27.200 制冷技术 标准查询与下载



共找到 695 条与 制冷技术 相关的标准,共 47

本文件规定了全封闭转子式制冷泵(以下简称泵)的术语和定义、产品型式和基本参数、工作环境、技术要求、试验方法、检验规则、标志、包装、运输、贮存等。

Hermetic rotor refrigerant pump

ICS
27.200
CCS
C381
发布
2023-08-16
实施
2023-08-25

本文件规定了集中式制冷设备运维管理要求的术语和定义、设备结构、日常管理、巡视检查与维护、异常与故障处理、安全管理。

Requirements for operation and maintenance management of centralized refrigeration equipment

ICS
27.200
CCS
C346
发布
2023-08-04
实施
2023-08-18

Performance rating of Positive Displacement Refrigerant Compressor

ICS
27.200
CCS
发布
2023-08
实施

Performance rating of Centrifugal Refrigerant Compressor

ICS
27.200
CCS
发布
2023-08
实施

1范围 2规范性引用文件 3 术语和定义 4 总则 5 热管 6 氟泵与机械制冷循环  7 蒸发冷凝 8智能控制 9系统安全要求 10试验工况与能效评价 11检验与安装

Data center evaporative condensing fluorine pump heat pipe air conditioner technical specification

ICS
27.200
CCS
C359
发布
2023-06-14
实施
2023-06-14

一种向密闭空间、房间或区域提供经过处理空气的设备,热源侧采用水蒸发冷却冷凝器。它主要包括制 冷系统、水循环系统、空气循环和净化装置,还可包括加热、加湿和通风装置。

Evaporative condensing air handling unit

ICS
27.200
CCS
C349
发布
2023-06-01
实施
2023-07-01

规定了低温冷水机组的基本参数、工作条件、性能、安全、材料等技术要求,描述了试验方法,确立了相应的检验规则,规定了标志、包装、运输和贮存。

Low temperature chiller

ICS
27.200
CCS
C349
发布
2023-05-30
实施
2023-05-30

本文件规定了全自动子弹冰块制冰机的术语和定义、型式与基本参数、技术要求、试验方法、检验规则、标志、包装、运输和贮存。

Automatic bullet ice machines

ICS
27.200
CCS
C389
发布
2023-05-25
实施
2023-05-31

本文件规定了渔船卧式液压平板冻结机的操作要求。 本文件适用于渔船卧式液压平板冻结机。

Operation instruction for horizontal hydraulic contact freezer of fishing vessel

ICS
27.200
CCS
A042
发布
2023-05-18
实施
2023-08-18

  Scope is not provided for this standard

Standard Guide for Design and Maintenance of Low-Temperature Storage Facilities for Maintaining Cryopreserved Biological Materials

ICS
27.200
CCS
发布
2023-05-03
实施

本标准规定了翅片式冷凝器通用技术规范的术语和定义、基本参数、技术要求、试验方法、检验规则、标志、包装、运输和贮存。 本标准适用于翅片式冷凝器的生产及检验。

General technical specifications for finned condensers

ICS
27.200
CCS
C346
发布
2023-04-26
实施
2023-05-11

本文件规定了双冷源冷水(热泵)机组(以下简称“机组”)的术语和定义、型式与基本参数、要求、试验方法、检验规则、标志、包装和贮存等。 本文件适用于制冷量50kW以上的,以电动机驱动的采用蒸气压缩制冷循环的双冷源冷水(热泵)机组。

Dual cold source chiller (heat pump) unit

ICS
27.200
CCS
C419
发布
2023-02-24
实施
2023-03-17

本文件规定了数据中心和5G基站用空气调节机(以下简称“机组”)在进行安全性、环境适应性与可靠性试验时的测试要求和检验方法等内容。 本文件适用于机房空调、基站空调和单元式空气调节机。其它类似产品可参照执行。

Reliability evaluation method for air conditioners used in data centers and base stations

