75.200 石油、石油产品和天然气储运设备 标准查询与下载



共找到 1114 条与 石油、石油产品和天然气储运设备 相关的标准,共 75

本文件规定了石化装置承压类特种设备集中检验管理的通用要求、组织实施、问题隐患整改、报告出具、安全管理及质量管理。 本文件适用于石化装置一次性集中检验锅炉、压力容器和压力管道总数不少于 500 台(条)的管理。

Specifications for centralized inspection and management of pressure-bearing special equipment in petrochemical plants

ICS
75.200
CCS
E98
发布
2024-03-19
实施
2024-03-21

BS EN ISO 12747 Oil and gas industries including lower carbon energy - Pipeline transportation systems -Recommended practice for pipeline life extension

ICS
75.200
CCS
发布
2024-03-15
实施
2024-03-15

Oil and gas industries including lower carbon energy. Cathodic protection of pipeline transportation systems - Offshore pipelines

ICS
75.200
CCS
发布
2024-02-29
实施
2024-02-29

Standard Practice for Performing Visual Examination of Containment Sumps

ICS
75.200
CCS
发布
2024-02-01
实施

本文件规定了工厂预制袖管三通的术语和定义、购方应提供的信息、代号、设计、制造、检验和试验、标志、包装、运输和文件和资质要求等。 本文件适用于设计压力不高于15MPa、公称直径不大于DN1400的油气长输管道工程用工厂预制袖管三通。油气田地面工程集输用预制袖管三通可参照使用。

Factory prefabricated tee with sleeves for oil and gas pipeline projects

ICS
75.200
CCS
G520
发布
2024-01-17
实施
2024-04-17

Petroleum, petrochemical and natural gas industries — Cathodic protection of pipeline systems — Part 1: On-land pipelines

ICS
75.200
CCS
发布
2023-12-22
实施

本文件规定了煤层气湿式储气柜超高自动放散工艺规范的术语和定义、储气柜要求、工艺要求、安全管理、工艺流程、应急措施和处理、检查维护。 本文件适用于煤层气湿式储气柜超高自动放散工艺的推广和应用。

Technical specifications for ultra-high automatic dispersion of coal bed methane wet gas holders

ICS
75.200
CCS
D451
发布
2023-12-08
实施
2023-12-23

本文件规定了煤层气储气柜排空置换技术规程的术语和定义、储气柜要求、安全管理、操作流程、气体处理和管道管理、检修与维护保养。 本文件适用于煤层气储气柜排空置换技术的推广和应用。

Technical regulations for emptying and replacing coalbed methane gas storage cabinets

ICS
75.200
CCS
D451
发布
2023-12-08
实施
2023-12-23

1 Scope 1.1 Inclusions This Code applies to a) the design, location, construction, operation, operator training, and maintenance of CNG vehicle refuelling stations; and b) CNG bulk transport filling and decanting stations, including i) those that are fixed or mobile and intended for private or public dispensing operations; and ii) bulk transport filling and decanting stations that feed CNG pressure reduction stations or other non-vehicle uses. 1.2 Exclusions This Code does not apply to a) refuelling vehicles with liquefied natural gas (LNG), which is covered by CSA B108.2. However, when an LNG facility has capacity for CNG vehicle refuelling from a liquid to compressed natural gas system (L/CNG system), this Code applies to facilities downstream of the L/CNG system odourizer’s outlet isolation valve; b) transfer of CNG from the CNG vehicle fuel storage system of one vehicle to the CNG vehicle fuel storage system of another vehicle; c) listed residential fuelling appliances (RFAs), listed non-residential vehicle fuelling appliances (VFAs), and listed vehicle refuelling appliances (VRAs), except where i) the aggregate flow capacity of a connected refuelling appliance (RA), or a combination of refuelling appliances thereof, exceeds 0.850 Sm3/min (30 SCFM); or ii) the RA is connected to storage, in which case coverage applies to the storage and dispensing system starting at the outlet of the individual RA (see Figure D.1); and d) mobile equipment containing compressed natural gas, such as MRUGs, PRUGs, and bulk containers in the act of being transported or offered for transport in accordance with Transport Canada’s Transportation of Dangerous Goods Act and Regulations. 1.3 Pressure terminology Unless otherwise specified, all references to pressure throughout this Code are to be considered gauge pressures. 1.4 Terminology In this Code, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Code; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Code. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Use of SI units The values given in SI units are the units of record for the purposes of this Code. The values given in parentheses are for information and comparison only. Notes: 1) IEEE/ASTM SI 10 or ISO 80000-1 can be used as a guide when converting U.S. customary units to SI units. 2) Where the abbreviation “gal” is used in this Code, it indicates a U.S. gallon equivalent to 3.785 L water capacity. 3) This Code was originally developed using the U.S. customary system of measurement and subsequently converted to SI units having three significant digits. Every attempt has been made to provide accurate conversion values; however, when designing systems using these values, engineering judgment should be applied.

