (> 200.000 plates/m)

  • High column-to-column reproducibility

  • High sensitivity in LC/MS

  • Superior lifetime

  • Available in 100 μm, 200 μm and 500 μm i.d

  • Available in 5 and 25 cm length (only 100 and 200 µm i.d.)

  • nanoViper fitting

PepSwift Trap columns can be used for preconcentration and desalting of samples consisting of peptides and proteins without negative impact on the chromatographic performance or recovery of the compounds. Various ion-pairing agents can be used in the loading solvent and/or mobile phases to change the selectivity of the separation or improve the trapping efficiency.



PepSwift and ProSwift Capillary Monolithic Reversed-Phase Columns Specifications

PepSwift RP
Typical ApplicationsPeptides, proteins, and oligonucleotides
Column Dimensions100 μm × 50 mm200 μm × 50 mm500 μm × 50 mm
Base MaterialPolystyrene/divinyl benzenePolystyrene/divinyl benzenePolystyrene/divinyl benzene
ChemistryPhenylPhenylPhenyl
Recommended Flow Rate700–1000 nL/min2–3 μL/min15–25 μL/min
Temperature80 ˚C80 ˚C80 ˚C
Maximum Pressure4350 psi (30 MPa)4350 psi (30 MPa)4350 psi (30 MPa)
Recommended Sample Quantity5 ng*20 ng*0.12 μg*
Sample Capacity***0.2 ng0.6 ng3.8 ng
pH Stability1–101–101–10
Solvent CompatibilityMost common RP
solvents
Most common RP
solvents
Most common RP
solvents

*Tryptic digest of six proteins
**E. coli proteins
*** Dynamic loading capacity is defined as the 10% increase in peak width measured at half height induced by injected mass of a single peptide (tryptic peptide of cytochrome c for PepSwift RP) and intact protein (cytochrome c for ProSwift RP-10R), respectively



Separation of a peptide test mixture. Figure on separation on 1m long monolith.

Peak Width at Half Height (PWHH) for peptide separation.

Comparison of the influence of FA and TFA on separation of a peptide mixture.

Fast separation of tryptic peptides from 13 proteins. Peak capacities of up to 150 peaks in less than 15 min are routinely observed.

Ultra-high Resolution Separation of Tryptic Peptides on a 1m long PS-DVB Monolithic Column (4 × 25 cm)

PepSwift and ProSwift Monolith Columns
PepSwift Monolithic Nano Column, 100 μm i.d. × 5 cm, nanoViper164584
PepSwift Monolithic Nano Column, 100 μm i.d. × 5 cm, nanoViper164584
PepSwift Monolithic Nano Column, 100 µm i.d. x 25 cm, nanoViper164543
PepSwift Monolithic Capillary Column, 200 μm i.d. × 5 cm161409
PepSwift Monolithic Capillary Column, 200 µm i.d. x 5 cm, nanoViper164557
PepSwift Monolithic Capillary Column, 200 µm i.d. x 25 cm, nanoViper164542
PepSwift Monolithic Capillary Column, 500 μm i.d. × 5 cm164087
PepSwift Monolithic Capillary Column, 500 μm i.d. × 5 cm, nanoViper164585
ProSwift RP-10R Monolithic Capillary Column, 1 mm i.d. × 5 cm, nanoViper164586
ProSwift RP-10R Monolithic Capillary Column, 1 mm i.d. × 5 cm, nanoViper164586
PepSwift Trap Columns
PepSwift Monolithic Trap Column, 200 µm x 5 mm, (set of 2), nanoViper164558
PepSwift Monolithic Trap Column, 200 µm x 5 mm, (set of 2), nanoViper164558


AI问答 配套的仪器设备? X
店铺 店铺 咨询留言 咨询留言 热线电话 热线电话