ICS
27.200
CCS
C419
发布
2023-02-24
实施
2023-03-09

This document specifies the terms, definitions, test conditions, test methods and requirements for rating the performance of air conditioners and liquid chilling packages, with electrically driven compressors and with evaporatively cooled condenser when used for space cooling. The evaporatively cooled condenser is cooled by air and by the evaporation of external additional water. This additional external water is fed by a specific water supply circuit or by a water tank. This document is not applicable to air-to-air and air-to-water air conditioners with a condenser cooled by air and by the evaporation of water condensed on their evaporator. This document is applicable to units equipped with a water tank or with a continuous water circuit supply that can also operate without water feeding. However, this document only concerns the testing of these units with water feeding. This document is applicable to factory-made units which can be ducted. This document is applicable to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by this document. With regard to units consisting of several parts, this document applies only to those designed and supplied as a complete package. For evaporatively cooled condenser units that can also operate in heating mode, their performance in this mode is determined according to EN 14511:2022 (all parts). Units used for industrial processes cooling are not within the scope of this document. This document specifies the conditions for which performance data will be declared for compliance with the Ecodesign Regulation 206/2012 and with the Energy Labelling Regulation 626/2011 of air conditioners with evaporatively cooled condenser in cooling mode. NOTE All the symbols given in this text can be used regardless of language.

Air conditioners and liquid chilling packages with evaporatively cooled condenser and with electrically driven compressors for space cooling - Terms, definitions, test conditions, test methods and requirements

ICS
27.200
CCS
发布
2022-12-21
实施
2023-03-31

本文件规定了柜级制冷产品的系统组成及分类、产品配置原则、产品技术要求、安装要求和安装工程验收。 本文件适用于新建、扩建和改造的无线基站、传输汇聚机房等场景应用的柜级制冷产品。

Application requirements for cabinet air conditioning product

ICS
27.200
CCS
C346
发布
2022-12-16
实施
2022-12-16

本文件规定了热泵热水机用同轴套管式冷凝器(以下简称“冷凝器”)的术语和定义、基本参数、基本要求、技术要求、试验方法、检验规则、标志、包装、运输和贮存及质量承诺。 本文件适用于以 R22、 R410A 和 R32 为制冷剂,水为载冷剂的热泵热水机用同轴套管式冷凝器。

Coaxial heat condenser for heat pump water heater

ICS
27.200
CCS
C346
发布
2022-12-08
实施
2023-02-24

本文件规定了商用制冷设备用电磁阀(以下简称“电磁阀”)的术语和定义、型式、型号和基本参数、基本要求、技术要求、试验方法、 检验规则、标志、包装、运输和贮存、质量承诺等内容。 本文件适用于 R22、 R134a、 R410A、 R404A、 R407C、 R507、 R507A 为制冷剂的液管、高低压蒸汽管路用公称通径 6 mm~80 mm 的电磁阀,使用其他制冷剂及类似用途的电磁阀可参照使用。

Solenoid valve for commercial refrigerantion equipment

ICS
27.200
CCS
C346
发布
2022-12-08
实施
2023-04-06

本文件规定了小型制冷系统用电动切换阀(以下简称“电动阀”)的术语和定义、型号和使用条件、基本要求、技术要求、试验方法、检验规则、标志、包装、运输和贮存、质量承诺。 本文件适用于阀口径不大于1.2 mm、采用R600a、 R134a或类似热力性质的制冷剂的制冷系统用电动切换阀。

Step valve for small refrigeration system

ICS
27.200
CCS
C346
发布
2022-12-08
实施
2023-04-06

物联网智能连续出冰式海水制冰机的型式与基本参数、要求、试验方法、检验规则、标志、包装、运输和贮存

Internet of Things intelligent continuous ice out seawater ice maker

ICS
27.200
CCS
C356
发布
2022-11-30
实施
2022-12-01

满液式水冷螺杆冷水机组的基本参数、工作条件、性能、安全、材料等技术要求,描述了试验方法,确立了相应的检验规则,规定了标志、包装、运输和贮存。

Full liquid water-cooled screw chillers

ICS
27.200
CCS
C354
发布
2022-11-08
实施
2022-11-08