This part of IEC 61810 states the test and measurement procedures for electromechanical
elementary relays. It covers basic considerations which are, in general, common to all types
of electromechanical elementary relays. Supplementary requirements may be necessitated by
specific designs or application.
The test and measurement procedures of this standard are described as individual provisions
covering a specific requirement. When combining them in a test programme, care must be
taken (for example by suitable grouping of tested relays) to ensure that preceding tests do
not devalue subsequent ones.
Where in this standard the term “specified” is used, this means a prescription in the
appropriate documentation for the relay, for example manufacturer’s data sheet, test
specification, customer detail specification. For application within the IECQ system such
prescriptions are contained in the detail specification as defined in Clause A.7 of QC 001001.
NOTE 1 To improve the readability of this standard, the term “relay” is generally used in place of
“electromechanical elementary relay”.
NOTE 2 Requirements and tests related to the type testing of electromechanical elementary relays are contained
in IEC 61810-1. For that purpose, the generally described test and measurement procedures of this standard have
been prescribed in a more restricted and stringent form in IEC 61810-1.
NOTE 3 Standards covering relays subjected to quality assessment in accordance with IECQ are compiled in the
IEC 61811 series of publications.