For Specialized Amino Acid Applications with Postcolumn Derivatization

The AminoPac®PA1 column is a high-speed, pellicular, strong, anion-exchange column. The PA1 delivers high-efficiency separations as a result of its nonporous-core particle. Its strong anion-exchange characteristics are imparted by agglomerating surface MicroBead™ particles that are functionalized with the quaternary ammonium functional group, resulting in a higher capacity than typically offered by nonporous resins.

  • Resolves phosphorylated and other amino acids by anion-exchange chromatography

  • Separates acid-labile amino acids under basic pH conditions

  • Separates strongly acidic amino acids

  • Requires OPA or ninhydrin postcolumn derivatization

The anion-exchange selectivity of the AminoPac PA1 can be used to resolve peaks that cannot be resolved using a cation-exchange column. For example, O-phosphorylated amino acids are resolved and eluted near the end of a hydrolysate chromatogram. Arogenic acid, a precursor to tyrosine and phenylalanine, decomposes under the acidic conditions required for cation-exchange separation or PITC derivatization, but it is stable in alkaline eluents used with AminoPac PA1 column.

The PA1 is particularly well suited for acidic and acid-labile amino acids and for amino acid pairs not completely resolved by cation-exchange chromatography.


AminoPac PA1 Column for Specialized Amino Acid Applications with Postcolumn DerivatizationSpecifications
DimensionsAminoPac PA1 Analytical Column:
4×250 mm
AminoPac PA1 Guard Column:
4 × 50 mm
Maximum operating pressure4000 psi (27.9 MPa)
Recommended operating temperatureAmbient
Typical operating conditions1.0 mL/min gradient
Recommended flow rate: 1.0 mL/min
Mobile phase compatibilityCompatible with up to 5% common organic solvents.
Recommended eluents: hydroxide, borate, and acetate.
Resin composition10-µm-diameter, pellicular substrate (2% cross-linked)
agglomerated with a 180 nm MicroBead alkyl quaternary ammonium functionalized latex (20% cross-linked).
Anion-exchange capacityN/A
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.



Gradient sepration of amino acid hydrolysate.

Amino Acids by Anion Exchange Using The AminoPac®PA1 Column.

Anion-Exchange Separation ofO-Phosphorylated Amino Acids Using the AminoPac®PA1 Column.


Analytical Columns
AminoPac PA1 Analytical Column (4 x 250 mm)037022
Guard Columns
AminoPac PA1 Guard Column (4 x 50 mm)037023


AI问答 配套的仪器设备? X
店铺 店铺 咨询留言 咨询留言 热线电话 热线电话