93.030 外部污水排放系统 标准查询与下载



共找到 513 条与 外部污水排放系统 相关的标准,共 35

Fibre cement pipes for drains and sewers - Part 2: Manholes and inspection chambers; German version EN 588-2:2001

ICS
93.030
CCS
Q81
发布
2002-05
实施

Fibre-cement pipes for sewers and drains - Manholes and inspection chambers

ICS
93.030
CCS
Q81
发布
2002-04-03
实施
2002-04-03

What is BS EN 588-2 - fibre-cement manholes and inspection chambers about?      Fibre cement evolved as an alternative for asbestos-based cement. BS EN 588-2 is the second part of the ‘Fibre cement pipes for drains and sewers’ multi-series, and gives specifications for asbestos-free fibre-cement manholes and inspection chambers for use in buried drains and sewers with gravity flow at atmospheric pressure.   Note: Complete manholes or prefabricated elements may also be used for other purposes such as pumping stations, items of drainage, items for sewage treatment, or sewage disposal when corresponding additional requirements according to the relevant European Standards are fulfilled.  Who is BS EN 588-2 - fibre-cement manholes and inspection chambers fo...

Fibre-cement pipes for sewers and drains - Manholes and inspection chambers

ICS
93.030
CCS
发布
2002-04-03
实施
2002-04-03

This Part of EN 13244 specifies the characteristics of the fitness for purpose of the assembled piping systems intended for buried and above-ground pressure systems for water for general purposes, drainage and sewerage. It is also applicable for vacuum sewer systems. NOTE 1 Water for general purposes is not intended for human consumption and components conforming to this standard should not be used in systems conveying water for human consumption. For PE components intended for the conveyance of water intended for human consumption and raw water prior to treatment, see EN 12201[5]. It also specifies the test parameters for the test methods referred to in this standard. In conjunction with other Parts of EN 13244 (see Foreword), it is applicable to PE pipes, fittings, valves, their joints and to joints with components of other materials intended to be used as follows: — buried in the ground; — sea outfalls; — laid in water; — above-ground, including pipes suspended below bridges; — a maximum operating pressure, MOP, up to and including 25 bar; — an operating temperature of 20 ℃ as a reference temperature. NOTE 2 For applications operating at constant temperatures greater than 20 ℃ and up to 40 ℃, see annex A of EN 13244-1:2002. EN 13244 covers a range of maximum operating pressures and gives requirements concerning colours and additives. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes. note:1) 1 bar = 10N/m.

Plastics piping systems for buried and above-ground pressure systems for water for general purposes,drainage and sewerage - Polyethylene (PE) - Part 5:Fitness for purpose of the system

ICS
93.030
CCS
发布
2002-01-01
实施
2002-01-01

This Part of EN 13244 specifies the general aspects of polyethylene (PE) piping systems intended for buried and above-ground pressure systems for water for general purposes, drainage and sewerage. It is also applicable for vacuum sewer systems. NOTE 1 Water for general purposes is not intended for human consumption and components conforming to this standard should not be used in systems conveying water for human consumption. For PE components intended for the conveyance of water intended for human consumption and raw water prior to treatment, see EN 12201. It also specifies the test parameters for the test methods referred to in this standard. In conjunction with other Parts of EN 13244 (see Foreword), it is applicable to PE pipes, fittings, valves, their joints and to joints with components of other materials intended to be used under the following conditions: — buried in the ground; — sea outfalls; — laid in water; — above-ground, including pipes suspended below bridges; — a maximum operating pressure, MOP, up to and including 25 bar1); — an operating temperature of 20 ℃ as a reference temperature. NOTE 2 For applications operating at constant temperatures greater than 20 ℃ and up to 40 ℃, see annex A. EN 13244 covers a range of maximum operating pressures and gives requirements concerning colours and additives. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes. note: 1) 1 bar=10 N/m.