Compressed natural gas refuelling stations installation code

ICS
75.200
CCS
发布
2023-12-01
实施

Standard Practice for Liquefied Natural Gas (LNG) Bunkering Hose Transfer Assembly

ICS
75.200
CCS
发布
2023-12-01
实施

1 Scope 1.1 Inclusions This Code applies to a) the design, location, construction, operation, operator training, and maintenance of LNG refuelling stations; b) LNG mobile refuelling units (MRUL) or LNG portable refuelling units (PRUL) with single containment storage tanks up to 265 m3 (70 000 gal) water capacity employed for vehicle LNG dispensing operations; c) shop-fabricated and assembled refuelling stations when used to receive and store LNG to dispense LNG into vehicle fuel tanks; and d) the LNG portion of stations that vapourize and pressurize LNG to obtain CNG, up to and including the odourizer’s outlet isolation valve. Note: When a refuelling station dispenses fuels in addition to LNG, this Code applies only to the LNG refuelling system and equipment. 1.2 Exclusions This Code does not apply to a) indoor refuelling; b) marine vessel LNG fuelling facilities; c) rail locomotive LNG fuelling facilities; d) equipment, piping, or tubing downstream of the L/CNG system odourizer’s outlet isolation valve (see CSA B108.1); e) CNG equipment including storage, compression, and/or dispensing equipment; f) CNG mobile refuelling units (MRUG) or CNG portable refuelling units (PRUG); g) equipment, piping, or tubing downstream of the gas pressure regulator for closed boil-off gas systems; h) dispensing of LNG other than into vehicle or cargo fuel tanks; i) liquefaction equipment; j) LNG engine fuel systems; k) LNG and CNG repair garages; l) underground piping or tubing for LNG; m) LNG storage tanks, pumps, and process piping or tubing when an LNG refuelling station is sharing the LNG plant storage tank; and n) transfer of LNG from the LNG vehicle fuel storage system of one vehicle to the LNG vehicle fuel storage system of another vehicle. Note: This does not apply to a bulk fuel storage system. 1.3 Pressure terminology Unless otherwise specified, all references to pressure throughout this Code are to be considered gauge pressures. 1.4 Terminology In this Code, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Code; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Code. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 Units of measurement The values given in SI units are the units of record for the purposes of this Code. The values given in parentheses are for information and comparison only. Notes: 1) IEEE/ASTM SI 10 or ISO 80000-1 can be used as a guide when converting U.S. customary units to SI units. 2) Where the abbreviation “gal” is used in this Code, it indicates a U.S. gallon equivalent to 3.785 L water capacity. 3) This Code was developed originally using the U.S. customary system of measurement and subsequently converted to SI units having three significant digits. Every attempt has been made to provide accurate conversion values; however, when designing systems using these values, engineering judgment should be applied.

Liquefied natural gas refuelling stations installation code

ICS
75.200
CCS
发布
2023-12-01
实施

本文件规定了在役立式圆筒形钢制焊接储罐呼吸阀、紧急泄放阀、液压安全阀、氮封阀的检验内容、检验方法与合格评定准则。 本文件适用于设计压力小于0.1 MPa,盛装石油、石化产品及其他类似液体介质的在役立式圆筒形钢制焊接储罐用呼吸阀、紧急泄放阀、液压安全阀和氮封阀的检验。

Technical specification for inspection of safety accessories of vertical cylindrical steel welded storage tanks in-service

ICS
75.200
CCS
M745
发布
2023-11-20
实施
2023-11-20

本文件规定了油气管道环焊接头微区拉伸性能试验的术语和定义、取样位置、取样部位、试样尺寸、试样加工、试验设备、试验准备、试验步骤、数据处理和试验报告。 本文件适用于油气管道环焊接头适用性评价时的微区(焊缝不同位置,包含盖面焊区、填充焊区、根焊区、热影响区及母材)拉伸性能测试,也适用于储运设施等对接接头。

Mechanical properties test for microzones of oil and gas pipeline girth butt welds—Part 1: Tensile test method

ICS
75.200
CCS
G520
发布
2023-11-17
实施
2024-02-17

本文件规定了管道环焊接头不同特征区域夏比冲击韧性测试的术语和定义、试样样坯制备、缺口位置确定、试样位置确定、试样加工、试样数量、试验设备、试验、试验记录和试验报告。 本文件适用于焊缝安全评价中不同特征区域夏比冲击韧性的测试,其他焊缝也可参照执行。

Mechanical properties test for microzones of oil and gas pipeline girth butt welds—Part 2: Impact test method

ICS
75.200
CCS
G520
发布
2023-11-17
实施
2024-02-17

Scope 1.1 This Standard sets forth the minimum requirements for cover primary, secondary, and coaxial types of flexible connector pipes intended for short length transfer and containment of the specific flammable and combustible liquids (or vapors thereof) identified in this Standard, at commercial (public) or fleet (private) automotive motor vehicle fueling stations or similar fuel dispensing applications, and piping systems for fuel supply of generators, burners or similar equipment. 1.2 Flexible connector pipes may be metallic, nonmetallic, or composite, but are limited to maximum 12 ft (3.65 m) lengths in nominal sizes up to 4 in (102 mm) as flexible transition components within fuel dispensing and/or vapor recovery piping systems, typically intended for use in the following automotive fueling station applications: a) Underground use (below surface but accessible such as within chase piping) when connected to underground tanks or underground pipes with expected exposures to soil, water, and soil fluids; b) Sump use (enclosed tank, transition or dispenser types) when connected to pumps, valves, monitors, or dispensing devices with expected exposures to soil, water, soil fluids, and occasional sunlight; c) Aboveground use (above surface but with additional physical protection) when connected to aboveground tanks or aboveground pipes with expected exposures to soil, water, soil fluids, and sunlight. 1.3 Flexible connector pipes are intended for containment of automotive fuels and similar fuels or liquids under the expected use conditions, and exposures that have similar chemical, physical and material compatibility properties as represented in these requirements based on fuels formulated in accordance with 40 CFR Part 80, Regulation of Fuels and Fuel Additives, and meeting the following ASTM Fuel Specifications and blend limitations. Refer to Annex B (Informative) for a list of Standards on fuels and other liquids. 1.4 Products covered by this Standard are intended to be installed and used in accordance with: a) In the United States: 1) Flammable and Combustible Liquids Code, NFPA 30, 2) Code for Motor Fuel Dispensing Facilities and Garages, NFPA 30A, 3) Uniform Fire Code, NFPA 1, 4) International Fire Code published by the International Fire Council, or 5) Other applicable federal and state regulations for piping. b) In Canada: 1) National Fire Code of Canada; 2) CSA B139 Series, Installation Code for Oil-Burning Equipment; and 3) CCME PN 1326, Environmental Code of Practice for Aboveground and Underground Storage Tank Systems Containing Petroleum and Allied Petroleum Products. 1.5 These products are factory manufactured and intended for on-site field assembly, inspection, and leak testing for the specified applications and use conditions by qualified persons in accordance with the manufacturer's instructions and local requirements. 1.6 These products are intended to be periodically inspected and maintained for continued service, or taken out of service if necessary, by qualified persons in accordance with industry recommended practices and/or the manufacturer’s instructions. 1.7 These products have not been evaluated for use after natural disasters, fires or exposures to chemicals not representative of the test liquids or excessive physical damage beyond the expected assembly, installation and uses as identified in these requirements. 1.8 These products have not been evaluated for special use piping applications where exposed to heavy or continuous physical abuses, excessive mechanical stresses; or environments that are highly corrosive; or operate outside of the expected ambient use temperature range for significant times. 1.9 These requirements do not cover underground piping products for liquid fuels, which are found in the Standard for Nonmetallic Underground Piping for Flammable Liquids, UL 971 or Outline of Investigation for Metallic Underground Piping for Flammable Liquids, UL 971A, and ULC-S679, Standard for Metallic and Nonmetallic Underground Piping for Flammable and Combustible Liquids. 1.10 These requirements do not cover aboveground piping products for gaseous fuels (such as natural gas, liquefied petroleum gas, propane, butane, etc.), which are found in the Standard for Flexible Metallic Hose, UL 536. 1.11 These requirements do not cover fuel dispensing and vapor recovery hose, which are found in the Standard for Hose and Hose Assemblies for Dispensing Flammable and Combustible Liquids, UL 330, the Standard for Hose and Hose Assemblies for Use with Dispensing Devices for Dispensing Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0-E85), UL 330A, or the Standard for Hose and Hose Assemblies for Use With Dispensing Devices Dispensing Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends With Nominal Biodiesel Concentrations Up To 20 Percent (B20), Kerosene, and Fuel Oil, UL 330B.

Flexible Connector Piping for Flammable and Combustible Liquids

ICS
75.200
CCS
发布
2023-11-10
实施

Plastics piping systems for the supply of gaseous fuels — Unplasticized polyamide (PA-U) piping systems with fusion jointing and mechanical jointing — Part 1: General

ICS
75.200
CCS
发布
2023-11
实施
2023-11

Piping systems for rehabilitation of underground gas supply networks — Part 1: Polyethylene (PE) material

ICS
75.200
CCS
发布
2023-11
实施

Plastics piping systems for the supply of gaseous fuels - Unplasticized polyamide (PA-U) piping systems with fusion jointing and mechanical jointing — Part 6: Code of practice for design, handling and installation

ICS
75.200
CCS
发布
2023-10
实施
2023-10

Plastics piping systems for the supply of gaseous fuels — Polyethylene (PE) — Part 2: Pipes

ICS
75.200
CCS
发布
2023-10
实施

Plastics piping systems for the supply of gaseous fuels — Polyethylene (PE) — Part 1: General

ICS
75.200
CCS
发布
2023-10
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved