33.180.20 纤维光学和光学互连器件 标准查询与下载



共找到 3544 条与 纤维光学和光学互连器件 相关的标准,共 237

IEC 61300-2-54:2019 is to assess the corrosive effects of atmospheres polluted with mixed gas on fibre optic devices. It can be considered as a general corrosion test, but it does not predict the performance of a device in use. Keywords: mixed gas on fibre optic devices

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-54: Tests - Corrosive atmosphere (mixed gas)

ICS
33.180.20
CCS
发布
2019-12-20
实施
2020-03-18 (7)

What is BS EN IEC 61300 ‑ 3 ‑ 21 - Spatial switch about? BS EN IEC 61300 is a series on fibre optic interconnecting devices and passive components. The broad variety of passive optical components applications include multichannel transmission, distribution, optical taps for monitoring, pump combiners for fibre amplifiers, bit-rate limiters, optical connects, route diversity, polarization diversity, interferometers, and coherent communication. BS EN IEC 61300 ‑ 3 ‑ 21 describes a method to measure the switching time and related performance parameters of a fibre optic spatial switch when the actuation energy is applied or removed to change the state of the switch. Who is BS EN IEC 61300 ‑ 3 ‑ 21 - Spatial switch for ? BS EN IEC 61300 ‑ 3 ‑ 21 on fibre optic interconnecting...

Fibre optic interconnecting devices and passive components. Basic test and measurement procedures - Examinations and measurements. Switching time

ICS
33.180.20
CCS
发布
2019-11-30
实施
2019-11-30

IEC 61300-3-21:2019 is available as IEC 61300-3-21:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61300-3-21:2019 describes a method to measure the switching time and related performance parameters of a fibre optic spatial switch when the actuation energy is applied or removed to change the state of the switch. This third edition cancels and replaces the second edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - changes to remove redundant overlap with IEC 60876-1; - clarifications to definitions and diagrams; - generalization of the detection apparatus beyond an oscilloscope. Keywords: switching time, performance parameters of a fibre optic spatial switch, actuation energy

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-21: Examinations and measurements - Switching time

ICS
33.180.20
CCS
发布
2019-11-15
实施
2020-01-25 (7)

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-54: Tests - Corrosive atmosphere (mixed gas)

ICS
33.180.20
CCS
发布
2019-11-13
实施

Optical fiber array for planar optical waveguide devices

ICS
33.180.20
CCS
M33
发布
2019-11-11
实施
2020-01-01

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-21: Examinations and measurements - Switching time

ICS
33.180.20
CCS
发布
2019-09-20
实施

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-21: Examinations and measurements - Switching time

ICS
33.180.20
CCS
发布
2019-09-20
实施

本标准规定了海底光中继器的技术规范,包括有关的术语和定义、基本要求、技术要求、试验方法、检验规则及标志、运输与贮存、质量承诺和环境保护等。

Technical Requirement for Submarine Repeater

ICS
33.180.20
CCS
C359
发布
2019-08-19
实施
2019-08-19

What is BS EN 50411-3-4 - Protective housings about? BS EN 50411 is a series on fibre management systems (FMS) and protective housings to be used in optical fibre communication systems. A fibre management system manages  fibre  connections from outside of the fibre rack to the fibre routers. BS EN 50411-3-4 contains the dimensional, optical, mechanical, and environmental performance requirements of a fully installed optical fibre wall or pole-mounted box, for it to be categorized as a European Standard product. The typical configuration is splicing of incoming fibres to optional splitters and/or to pigtails, connecting pigtail plugs on one side to patch-cord plugs on the other side, using adapters. BS EN 50411-3-4 specifies the number of splice trays and splice/connector capacity for each fibre separation level. The maximum capacity is 144 connectors and splices. For housings with the highest number of splices and connectors, EN 50411-4-1 (street cabinets) can be used. Who is BS EN 50411-3-4 - Protective housings for ? BS EN 50411-3-4 on fibre management systems is useful for: Telecommunication equipment manu...

Fibre management systems and protective housings to be used in optical fibre communication systems. Product specifications - Wall box for splice to patchcord connections, for category C and A

ICS
33.180.20
CCS
发布
2019-07-31
实施
2019-07-31

What is BS EN IEC 62148 ‑ 19 - Photonic chip-scale package about?    BS EN IEC 62148 is a series on fibre optic active components and devices. Active devices are electronic components made up of semiconductor materials that actively manipulate electrons to perform the intended function. The purpose of BS EN IEC 62148 ‑ 19 is to specify adequately the physical requirements of optical transmitters and receivers that will enable the mechanical interchangeability of transmitters and receivers.   Who is BS EN IEC 62148 ‑ 19 - Photonic chip-scale package for?   BS EN IEC 62148 ‑ 19 on fibre optic active components and devices is useful for:

Fibre optic active components and devices. Package and interface standards - Photonic chip scale package

ICS
33.180.20
CCS
发布
2019-07-31
实施
2019-07-31

IEC 62148-19: 2019 covers the photonic chip scale package. The purpose of this document is to specify adequately the physical requirements of optical transmitters and receivers that will enable mechanical interchangeability of transmitters and receivers. Keywords: physical interface for photonic chip scale packages

Fibre optic active components and devices - Package and interface standards - Part 19: Photonic chip scale package

ICS
33.180.20
CCS
发布
2019-07-05
实施
2019-09-06 (7)

What is BS EN IEC 61754-7-3 - Passive components about? BS EN IEC 61754 is a series on fibre optic interconnecting devices and passive components. The broad variety of passive optical components applications include multichannel transmission, distribution, optical taps for monitoring, pump combiners for fiber amplifiers, bit-rate limiters, optical connects, route diversity, polarization diversity, interferometers, and coherent communication. BS EN IEC 61754-7-3 defines the standard interface dimensions for type MPO family of connectors with two rows of 16 fibres. BS EN IEC 61754-7-3 defines the parent connector for type MPO connector family that is a multiway plug characterized by a rectangular ferrule normally 6,4 mm × 2,5 mm which utilizes two pins of 0,55 mm diameter as its alignment. Who is BS EN IEC 61754-7-3 - Passive components for ? BS EN IEC 61754-7-3 on fibre optic interconnecting devices and passive components is useful for: Telecommunication component manufacturers Design engineers Quality control personnel Research and development facilities Why should you use BS ...

Fibre optic interconnecting devices and passive components. Fibre optic connector interfaces - Type MPO connector family. Two fibre rows 16 fibre wide

ICS
33.180.20
CCS
发布
2019-06-30
实施
2019-06-30

1.1 Product definition This European Standard contains the dimensional, optical, mechanical and environmental performance requirements of a fully installed optical fibre wall box, in order for it to be categorized as an EN standard product. The typical configuration is splicing of incoming fibres to optional splitters and/or to pigtails, connecting pigtails plugs on one side to patchcord plugs on the other side, using adapters. A wall box is a protective housing containing a fibre management system with splice trays of various fibre separation levels and connector mounting plates. The wall box may contain one or more of the following: storage and routing of fibre and cable; - uncut fibre cable storage; - splice trays; - adaptors and connectors; - passive optical devices (optical splitters or WDM). A wall box can be installed on a vertical indoor or outdoor surface above ground level. If the wall box is required to be relocatable with cables attached, the following additional tests shall be performed: - cable bending; - cable torsion. This document specifies the number of splice trays and splice/connector capacity for each fibre separation level. The maximum capacity is 144 connectors and splice. For housings with a higher number of splices and connectors the document prEN 50411 4 1 (Cabinets) should be used. Wall boxes for fibre splices only are covered in EN 50411 3 1:2012. 1.2 Operating environment The tests selected, combined with the severity and duration, and are representative of indoor and outside plant for above ground environments defined by: EN 61753 1 Ed2 (20xx): - category C: Controlled (indoor) environment; - category A: Aerial (above ground) environment. 1.3 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this European Standard does not guarantee the reliability of the product. This should be predicted using a recognized reliability assessment programme. 1.4 Quality assurance Compliance with this European Standard does not guarantee the manufacturing consistency of the product. This should be maintained using a recognized quality assurance programme. 1.5 Allowed fibre and cable types This wall box standard accommodates EN 60793 2 50 single-mode fibres and EN 60793 2 10 A1a and A1b multimode fibres and all EN 60794 series optical fibre cables with various fibre capacities, types and designs as long as fitting in the cabinet does not contravene the fibre or cable minimum bend radius.