Plastics piping systems for buried and above-ground pressure systems for water for general purposes,drainage and sewerage - Polyethylene (PE) - Part 1:General

ICS
93.030
CCS
发布
2002-01-01
实施
2002-01-01

A presente Norma Europeia estabelece os requisitos de desempenho dos sistemas de drenagem de águas residuais domésticas com funcionamento em press?o negativa, independentemente dos materiais constituintes. Inclui características de desempenho adicionais que s?o relevantes para as entidades contratantes, os projectistas, os construtores e os operadores dos sistemas de drenagem de águas residuais com funcionamento em vácuo. N?o estabelece requisitos sobre a avalia??o da conformidade dos sistemas. A presente Norma Europeia fornece indica??es relativas ao projecto e à constru??o dos sistemas de drenagem de águas residuais com funcionamento em vácuo destinados ao transporte de águas residuais domésticas mas n?o de águas pluviais. N?o abrange os sistemas prediais de drenagem com funcionamento em vácuo. Os componentes do sistema dever?o ser avaliados em conformidade com a respectiva norma de produto. Na ausência de uma norma de produto, a presente Norma poderá ser utilizada como referência para a elabora??o de uma especifica??o de produto. Os requisitos de projecto estabelecidos pela presente Norma Europeia s?o requisitos mínimos e n?o constituem por si só um manual de projecto suficientemente abrangente capaz de assegurar o funcionamento correcto do sistema. Cada sistema deve ser dimensionado individualmente, com base nos par?metros de projecto do tipo de sistema utilizado; nos casos em que sejam utilizados sistemas de marca, dever?o ter-se em conta as indica??es dos fornecedores desses sistemas.

Vacuum sewerage systems outside buildings

ICS
93.030
CCS
发布
2002-01
实施
2002-01

This Part of EN 13244 specifies the characteristics of the fitness for purpose of the assembled piping systems intended for buried and above-ground pressure systems for water for general purposes, drainage and sewerage. It is also applicable for vacuum sewer systems. NOTE 1 Water for general purposes is not intended for human consumption and components conforming to this standard should not be used in systems conveying water for human consumption. For PE components intended for the conveyance of water intended for human consumption and raw water prior to treatment, see EN 12201[5]. It also specifies the test parameters for the test methods referred to in this standard. In conjunction with other Parts of EN 13244 (see Foreword), it is applicable to PE pipes, fittings, valves, their joints and to joints with components of other materials intended to be used as follows: — buried in the ground; — sea outfalls; — laid in water; — above-ground, including pipes suspended below bridges; — a maximum operating pressure, MOP, up to and including 25 bar; — an operating temperature of 20 ℃ as a reference temperature. NOTE 2 For applications operating at constant temperatures greater than 20 ℃ and up to 40 ℃, see annex A of EN 13244-1:2002. EN 13244 covers a range of maximum operating pressures and gives requirements concerning colours and additives. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes. note:1) 1 bar = 10N/m.

Plastics piping systems for buried and above-ground pressure systems for water for general purposes,drainage and sewerage - Polyethylene (PE) - Part 5:Fitness for purpose of the system

ICS
93.030
CCS
发布
2002
实施
2002

This Part of EN 13244 specifies the general aspects of polyethylene (PE) piping systems intended for buried and above-ground pressure systems for water for general purposes, drainage and sewerage. It is also applicable for vacuum sewer systems. NOTE 1 Water for general purposes is not intended for human consumption and components conforming to this standard should not be used in systems conveying water for human consumption. For PE components intended for the conveyance of water intended for human consumption and raw water prior to treatment, see EN 12201. It also specifies the test parameters for the test methods referred to in this standard. In conjunction with other Parts of EN 13244 (see Foreword), it is applicable to PE pipes, fittings, valves, their joints and to joints with components of other materials intended to be used under the following conditions: — buried in the ground; — sea outfalls; — laid in water; — above-ground, including pipes suspended below bridges; — a maximum operating pressure, MOP, up to and including 25 bar1); — an operating temperature of 20 ℃ as a reference temperature. NOTE 2 For applications operating at constant temperatures greater than 20 ℃ and up to 40 ℃, see annex A. EN 13244 covers a range of maximum operating pressures and gives requirements concerning colours and additives. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national guidance or regulations and installation practices or codes. note: 1) 1 bar=10 N/m.

Plastics piping systems for buried and above-ground pressure systems for water for general purposes,drainage and sewerage - Polyethylene (PE) - Part 1:General

ICS
93.030
CCS
发布
2002
实施
2002

This European Standard specifies performance requirements as defined in Table 1 and describes test methods for precast concrete units for inspection chambers designed to be used for inverts not exceeding 2 metres deep and manholes, of circular, rectangular (with or without chamfered or rounded corners) or elliptical internal shape, unreinforced, steel fibre and reinforced, with nominal sizes and normal length not exceeding DN 1 250 (circular) or LN 1 250 (rectangular or elliptical).The intended use is to permit access to, and to allow aeration of, drain or sewer systems forThe conveyance of sewage, rainwater and surface water under gravity or occasionally at low head of pressure, mainly installed in areas subjected to vehicular and/or pedestrian traffic. Requirements for joints (elastomeric, plastomeric or other sealing materials,This European Standard specifies performance requirements as defined in Table 1 and describes test methods for precast concrete units for inspection chambers designed to be used for inverts not exceeding 2 metres deep and manholes, of circular, rectangular (with or without chamfered or rounded corners) or elliptical internal shape, unreinforced, steel fibre and reinforced, with nominal sizes and normal length not exceeding DN 1 250 (circular) or LN 1 250 (rectangular or elliptical).The intended use is to permit access to, and to allow aeration of, drain or sewer systems forThe conveyance of sewage, rainwater and surface water under gravity or occasionally at low head of pressure, mainly installed in areas subjected to vehicular and/or pedestrian traffic. Requirements for joints (elastomeric, plastomeric or other sealing materials, either integrated inThe unit or supplied separately) are also specified.This European Standard specifies performance requirements as defined in Table 1 and describes test methods for precast concrete units for inspection chambers designed to be used for inverts not exceeding 2 metres deep and manholes, of circular, rectangular (with or without chamfered or rounded corners) or elliptical internal shape, unreinforced, steel fibre and reinforced, with nominal sizes and normal length not exceeding DN 1 250 (circular) or LN 1 250 (rectangular or elliptical).The intended use is to permit access to, and to allow aeration of, drain or sewer systems forThe conveyance of sewage, rainwater and surface water under gravity or occasionally at low head of pressure, mainly installed in areas subjected to vehicular and/or pedestrian traffic. Requirements for joints (elastomeric, plastomeric or other sealing materials, either integrated inThe unit or supplied separately) are also specified.

Concrete manholes and inspection chambers, unreinforced, steel fibre and reinforced

ICS
93.030
CCS
发布
2002
实施

Esta Norma Europeia aplica-se aos sistemas públicos de drenagem de águas residuais que funcionam principalmente com escoamento em superfície livre, desde o local em que as águas residuais deixam o edifício ou o sistema de drenagem da cobertura, ou entram numa sarjeta ou sumidouro, até ao local em que s?o descarregadas numa instala??o de tratamento ou num meio receptor. Os ramais e os colectores situados sob edifícios consideram-se também incluídos, desde que n?o fa?am parte do sistema de drenagem predial. Esta Norma Europeia estabelece os princípios gerais relativos à explora??o e à manuten??o dos sistemas de drenagem de águas residuais.

Drain and sewer systems outside buildings Part 7:Maintenance and operations

ICS
93.030
CCS
发布
2001-12
实施
2001-12

1.1 This specification describes material and physical requirements for nonrigid poly (vinyl chloride) (PVC) preformed molded and spliced gaskets used in mechanical couplings. These couplings are used in gravity flow drain, waste, and vent (DWV), sewer, sanitary, and storm plumbing systems. They include couplings to join similar and dissimilar piping sizes and piping material. 1.2 Recycled materials may be used in this product in accordance with the requirements in Section 4. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are given for information only. Note 18212;There are no ISO standards covering the primary subject matter of this specification. 1.4 The following safety hazards caveat pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Standard Specification for Poly (Vinyl Chloride) (PVC) Gaskets for Drain, Waste, and Vent (DWV), Sewer, Sanitary, and Storm Plumbing Systems

ICS
93.030
CCS
发布
2001-11-10
实施

1. Domaine d'application 1.1 Cette norme établit les exigences minimales en matière de conception et de matériaux, de méthodes de fabrication et de marquage des fosses septiques et des bassins de rétention préfabriqués, ainsi que des compartiments d'effluent faits en acier, en béton, en plastique renforcé de fibres de verre ou en polyéthylène, destinés à recevoir les eaux usées ou leur effluent. 1.2 Cette norme ne prétend pas aborder l'ensemble des questions de sécurité reliées à son utilisation. La responsabilité incombe donc à l'utilisateur d'établir les règles de santé et de sécurité appropriées, et de déterminer préalablement l'applicabilité des restrictions réglementaires afférentes. Cette norme ne s'applique pas aux bassins de rétention destinés aux véhicules de camping ; consulter à cet effet la norme CSA B45.6. 1.3 L'appendice A illustre les aménagements caractéristiques des fosses septiques ainsi que la terminologie pertinente. Les dessins ne visent pas à proposer des matériaux, des méthodes ni des critères de conception.

Septic tanks and prefabricated retention basins

ICS
93.030
CCS
发布
2001-10-01
实施

General requirements for components used for renovation and repair of drain and sewer systems outside buildings; German version EN 13380:2001

ICS
93.030
CCS
P41
发布
2001-10
实施

This European Standard specifies general requirements and general test methods for components such as pipes and fittings with their respective joints, manholes, inspection chambers and materials such as mortar and chemicals all intended to be used for repair and renovation of drain and sewer systems. These drain and sewer systems generally operate as gravity drainage systems where any pressure likely to occur is a maximum of 40 kPa and which are generally buried. This European Standard provides the general basis for the preparation and revision of voluntary product standards. It is not applicable for evaluation of products. It applies as a reference for dra

General requirements for components used for renovation and repair of drain and sewer systems outside buildings

ICS
93.030
CCS
发布
2001-09-11
实施
2001-08-10

General requirements for components used for renovation and repair of drain and sewer systems outside buildings.

ICS
93.030
CCS
P41
发布
2001-09-01
实施
2001-09-05

This European Standard specifies general requirements and general test methods for: — components such as pipes and fittings with their respective joints, manholes, inspection chambers; and — materials such as mortar and chemicals all intended to be used for repair and renovation of drain and sewer systems. These drain and sewer systems generally operate as gravity drainage systems where any pressure likely to occur is a maximum of 40 kPa and which are generally buried. This European Standard provides the general basis for the preparation and revision of voluntary product standards. It is not applicable for evaluation of products. It applies as a reference for drawing up a product specification, if there is no product standard available. This European Standard includes quality control and optional certification requirements. It applies to components those used in systems that convey in a satisfactory manner: — domestic waste water; — rainwater and surface water; and — other waste waters (e.g. industrial waste water) that will not damage the components. This European Standard applies to components of circular and other cross-sections. This European Standard applies equally to components that are factory-made and to those manufactured on site, where applicable.

General requirements for components used for renovation and repair of drain and sewer systems outside buildings

ICS
93.030
CCS
P41
发布
2001-07-15
实施
2001-07-15

Esta Norma Europeia aplica-se aos sistemas públicos de drenagem de águas residuais que funcionam principalmente com escoamento em superfície livre, desde o local em que as águas residuais deixam o edifício ou o sistema de drenagem da cobertura, ou entram numa sarjeta ou sumidouro, até ao local em que s?o descarregadas numa instala??o de tratamento ou num meio receptor. Os ramais e os colectores situados sob edifícios consideram-se também incluídos, desde que n?o fa?am parte do sistema de drenagem predial. Esta parte da Norma estabelece os princípios e os procedimentos para a concep??o e o dimensionamento dos trabalhos de reabilita??o necessários para se atingirem os níveis de desempenho prescritos para os sistemas existentes de águas residuais.

Drain and sewer systems outside buildings Part 5:Rehabilitation

ICS
93.030
CCS
发布
2001-07
实施
2001-07

This European Standard specifies general requirements and general test methods for:,一components such as pipes and fittings withTheir respective joints, manholes, inspection chambers; and一materials such as mortar and chemicals all intended to be used for repair and renovation of drain and sewer systems.These drain and sewer systems generally operate as gravity drainage systems where any pressure likely tooccur is a maximum of 40 kPa and which are generally buried.This European Standard providesThe general basis forThe preparation and revision of voluntary productstandards. It is not applicable for evaluation of products.It applies as a reference for drawing up a product specification, ifThere is no product standard available.This European Standard includes quality control and optional certification requirements.

General requirements for components used for renovation and repair of drain and sewer systems outside buildings

ICS
93.030
CCS
发布
2001-05-01
实施

1 Aspectos gerais A presente Norma Europeia estabelece os requisitos de desempenho, projecto, funcionamento, manuten??o e instala??o, assim como verifica??es e métodos de ensaio, dos sistemas públicos de drenagem de águas residuais com funcionamento sob press?o positiva. N?o estabelece requisitos sobre a avalia??o da conformidade dos sistemas com a presente Norma Europeia. N?o especifica os detalhes de projecto nem os materiais de constru??o dos diferentes componentes do sistema. A presente Norma Europeia abrange os sistemas de drenagem de águas residuais com funcionamento sob press?o positiva destinados ao transporte de águas residuais definidas como: águas residuais domésticas provenientes de habita??es e de instala??es comerciais mas excluindo as águas pluviais. A presente Norma Europeia abrange o projecto de um sistema de drenagem de águas residuais com funcionamento sob press?o e estabelece alguns requisitos relativos aos produtos utilizados, a fim de assegurar o funcionamento do sistema. Os componentes do sistema dever?o ser avaliados através da correspondente norma de produto. Na ausência de uma norma de produto, a presente Norma poderá ser utilizada como referência para a elabora??o de uma especifica??o para esse produto. 2 Limites de projecto equipamento intermédi de sobrepress?o n?o é abrangido pela presente Norma. A utiliza??o de ar comprimido como o único meio gerador de press?o n?o é abrangida pela presente Norma. Os requisitos de projecto estabelecidos pela presente Norma s?o requisitos mínimos e n?o constituem por si só um manual de projecto suficientemente abrangente capaz de assegurar o funcionamento correcto do sistema. Cada sistema deve ser dimensionado individualmente. Nos casos em que sejam utilizados componentes de marca, dever?o ter-se em conta as indica??es do fornecedor.3 Aplica??es dos sistemas de drenagem de águas residuais com funcionamento sob press?o Informa??es relativas à utiliza??o dos sistemas de drenagem de águas residuais com funcionamento sob press?o s?o apresentadas em A.l. 4 Fontes de informa??o complementar Documentos que, embora relativos a sistemas específicos, contêm detalhes que podem ser utilizados no ?mbito da presente Norma, s?o apresentados no Anexo C (informativo).

Pressure sewerage systems outside buildings

ICS
93.030
CCS
发布
2001-02
实施
2001-02

Modified or close-fit slip-lining techniques involve inserting a thermoplastic tube into the host pipe, which has been temporarily deformed to allow sufficient clearance for insertion. When the tube is subsequently returned to its approximate original s

Rehabilitation of Water Mains

ICS
93.030
CCS
Q81
发布
2001-01-01
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号