赛默飞Thermo IonPac AS14A Carbonate Eluent Anion-Exchange Column离子色谱IC柱

赛默飞Thermo IonPac AS14A Carbonate Eluent Anion-Exchange Column离子色谱IC柱

产品参数

货号 规格 操作
更多货号咨询>>
关闭

服务地域:全国

属性:产地:美国; 品牌:赛默飞 ;货期:现货

上海希言科学仪器有限公司

普通会员 普通会员
推荐产品推荐产品
产品描述产品描述

Fast Analysis of the Common Inorganic Anions in Diverse Sample Matrices

The IonPac®AS14A anion-exchange column is a carbonate-based column for fast analysis of the common inorganic anions in diverse sample matrices. The AS14A meets the performance requirements specified in US EPA Method 300.0 (A).

  • High efficiency and fast analysis (8 minutes)

  • High-capacity applications (13 minute run time)

  • Improved peak shape, efficiency, and pH stability

  • Meets or exceeds US EPA Method 300.0 (A) performance requirements

  • Simplified operation with AS14A Eluent Concentrate and Combined Seven Anion Standard

The AS14A is designed for the separation of inorganic anions, including fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate, using a carbonate/bicarbonate eluent coupled with suppressed conductivity detection. The inorganic anions can easily be determined in drinking water, wastewater, foods and beverages, scrubber solutions, and other diverse sample matrices.

For simplified operation use the AS14A with AS14A Eluent Concentrate and the Combined Seven Anion Standard. Use the ASRS 300 suppressor with the AS14A column for low-noise operation.

Note: See also the IonPac AS22, the newest carbonate eluent column recommended for fast analysis of inorganic anions.

Dionex IonPac AS14A Anion-Exchange Column Specifications
DimensionsDionex IonPac AS14A Analytical Column:
3×150 mm and 4×250 mm
Dionex IonPac AG14A Guard Column:
3×30 mm and 4×50 mm
Maximum operating pressure27.6 MPa (4000 psi)
Mobile phase compatibilitypH 0–14; 0–100% HPLC solvents
Substrate characteristicsBead Diameter: 7 µm (4 × 250 mm); 5 µm (3 × 150 mm)
Pore Size: 100 Å
Cross-Linking (%DVB): 55%
Functional group characteristicsIon-Exchange Group: Surface-functionalized alkyl quaternary ammonium ion Hydrophobicity: Medium High
Capacity40 µeq (3×150 mm analytical column)
120 µeq (4×250 mm analytical column)
Column constructionPEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.



Determination of inorganic anions in a wastewater sample from a chemical manufacturer on an IonPac®AS14A-5µm (3 × 150 mm) column.

Determination of inorganic anions in municipal drinking water on the IonPac®AS14A-5µm (3 × 150 mm) column.

Determination of anionic additives in toothpaste on an IonPac®AS14A- 5µm (3 × 150 mm) column.

Hydroxide Gradient Separation of Inorganic and Organic Anions Using the IonPac®AS14A Column.


Analytical
IonPac AS14A-5 µm Analytical Column (3 x 150 mm)056901
IonPac AS14A-7 µm Analytical Column (4 x 250 mm)056904
Guard Columns
IonPac AG14A-7 µm Guard Column (4 x 50 mm)056897
IonPac AG14A-5 µm Guard Column (3 x 30 mm)056899