Fibre management systems and protective housings to be used in optical fibre communication systems - Product specifications - Part 3-4: Wall box for splice to patchcord connections, for category C and A

ICS
33.180.20
CCS
发布
2019-06-28
实施
2019-11-20 (7)

Fiber optic interconnecting devices and passive components -- Basic test and measurement procedures -- Part 1: General and guidance

ICS
33.180.20
CCS
L23
发布
2019-06-20
实施

What is BS EN 50377 ‑ 18-1 about?    BS EN 50377 ‑ 18-1 contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements (excluding electrical requirements) to be met by a 12-fibre multimode PPS MPO plug terminated on EN 60793-2-10 category A1a.3a or A1a.3b fibre and a 4+4x10,3125 Gb/s MPO (QSFP) transceiver to meet in order to be categorized as an EN standard product.   Who BS EN 50377 ‑ 18 ‑ 1 for?  

Connector sets and interconnect components to be used in optical fibre communication systems. Product specifications - Type 4+4x10.3125 Gb/s MPO (QFSP) transceiver mated with an MPO connector equipped with 12 fibre PPS ferrules terminated on EN…

ICS
33.180.20
CCS
发布
2019-05-31
实施
2019-05-31

IEC 61300-2-46:2019 is available as IEC 61300-2-46:2019 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61300-2-46:2019 describes a test to determine the suitability of a fibre optic device to withstand the environmental condition of high humidity and change of temperature which can occur in actual use, storage and/or transport. The test is primarily intended to determine the suitability of fibre optic components under conditions of high humidity – combined with cyclic temperature changes and, in general, producing condensation on the surface of the device under test (DUT). Absorption of moisture can result in swelling that would destroy functional utility, cause loss of physical strength, and cause changes in other important mechanical properties. Degradation of optical properties can also occur. Although not necessarily intended as a simulated tropical test, this test can, nevertheless, be useful in determining moisture absorption of insulating or covering materials. This second edition cancels and replaces the first edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) complete revision to harmonize with IEC 60068-2-30; b) addition of detail description Clause 4, General description; c) addition of detail description Clause 5, Apparatus; d) addition of detail description Clause 6, Procedure. Keywords: suitability of fibre optic devices to withstand the environmental condition

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-46: Tests - Damp heat, cyclic

ICS
33.180.20
CCS
发布
2019-05-10
实施
2019-07-22 (7)

This part of IEC 62148 covers the photonic chip scale package. The purpose of this document is to specify adequately the physical requirements of optical transmitters and receivers that will enable mechanical interchangeability of transmitters and receivers.

Fibre optic active components and devices - Package and interface standards - Part 19: Photonic chip scale package

ICS
33.180.20
CCS
发布
2019-05-02
实施
2019-05-04

Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7-3: Type MPO connector family - Two fibre rows 16 fibre wide

ICS
33.180.20
CCS
发布
2019-04-05
实施

Optical isolators -- Part 2: Test methods

ICS
33.180.20
CCS
M33
发布
2019-03-20
实施

Fiber optic switches -- Part 2: Test Methods

ICS
33.180.20
CCS
M33
发布
2019-03-20
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved